scholarly journals An application of mass spectrometry for quality control of biologicals: Highly sensitive profiling of plasma residuals in human plasma-derived immunoglobulin

2017 ◽  
Vol 152 ◽  
pp. 312-320 ◽  
Author(s):  
Franck Limonier ◽  
Katleen Van Steendam ◽  
Geneviève Waeterloos ◽  
Koen Brusselmans ◽  
Myriam Sneyers ◽  
...  
2019 ◽  
Vol 15 (7) ◽  
pp. 710-715
Author(s):  
S.T. Narenderan ◽  
Basuvan Babu ◽  
T. Gokul ◽  
Subramania Nainar Meyyanathan

Objective: The aim of the present work is to achieve a novel highly sensitive chromatographic method for the simultaneous determination of hepatitis C agents, sofosbuvir and velpatasvir from human plasma using ritonavir as an internal standard. Methods: Chromatographic separation was achieved using Hypersil C18 column (50mm x 4.6mm, 3μm) with an isocratic elution mode using the mobile phase composition 10 mM ammonium formate buffer (pH 5.0): acetonitrile (20:80 v/v) pumped at a flow rate of 0.5 ml/min. The detection was carried out by tandem mass spectrometry using Multiple Reaction Monitoring (MRM) positive Electrospray Ionization (ESI) with proton adducts at m/z 530.10 > 243.10, 883.40 > 114.0 and 721.25 > 197.0. Results: The method validated as per USFDA guidelines with respect to linearity, accuracy, and precision was found to be acceptable over the concentration range of 0.2–2000 ng/ml and 5-2000 ng/ml for sofosbuvir and velpatasvir respectively and the method was found to be highly sensitive and selective. Conclusion: The developed tandem mass spectrometric method is robust and can be applied for the monitoring of plasma levels of the analyzed drug in preclinical and clinical pharmacokinetic studies.


2021 ◽  
Vol 8 (2) ◽  
pp. 201888
Author(s):  
M. M. Tolba ◽  
M. M. Salim ◽  
M. El-Awady

In the present study, we conducted two facile and highly sensitive spectrofluorimetric approaches in order to quantify the vasoprotective agents; troxerutin (TROX) and calcium dobesilate (DOB) in the presence of hydroquinone (HQ) (as a highly toxic impurity and potential degradation product of DOB) in commercial formulations and human plasma. The first approach relies simply on using ethanol as an eco-friendly solvent for the estimation of DOB at 345 nm after being excited at 305 nm. The linearity was carefully investigated between DOB concentration and the relative fluorescence intensity in the range of 0.05–0.8 µg ml −1 . Due to the high method simplicity and sensitivity, applying the first approach to quality control analysis and spiked human plasma samples with mean % recoveries 100.74 ± 3.71 adds another merit. The second approach involved rapid conventional fluorimetric estimation of ethanolic TROX solution in TROX/DOB combined dosage forms at 455/350 nm (emission/excitation) with a linear calibration chart covering the range of 0.1–1.2 µg ml −1 . Moreover, the second approach involved a comprehensive study in a trial to solve the problem of superposition of DOB and HQ graph adopting the first derivative synchronous fluorimetric mechanism in ethanol at Δ λ = 60 nm. Therefore, DOB was measured at 286 and 323 nm, while HQ could be quantitated at 301 nm. The Beer–Lambert Law has complied over the ranges of 0.1–1.0 and 0.02–0.4 µg ml −1 for DOB and HQ, respectively. Guidelines adopted by the International Council of Harmonization (ICH) were used to validate the target approaches. The developed methods are more convenient for routine quality control laboratory instead of the time-consuming and sophisticated reported techniques. Moreover, different aspects of evaluating the greenness of the proposed approaches were conducted to have a complete image of their environmental impact.


2012 ◽  
Vol 2012 ◽  
pp. 1-10 ◽  
Author(s):  
Dinesh S. Patel ◽  
Naveen Sharma ◽  
Mukesh C. Patel ◽  
Bhavin N. Patel ◽  
Pranav S. Shrivastav ◽  
...  

A reliable, rapid, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been proposed for the determination of rizatriptan in human plasma using sumatriptan as internal standard (IS). The analyte and IS were extracted from 300 μL human plasma via liquid-liquid extraction and the chromatography was achieved on Hypurity C18 (50 mm × 4.6 mm, 5 μm) column under isocratic conditions. Detection of rizatriptan and IS was done by tandem mass spectrometry, operating in positive ionization and multiple-reaction monitoring mode. The limit of detection and lower limit of quantitation of the method were 0.04 and 0.20 ng/mL, respectively, with a linear dynamic range of 0.20–60.0 ng/mL. The intrabatch and interbatch precision (% CV) was ≤8.4% while the mean extraction recovery was >78% across quality control levels. Bench top stability, freeze and thaw stability, processed sample stability, and long-term stability in plasma were evaluated at two quality control levels. It was successfully applied to a bioequivalence study of 10 mg rizatriptan orally disintegrating tablet formulation in 40 and 32 healthy Indian male subjects under fasting and fed conditions, respectively. The reproducibility in the measurement of study data was demonstrated by reanalysis of 254 incurred samples.


Author(s):  
SAI PRUDHVI N. ◽  
VENKATESWARLU B. S. ◽  
KUMUDHAVALLI M. V. ◽  
MURUGANANTHAM V.

Objective: The present work aimed to develop a novel, reliable and accurate Liquid Chromatography-Mass Spectrometry/Mass spectrometry (LC-MS/MS) method for the simultaneous quantification of Decitabine and Cedazuridine a combined medication used for the treatment of chronic myelomonocytic leukemia in human plasma. Methods: Talazoparib drug is used as an internal standard in the study. Both the analytes and internal standard were isolated from 100 ml plasma samples by liquid-liquid extraction and then chromatographed on Zorbax SB-CN (4.6 mm×75 mm, 3.5 µm) column with a mobile phase consisting of 0.1 % ammonium formate and methanol in the ratio of 65:45 (v/v) pumped at 0.5 ml/min. The method had a chromatographic total run time of 5 min. Results: The developed method gave a symmetric peak at a retention time of 1.7 min for Decitabine, 2.2 min for Cedazuridine, 3.5 min for Talazoparib and satisfied all the peak properties as per USP guidelines. The mass spectral characterization of separated analytes in the LC method was performed using a mass detector operated at Multiple Reaction Monitoring mode with precursor-to-product ion transitions at m/z of 229 to m/z of 114 as MH+ion for Decitabine, m/z of 269 to m/z of 118 as MH+ion for Cedazuridine. A very sensitive limit of detection of 0.3 ng/ml was observed and showed a calibration curve linear over the concentration range of LLOQ (lower limit of quantification) to 500 ng/ml. The other validation parameters were found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction concentration was acceptable and very high for both the analytes in HQC (high-quality control concentration), MQC (medium quality control concentration) and LLOQ levels. The peak area response ratio of Decitabine and Cedazuridine with the internal standard in freeze-thaw, short term and long term stability studies was found to be acceptable confirms that the method is stable. Conclusion: It can be concluded that the proposed method is specific, accurate, and precise and could be used for the simultaneous estimation of Decitabine and Cedazuridine in human plasma.


Sign in / Sign up

Export Citation Format

Share Document