Measurements of concentrations and its ratio of radon decay products in rainwater by gamma-ray spectrometry with a low background germanium detector

2005 ◽  
Vol 1276 ◽  
pp. 289-290
Author(s):  
M. Takeyasu ◽  
T. Iida ◽  
T. Tsujimoto ◽  
K. Yamasaki
2019 ◽  
Vol 186 (2-3) ◽  
pp. 280-283
Author(s):  
Miroslav Hýža ◽  
Petr Rulík ◽  
Vojtěch Bednář

Abstract High-volume aerosol samplers combined with laboratory analysis using high-resolution gamma ray spectrometry allow determining artificial radionuclides in the atmosphere at sub μBq/m3 levels. A major drawback of this procedure is a significant delay of the analysis result after any potential radioactive contamination deposition on the aerosol filter. Within the scope of the HAMRAD project, an autonomous device was developed in order to increase the sampling and measuring frequency. This approach yields higher detection limits (minimum detectable activity concentration [MDAC]) due to the deposited activity of radon decay products on the filter. In order to quantify the radon effect, a simple mathematical model was developed to predict MDAC for the particular radionuclide of interest for the given background conditions. It was found that MDAC can vary by a factor of ~2 for typical ‘radon’ conditions (~10 Bq/m3) at SÚRO Prague and by a factor up to 5 for high radon concentration (100 Bq/m3).


2006 ◽  
Vol 88 (1) ◽  
pp. 74-89 ◽  
Author(s):  
Masanori Takeyasu ◽  
Takao Iida ◽  
Tadashi Tsujimoto ◽  
Keizo Yamasaki ◽  
Yoshihiro Ogawa

Author(s):  
H. Ramebäck ◽  
S. Jonsson ◽  
T. Vidmar

AbstractThe efficiency transfer procedure from a geometry where a volume source was placed directly on the endcap of a germanium detector to three different distant geometries was carried out using the EFFTRAN code. One of these distant geometries included absorbers consisting of poly(methyl methacrylate). The efficiency transfer to this geometry therefore had to be realized as a two-stage transfer, since a direct efficiency transfer is not possible using EFFTRAN in such a case. Efficiency transfer to all three distant geometries yielded results which can be considered as fit-for-purpose in e.g. most of the applications of gamma ray spectrometry.


2019 ◽  
Vol 322 (3) ◽  
pp. 1311-1321
Author(s):  
Krzysztof Gorzkiewicz ◽  
Jerzy Wojciech Mietelski ◽  
Renata Kierepko ◽  
Kamil Brudecki

Abstract This paper presents results of the development process of low-background, digital gamma-rays spectrometer equipped with Broad Energy Germanium detector (CANBERRA BE5030), multi-layer passive shield and cosmic veto system that consists of five plastic scintillators (SCIONIX EJ-200). Data acquisition is performed using digitizer CAEN DT5725 with CoMPASS software. Output data analysis is carried out with purposely written and developed code VETO. On the basis of conducted tests, acquisition parameters were set up and tuned as well as time delays between all detectors were established. As a result of the configuration process, the mean background counts reduction of 64% in the whole spectrum and 65% in annihilation peak were achieved. This procedure allowed diminishing detection limits of selected isotopes 37% on average.


2016 ◽  
Vol 44 ◽  
pp. 1660237
Author(s):  
Huda Al-Sulaiti ◽  
Tabassum Nasir ◽  
K. S. Al Mugren ◽  
N. Alkhomashi ◽  
N. Al-Dahan ◽  
...  

The goal of this study was to establish the first baseline measurements for radioactivity concentration of the artificial radionuclide [Formula: see text]Cs in soil samples collected from the Qatarian peninsula. The work focused on the determination of the activity concentrations levels of man-made radiation in 129 soil samples collected across the landscape of the State of Qatar. All the samples were collected before the most recent accident in Japan, “the 2011 Fukushima Dai-ichi nuclear power plant accident”. The activity concentrations have been measured via high-resolution gamma-ray spectrometry using a hyper-pure germanium detector situated in a low-background environment with a copper inner-plated passive lead shield. A radiological map showing the activity concentrations of [Formula: see text]Cs is presented in this work. The concentration was[Formula: see text]found to range from 0.21 to 15.41 Bq/kg. The highest activity concentration of [Formula: see text]Cs was observed in sample no. 26 in North of Qatar. The mean value was found to be around 2.15 ± 0.27 Bq/kg. These values lie within the expected range relative to the countries in the region. It is expected that this contamination is mainly due to the Chernobyl accident on 26 April 1986, but this conclusion cannot be confirmed because of the lack of data before this accident.


