Paper #7 Efficiency and Reliability of Ilio Sacral Screws in Fusionless Surgery for Neuromuscular Scoliosis: Preliminary Results of 100 Patients

2016 ◽  
Vol 4 (6) ◽  
pp. 449
Author(s):  
Lotfi Miladi ◽  
Gaume Mathilde ◽  
Nejib Khouri ◽  
Christophe Glorion
2018 ◽  
Vol 6 (6) ◽  
pp. 819
Author(s):  
Lotfi Miladi ◽  
Rabih Hajj ◽  
Nejib Khouri ◽  
Christophe Glorion

2018 ◽  
Vol 45 (videosuppl1) ◽  
pp. V2 ◽  
Author(s):  
Michel Lefranc ◽  
F. François Deroussen ◽  
Richard Gouron

Fusionless surgery coupled with growing rod techniques is increasingly advocated for the treatment of early-onset scoliosis in general and neuromuscular scoliosis in particular. Iliosacral screws have excellent biomechanical characteristics but are hard to place safely. Here, the authors report on robot-assisted iliosacral screw positioning as part of growing rod surgery for the fusionless correction of early-onset scoliosis. The technique is based on a bilateral double sliding rod construct anchored to the pelvis proximally with 6 hooks or sublaminar bands and distally with iliosacral screws placed by the robot.The video can be found here: https://youtu.be/5HGH_DiD-ck.


2021 ◽  
Vol 20 (3) ◽  
pp. 169-173
Author(s):  
ROBSON CRUZ DE OLIVEIRA ◽  
HELTON LUIZ APARECIDO DEFINO ◽  
HERTON RODRIGO TAVARES COSTA

ABSTRACT Objective To present the preliminary results of the bipolar technique for the surgical treatment of neuromuscular spine deformities. Methods Five patients with neuromuscular scoliosis (cerebral palsy – 3 patients, spinal amyotrophy – 1 patient, and genetic syndrome – 1 patient) underwent surgical treatment using the bipolar technique and were evaluated 12 months after the operation. Results General care and the ability to sit improved in all patients. The main curve ranged from 64.7 to 84.1 degrees (mean 70.58 ± 7.1) in the preoperative period and from 2.6 to 50.3 degrees (mean 25.50 ± 16.0) in the postoperative period with 64% correction. Corrections of pelvic obliquity (85%), T4-T12 kyphosis (43%), the Pisa angle (69%) and the sacroclavicular angle (60%) were observed 12 months following surgery. Postoperative infection (2 patients) and pneumonia (1 patient) were the complications observed. Conclusion The bipolar technique presented good clinical and radiological results associated with low morbidity in the treatment of neuromuscular spine deformities. Level of evidence IV; Case series.


1999 ◽  
Vol 173 ◽  
pp. 185-188
Author(s):  
Gy. Szabó ◽  
K. Sárneczky ◽  
L.L. Kiss

AbstractA widely used tool in studying quasi-monoperiodic processes is the O–C diagram. This paper deals with the application of this diagram in minor planet studies. The main difference between our approach and the classical O–C diagram is that we transform the epoch (=time) dependence into the geocentric longitude domain. We outline a rotation modelling using this modified O–C and illustrate the abilities with detailed error analysis. The primary assumption, that the monotonity and the shape of this diagram is (almost) independent of the geometry of the asteroids is discussed and tested. The monotonity enables an unambiguous distinction between the prograde and retrograde rotation, thus the four-fold (or in some cases the two-fold) ambiguities can be avoided. This turned out to be the main advantage of the O–C examination. As an extension to the theoretical work, we present some preliminary results on 1727 Mette based on new CCD observations.


2000 ◽  
Vol 179 ◽  
pp. 163-165
Author(s):  
S. K. Solanki ◽  
M. Fligge ◽  
P. Pulkkinen ◽  
P. Hoyng

AbstractThe records of sunspot number, sunspot areas and sunspot locations gathered over the centuries by various observatories are reanalysed with the aim of finding as yet undiscovered connections between the different parameters of the sunspot cycle and the butterfly diagram. Preliminary results of such interrelationships are presented.


1978 ◽  
Vol 48 ◽  
pp. 31-35
Author(s):  
R. B. Hanson

Several outstanding problems affecting the existing parallaxes should be resolved to form a coherent system for the new General Catalogue proposed by van Altena, as well as to improve luminosity calibrations and other parallax applications. Lutz has reviewed several of these problems, such as: (A) systematic differences between observatories, (B) external error estimates, (C) the absolute zero point, and (D) systematic observational effects (in right ascension, declination, apparent magnitude, etc.). Here we explore the use of cluster and spectroscopic parallaxes, and the distributions of observed parallaxes, to bring new evidence to bear on these classic problems. Several preliminary results have been obtained.


Author(s):  
Irwin Bendet ◽  
Nabil Rizk

Preliminary results reported last year on the ion etching of tobacco mosaic virus indicated that the diameter of the virus decreased more rapidly at 10KV than at 5KV, perhaps reaching a constant value before disappearing completely.In order to follow the effects of ion etching on TMV more quantitatively we have designed and built a second apparatus (Fig. 1), which incorporates monitoring devices for measuring ion current and vacuum as well as accelerating voltage. In addition, the beam diameter has been increased to approximately 1 cm., so that ten electron microscope grids can be exposed to the beam simultaneously.


Author(s):  
R. Varughese ◽  
S. W. Thompson ◽  
P. R. Howell

Ever since Habraken and Economopoulos first employed the term granular bainite to classify certain unconventional transformation products in continuously cooled steels, the term has been widely accepted and used, despite the lack of a clear consensus as to the detailed nature of the transformation products which constitute granular bainite. This paper presents the preliminary results of a TEM investigation of an 0.04 wt% C, copper-containing steel (designated HSLA-100). It is suggested that the term granular ferrite rather than granular bainite is a more accurate description of this multiphase reaction product.Figure 1 is a light micrograph of a sample which had been air-cooled from 900°C to room temperature. The microstructure is typical of that which has been termed granular bainite in the past and appears to consist of equiaxed ferritic grains together with other minor transformation products. In order to examine these structures in more detail, both continuously cooled and isothermally transformed and quenched materials have been examined with TEM. Granular bainite has been found in virtually all samples.


1998 ◽  
Vol 18 (3) ◽  
pp. 269-269
Author(s):  
Granerus ◽  
Ohlsson ◽  
Areskog ◽  
Andersson

Sign in / Sign up

Export Citation Format

Share Document