A composites-based hyperelastic constitutive model for soft tissue with application to the human annulus fibrosus

2006 ◽  
Vol 54 (9) ◽  
pp. 1952-1971 ◽  
Author(s):  
Z.Y. Guo ◽  
X.Q. Peng ◽  
B. Moran
2007 ◽  
Vol 129 (5) ◽  
pp. 632-641 ◽  
Author(s):  
Ferhun C. Caner ◽  
Zaoyang Guo ◽  
Brian Moran ◽  
Zdeněk P. Bažant ◽  
Ignacio Carol

In a recent paper, Peng et al. (2006, “An Anisotropic Hyperelastic Constitutive Model With Fiber-Matrix Interaction for the Human Annulus Fibrosis,” ASME J. Appl. Mech., 73(5), pp. 815–824) developed an anisotropic hyperelastic constitutive model for the human annulus fibrosus in which fiber-matrix interaction plays a crucial role in simulating experimental observations reported in the literature. Later, Guo et al. (2006, “A Composites-Based Hyperelastic Constitutive Model for Soft Tissue With Application to the Human Fibrosis,” J. Mech. Phys. Solids, 54(9), pp. 1952–1971) used fiber reinforced continuum mechanics theory to formulate a model in which the fiber-matrix interaction was simulated using only composite effect. It was shown in these studies that the classical anisotropic hyperelastic constitutive models for soft tissue, which do not account for this shear interaction, cannot accurately simulate the test data on human annulus fibrosus. In this study, we show that the microplane model for soft tissue developed by Caner and Carol (2006, “Microplane Constitutive Model and Computational Framework for Blood Vessel Tissue,” ASME J. Biomech. Eng., 128(3), pp. 419–427) can be adjusted for human annulus fibrosus and the resulting model can accurately simulate the experimental observations without explicit fiber-matrix interaction because, in microplane model, the shear interaction between the individual fibers distributed in the tissue provides the required additional rigidity to explain these experimental facts. The intensity of the shear interaction between the fibers can be adjusted by adjusting the spread in the distribution while keeping the total amount of the fiber constant. A comparison of results obtained from (i) a fiber-matrix parallel coupling model, which does not account for the fiber-matrix interaction, (ii) the same model but enriched with fiber-matrix interaction, and (iii) microplane model for soft tissue adapted to annulus fibrosus with two families of fiber distributions is presented. The conclusions are (i) that varying degrees of fiber-fiber and fiber-matrix shear interaction must be taking place in the human annulus fibrosus, (ii) that this shear interaction is essential to be able to explain the mechanical behavior of human annulus fibrosus, and (iii) that microplane model can be fortified with fiber-matrix interaction in a straightforward manner provided that there are new experimental data on distribution of fibers, which indicate a spread so small that it requires an explicit fiber-matrix interaction to be able to simulate the experimental data.


Author(s):  
Ericka K. Amborn ◽  
Karim H. Muci-Küchler ◽  
Brandon J. Hinz

Studying the high strain rate behavior of soft tissues and soft tissue surrogates is of interest to improve the understanding of injury mechanisms during blast and impact events. Tests such as the split Hopkinson pressure bar have been successfully used to characterize material behavior at high strain rates under simple loading conditions. However, experiments involving more complex stress states are needed for the validation of constitutive models and numerical simulation techniques for fast transient events. In particular, for the case of ballistic injuries, controlled tests that can better reflect the effects induced by a penetrating projectile are of interest. This paper presents an experiment that tries to achieve that goal. The experimental setup involves a cylindrical test sample made of a translucent soft tissue surrogate that has a small pre-made cylindrical channel along its axis. A small caliber projectile is fired through the pre-made channel at representative speeds using an air rifle. High speed video is used in conjunction with specialized software to generate data for model validation. A Lagrangian Finite Element Method (FEM) model was prepared in ABAQUS/Explicit to simulate the experiments. Different hyperelastic constitutive models were explored to represent the behavior of the soft tissue surrogate and the required material properties were obtained from high strain rate test data reported in the open literature. The simulation results corresponding to each constitutive model considered were qualitatively compared against the experimental data for a single projectile speed. The constitutive model that provided the closest match was then used to perform an additional simulation at a different projectile velocity and quantitative comparisons between numerical and experimental results were made. The comparisons showed that the Marlow hyperelastic model available in ABAQUS/Explicit was able to produce a good representation of the soft tissue surrogate behavior observed experimentally at the two projectile speeds considered.


