Efficiency of steel fibers in shear resistance of reinforced concrete beams without stirrups at different moment-to-shear ratios

2019 ◽  
Vol 188 ◽  
pp. 249-260 ◽  
Author(s):  
Sahith Gali ◽  
Kolluru V.L. Subramaniam

Over the past few decades, a significant growth was observed on utilization of steel fibers in Reinforced Concrete (R.C) members. Past research studies on hybrid concrete endorsed optimum utilization of steel fibers (1.5% by volume) as it effectively contributed to improve flexural properties of reinforced concrete members such as R.C beams and slabs .But the contribution of fibers against shear resistance mechanism of R.C beams are not identified well in the previous research. In this context an experimental program was conducted to find Shear contribution and associated Parameters of fibers in the Steel Fiber Reinforced Concrete (SFRC) beams. A series of test programmes are conducted on three full scale reinforced concrete beams (NSF: No steel fibers, BSF1: Steel fibers in shear span, BSF2: Steel fibers in full span) with different configuration of shear reinforcement by using varied range of SFRC in the tested beam. The test results evaluated on the basis of strength and durability aspects at service loads and limit of failure conditions. The results concluded that the presence of steel fibers in reinforced concrete beam significantly contributed to induce shear resistance mechanism and ductile property of R.C beam. This improvement observed in BSF2, when the SFRC constituted in shear span region and the rest of R.C beam arranged with minimum conventional stirrups as shear reinforcement. Further the steel fibers possess good compatibility with concrete and steel reinforcement ,which enhance mechanical and serviceability conditions of R.C beam such as shear strength, ductility, stiffness with respect to strength and deflection, crack width during serviceability conditions of the beam.


2020 ◽  
Vol 38 (5A) ◽  
pp. 669-680
Author(s):  
Ghazwan K. Mohammed ◽  
Kaiss F. Sarsam ◽  
Ikbal N. Gorgis

The study deals with the effect of using Slurry infiltrated fiber concrete (SIFCON) with the reinforced concrete beams to explore its enhancement to the flexural capacity. The experimental work consists of the casting of six beams, two beams were fully cast by conventional concrete (CC) and SIFCON, as references. While the remaining was made by contributing a layer of SIFCON diverse in-depth and position, towards complete the overall depths of the built-up beam with conventional concrete CC. Also, an investigation was done through the control specimens testing about the mechanical properties of SIFCON. The results showed a stiffer behavior with a significant increase in load-carrying capacity when SIFCON used in tension zones. Otherwise high ductility and energy dissipation appeared when SIFCON placed in compression zones with a slight increment in ultimate load. The high volumetric ratio of steel fibers enabled SIFCON to magnificent tensile properties.


Author(s):  
Aaron Kadima Lukanu Lwa Nzambi ◽  
Dênio Ramam Carvalho de Oliveira ◽  
Marcus Vinicius dos Santos Monteiro ◽  
Luiz Felipe Albuquerque da Silva

Abstract Some normative recommendations are conservative in relation to the shear strength of reinforced concrete beams, not directly considering the longitudinal reinforcement rate. An experimental program containing 8 beams of (100 x 250) mm2 and a length of 1,200 mm was carried out. The concrete compression strength was 20 MPa with and without 1.00% of steel fiber addition, without stirrups and varying the longitudinal reinforcement ratio. Comparisons between experimental failure loads and main design codes estimates were assessed. The results showed that the increase of the longitudinal reinforcement ratio from 0.87% to 2.14% in beams without steel fiber led to an improvement of 59% in shear strength caused by the dowel effect, while the corresponding improvement was of only 22% in fibered concrete beams. A maximum gain of 109% in shear strength was observed with the addition of 1% of steel fibers comparing beams with the same longitudinal reinforcement ratio (1.2%). A significant amount of shear strength was provided by the inclusion of the steel fibers and allowed controlling the propagation of cracks by the effect of stress transfer bridges, transforming the brittle shear mechanism into a ductile flexural one. From this, it is clear the shear benefit of the steel fiber addition when associated to the longitudinal reinforcement and optimal values for this relationship would improve results.


Author(s):  
Natalia Sharma

Abstract: Reinforced concrete structures are frequently in need of repair and strengthening as a result of numerous environmental causes, ageing, or material damage under intense stress conditions, as well as mistakes made during the construction process. RC structures are repaired using a variety of approaches nowadays. The usage of FRC is one of the retrofitting strategies. Steel fiber reinforced concrete (SFRC) was used in this investigation because it contains randomly dispersed short discrete steel fibers that operate as internal reinforcement to improve the cementitious composite's characteristics (concrete). The main rationale for integrating small discrete fibers into a cement matrix is to reduce the amount of cement used. The principal reason for incorporating short discrete fibers into a cement matrix is to reduce cracking in the elastic range, increase the tensile strength and deformation capacity and increase the toughness of the resultant composite. These properties of SFRC primarily depend upon length and volume of Steel fibers used in the concrete mixture. In India, the steel fiber reinforced concrete (SFRC) has seen limited applications in several structures due to the lack of awareness, design guidelines and construction specifications. Therefore, there is a need to develop information on the role of steel fibers in the concrete mixture. The experimental work reported in this study includes the mechanical properties of concrete at different volume fractions of steel fibers. These mechanical properties include compressive strength, split tensile strength and flexural strength and to study the effect of volume fraction and aspect ratio of steel fibers on these mechanical properties. However, main aim of the study was significance of reinforced concrete beams strengthened with fiber reinforced concrete layer and to investigate how these beams deflect under strain. The objective of the investigation was finding that applying FRC to strengthen beams enhanced structural performance in terms of ultimate load carrying capacity, fracture pattern deflection, and mode of failure or not.