2019 ◽  
Vol 98 (8) ◽  
pp. 878-884
Author(s):  
Igor P. Korenkov ◽  
T. N. Lashchenova ◽  
N. K. Shandala ◽  
A. I. Ermakov ◽  
A. B. Mayzik

The article describes the evaluation of the efficiency of using the technology of dry method of decontamination of α-radionuclides from working surfaces of premises for different materials, equipment and building structures. Materials and methods. Instruments for measuring of ambient dose equivalent rate (ADER) with a lower limit of 0.03 μSv/h. Specific activity of α-radionuclides in the samples was determined by radiometric, radiochemical and spectrometric methods using standard methods in the accredited laboratory. The measurements in situ were also carried out using the ISOCS «CANBERRA» mobile gamma-ray spectrometry system with high purity germanium detector and a collimator. Technological equipment included industrial vacuum cleaner with nozzles; high-pressure device; packing sets for RAW collection; HEPA filters; personal protective equipment. Results. Maps of spatial distribution of surface α-contamination in the building was constructed. We performed cluster analysis of data for zoning of contaminated surfaces. The decontamination factor for porous (brick, concrete), smooth (wood, brown tiles, laminate) and sticky (bitumen, mastic) surfaces was determined. Conclusion. The cluster analysis made it possible to identify 4 levels of surface α- and β- contamination, particles/cm2 ∙ min: zone I - for α- above 50, for β- above 10,000; zone II - for α- 5-50, for β- 2,000-10,000; zone III - for α- no more than 5, for β- 2000; zone IV - corresponds to the background values of the workspace surfaces. The dry decontamination method revealed a high content of fine dust aerosol fraction deposited in the lungs. To increase the efficiency of dust suppression, water aerosol with droplet size of 100 - 400 microns and quartz sand with particle size of 100-200 microns were sprayed at the rate of 200-400 g per 1 m2. The decontamination coefficient depends on the coating material and the level of surface contamination: concrete - 91 to 97.8%; brick - 85-86%, wood - 38.8-53%; brownstone tiles - up to 29%; mastic - 22-28%; bitumen - 15.9-20%. To protect the personnel, radiation-hygienic rationing of PM10 and PM2,5 content is necessary.


Author(s):  
Huilan Liu ◽  
Yushou Song ◽  
Zhaoyang Xie ◽  
Baodong Sun

A low-background gamma spectrometer consists of a high-performance gamma detector and a low-background chamber. It is widely used to monitor the radiation level of the environment and to identify the species of the radiological source. It is especially important for the analysis of the nuclear accident. Usually a high purity Germanium detector (HPGe) is used as a gamma ray detector. In order to enhance the detecting accuracy and sensitivity, it is essential to improve the performance of the gamma detector. In recent years, a clover detector composed of four coaxial HPGe crystals appear and is widely utilized in nuclear physics experimental research. Because of the larger dimensions and segmented structure, it displays outstanding characteristics different from traditional HPGe detectors. With a clover detector as the main detector and the HPLBS1 chamber of ORTEC as the lead chamber, the low-background gamma spectrometer is simulated by the Monte Carlo toolkit GEANT4, where the interaction processes of gamma ray provided by the GEANT4 physics list is used. The detecting performance of the low-background gamma spectrometer such as detecting efficiency and peak-total ratio are given. The results indicate that low-background gamma spectrometer with a clover as the main detector has better characteristic than that with HPGe as a main detector traditionally.


2017 ◽  
Vol 126 ◽  
pp. 240-242 ◽  
Author(s):  
L.R. Greenwood ◽  
M.G. Cantaloub ◽  
J.L. Burnett ◽  
A.W. Myers ◽  
C.T. Overman ◽  
...  

Author(s):  
Mihaela Roxana Ene ◽  
◽  
Gheorghe Bulubasa ◽  
Alina Florentina Miu ◽  
◽  
...  

The aim of this study was to determine naturally occurring radionuclide 40K in surface water samples from Olt River, Romania. A monitoring study during 7 years (2012-2018) was accomplished. A number of 728 surface water samples were collected and analysed. Several hundred pollution sources were identified for the Olt River basin in Romania. This study is of particular importance since it is the first effort to evaluate the activity concentrations of 40K in surface water from Romania for such a long period. For this reason, two sampling points along the Olt River were chosen, the first one upstream of the discharge point of the magistrate channel "Deversor Olt" (reference location) and respectively the second sampling point downstream of the liquid effluents discharges point (indicator location). The radioactivity concentration of 40K was determined from the 1460.8 keV photopeak. The method used was high resolution gamma ray spectrometry performed with a hyperpure germanium detector. An activity concentration for 40K, no more than 2.14 ± 0.32 Bq l -1 , is observed, but the values recorded for the background location had a slight, but not significant difference compared with the values recorded in the second sampling point.


Sign in / Sign up

Export Citation Format

Share Document