Author(s):  
Mathias Brieu ◽  
Pierre Chantereau ◽  
Jean Gillibert ◽  
Laurent de Landsheere ◽  
Pauline Lecomte ◽  
...  

2005 ◽  
Vol 73 (5) ◽  
pp. 815-824 ◽  
Author(s):  
X. Q. Peng ◽  
Z. Y. Guo ◽  
B. Moran

Based on fiber reinforced continuum mechanics theory, an anisotropic hyperelastic constitutive model for the human annulus fibrosus is developed. A strain energy function representing the anisotropic elastic material behavior of the annulus fibrosus is additively decomposed into three parts nominally representing the energy contributions from the matrix, fiber and fiber-matrix shear interaction, respectively. Taking advantage of the laminated structure of the annulus fibrosus with one family of aligned fibers in each lamella, interlamellar fiber-fiber interaction is eliminated, which greatly simplifies the constitutive model. A simple geometric description for the shearing between the fiber and the matrix is developed and this quantity is used in the representation of the fiber-matrix shear interaction energy. Intralamellar fiber-fiber interaction is also encompassed by this interaction term. Experimental data from the literature are used to obtain the material parameters in the constitutive model and to provide model validation. Determination of the material parameters is greatly facilitated by the partition of the strain energy function into matrix, fiber and fiber-matrix shear interaction terms. A straightforward procedure for computation of the material parameters from simple experimental tests is proposed.


2011 ◽  
Vol 11 (01) ◽  
pp. 163-176
Author(s):  
XIONGQI PENG ◽  
YU WANG ◽  
ZAOYANG GUO ◽  
SHAOQING SHI

This paper validates a constitutive model for human intervertebral disc annulus fibrosus via numerical simulations on a lumber spine motion segment. This anisotropic hyperelastic fiber-reinforced constitutive model was previously developed by the authors. Based on three-dimensional (3D) lumbar spine segments that are constructed from CT scanning images, a detailed and anatomically accurate human lumbar spine finite element (FE) model for L3–L4 motion segment is developed. The FE model includes vertebral bodies, intervertebral disc, and various ligaments. Numerical simulations are carried out by using commercial CAE software package ABAQUS/Standard. The loading cases considered in the numerical analysis are set to be consistent with sets-up of cadaveric specimen testing available in the literature. Numerical results such as load–displacement curves and nucleus pressure are compared with experimental data. Simulation results show good consistency with cadaveric experimental data, and have good biomechanical fidelity. The constitutive model can be used for human intervertebral disc modeling and biomechanical analysis of human spine column.


2006 ◽  
Vol 128 (6) ◽  
pp. 917-924 ◽  
Author(s):  
Irina Ionescu ◽  
James E. Guilkey ◽  
Martin Berzins ◽  
Robert M. Kirby ◽  
Jeffrey A. Weiss

Understanding the factors that control the extent of tissue damage as a result of material failure in soft tissues may provide means to improve diagnosis and treatment of soft tissue injuries. The objective of this research was to develop and test a computational framework for the study of the failure of anisotropic soft tissues subjected to finite deformation. An anisotropic constitutive model incorporating strain-based failure criteria was implemented in an existing computational solid mechanics software based on the material point method (MPM), a quasi-meshless particle method for simulations in computational mechanics. The constitutive model and the strain-based failure formulations were tested using simulations of simple shear and tensile mechanical tests. The model was then applied to investigate a scenario of a penetrating injury: a low-speed projectile was released through a myocardial material slab. Sensitivity studies were performed to establish the necessary grid resolution and time-step size. Results of the simple shear and tensile test simulations demonstrated the correct implementation of the constitutive model and the influence of both fiber family and matrix failure on predictions of overall tissue failure. The slab penetration simulations produced physically realistic wound tracts, exhibiting diameter increase from entrance to exit. Simulations examining the effect of bullet initial velocity showed that the anisotropy influenced the shape and size of the exit wound more at lower velocities. Furthermore, the size and taper of the wound cavity was smaller for the higher bullet velocity. It was concluded that these effects were due to the amount of momentum transfer. The results demonstrate the feasibility of using MPM and the associated failure model for large-scale numerical simulations of soft tissue failure.


2009 ◽  
Vol 37 (6) ◽  
pp. 1117-1130 ◽  
Author(s):  
Huang Tang ◽  
Markus J. Buehler ◽  
Brian Moran

Sign in / Sign up

Export Citation Format

Share Document