2018 ◽  
Vol 250 ◽  
pp. 03003
Author(s):  
Noor Suhaida Galip ◽  
Roslli Noor Mohamed ◽  
Ramli Abdullah

The bent-up bars have not been used as shear reinforcement in beams since the past 40 years or so. In all cases of design and construction nowadays, shear forces are resisted by vertical links only. Some complications in installing the multiple set of bent-up bars, the less opportunity to have sufficient number of bent-up bars due to small number of flexural reinforcement provided at the mid-span of the beams and also the large anchorage required for the horizontal portion of the bars beyond the upper end of the bend could be the reasons behind this. This paper presents the results of tests on five rectangular reinforced concrete beams in which the effectiveness of welded inclined bars (WIB) as shear reinforcement was studied. Two of the beams were controlled specimens, with no shear reinforcement in one, and full design vertical links in another. The other three beams were provided with three different quantities of WIB, measured in terms of area to distance ratio, Asw / S as shear reinforcement in the shear spans. All beams were tested to failure under two point loads with a shear span to effective depth ratio of 2.34, which would ensure that the failure was due to shear unless their shear capacities were larger than the flexural capacity. The performances of the beams were measured in terms of deflection, crack formation, strains in WIB and on the concrete surfaces in the shear region, ultimate loads and failure modes. The results show that WIB alone is capable of carrying the whole shear forces in the beam, and larger shear capacities are achieved with a larger quantity of WIB, and a higher grade of the bars used. The beam with WIB requires 22% less in the quantity of Asw / S compared to that with vertical links to achieve the same shear resistance. These suggest that WIB can be used as an effective system of shear reinforcement in beams.


2019 ◽  
Vol 10 (4) ◽  
pp. 457-469 ◽  
Author(s):  
Avraham N Dancygier ◽  
Yuri S Karinski

This article presents a study of cracking localization in normal and high strength concrete beams that include steel fibers and the influence of this localization on their structural ductility. It is shown that for a given fiber type and content, as the reinforcement ratio ρ decreases, the cracking localization level increases. The effect of ρ on the level of cracking localization is more pronounced for low amounts of conventional reinforcement. This range of conventional reinforcement ratio is typical of slabs and especially for the commonly thicker protective slabs. Examination of the effect of the reinforcement ratio on the flexural ductility shows that there exists a transition point below which the ductility ratio decreases with  ρ. This transition point is well above the minimum reinforcement ratio, which is required in design codes for plain reinforced concrete elements. Empirical analysis of the relation between cracking localization and ductility ratio shows that up to the same transition point, as cracking localization increases, the flexural ductility decreases. Findings of this study show that the positive effect of adding fibers on enhancing the impact resistance of slabs and beams is conflicted by their negative influence on reducing the structural ductility for low reinforcement ratios, which are typical of protective slabs.


2018 ◽  
Vol 11 (5) ◽  
pp. 997-1024
Author(s):  
T. E. T. BUTTIGNOL ◽  
J. F. FERNANDES ◽  
T. N. BITTENCOURT ◽  
J. L. A. O. SOUSA

Abstract This paper carries out a design analysis of reinforced concrete beams with steel fibers following the fib Model Code 2010 (MC 2010) procedures. The values obtained from the design calculations are compared with the experimental results of reinforced concrete beams with 20kg/m3 and 60 kg/m3 of steel fibers submitted to four-point bending tests. In the first part, the procedures for the classification and characterization of the material are explained. The experimental results of three-point bending tests performed on notched steel fiber reinforced concrete (FRC) beams following EN 14651 procedures are described. Moreover, the characterization of the FRC beams according to MC 2010, are carried out. In the second part, the flexural design of reinforced concrete beams with steel fibers, according to MC 2010, is carried out. A sectional analysis is performed in order to obtain the moment-curvature and the force-vertical displacement curves. The theoretical values are compared with the experimental results. Besides, a linear statistic analysis by means of the Rule of Mixture is carried out in order to analyze the variation of the flexural capacity of the reinforced beams with different amounts of steel fibers. The results demonstrated that the design rules described in the MC 2010 are on the safe side. The flexural resistance of concretes with different amounts of fiber incorporation can be determined by the Rule of Mixture, which has shown a high correlation factor (R2) with the experimental values.


Sign in / Sign up

Export Citation Format

Share Document