Experimental investigation on shear capacity of reinforced concrete slabs with plain bars and slabs on elastomeric bearings

2015 ◽  
Vol 103 ◽  
pp. 1-14 ◽  
Author(s):  
Eva O.L. Lantsoght ◽  
Cor van der Veen ◽  
Joost Walraven ◽  
Ane de Boer
Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4622
Author(s):  
Kevin Paolo V. Robles ◽  
Jurng-Jae Yee ◽  
Seong-Hoon Kee

The main objectives of this study are to evaluate the effect of geometrical constraints of plain concrete and reinforced concrete slabs on the Wenner four-point concrete electrical resistivity (ER) test through numerical and experimental investigation and to propose measurement recommendations for laboratory and field specimens. First, a series of numerical simulations was performed using a 3D finite element model to investigate the effects of geometrical constraints (the dimension of concrete slabs, the electrode spacing and configuration, and the distance of the electrode to the edges of concrete slabs) on ER measurements of concrete. Next, a reinforced concrete slab specimen (1500 mm (width) by 1500 mm (length) by 300 mm (thickness)) was used for experimental investigation and validation of the numerical simulation results. Based on the analytical and experimental results, it is concluded that measured ER values of regularly shaped concrete elements are strongly dependent on the distance-to-spacing ratio of ER probes (i.e., distance of the electrode in ER probes to the edges and/or the bottom of the concrete slabs normalized by the electrode spacing). For the plain concrete, it is inferred that the thickness of the concrete member should be at least three times the electrode spacing. In addition, the distance should be more than twice the electrode spacing to make the edge effect almost negligible. It is observed that the findings from the plain concrete are also valid for the reinforced concrete. However, for the reinforced concrete, the ER values are also affected by the presence of reinforcing steel and saturation of concrete, which could cause disruptions in ER measurements


2013 ◽  
Vol 40 (11) ◽  
pp. 1060-1067 ◽  
Author(s):  
Hizia Bellakehal ◽  
Ali Zaidi ◽  
Radhouane Masmoudi ◽  
Mohamed Bouhicha

Flexural behaviour of reinforced-concrete slabs has been widely investigated to characterize properties and behaviour of fibre-reinforced polymer (FRP) materials as reinforcement for concrete structures. However, the short- and long-term thermal effects on FRP bars owing to the significant difference between the bars’ coefficients of thermal expansion in the transverse and longitudinal directions are still to be evaluated and may affect the bond properties and the concrete cover thickness after multiple exposures to freeze–thaw cycles. This paper presents the thermostructural behaviour of one-way concrete slabs reinforced with glass FRP (GFRP) that have previously been subjected to mechanical loads of 20% and 30% of the ultimate flexural capacity of reinforced-concrete slabs, simultaneously with short freeze–thaw cycles. Series tests were conducted on FRP-reinforced concrete slabs 500 mm wide, 195–215 mm thick, and 2500 mm long. The thermal cycles were varied from −30 to 60 °C. Four-point bending tests were conducted up to failure of the slabs. The results show that the thermomechanical load applied before bending tests increases the performance of reinforced-concrete slabs, particularly the concrete shear capacity. The deflection predicted from CSA code and ACI guidelines are very close to those obtained from experimental tests; however, the CSA code overestimates the deflection at the service load. The applied thermal cycles have no big influence on the behaviour before shear failure of concrete slabs reinforced with GFRP bars.


2017 ◽  
Vol 5 (2) ◽  
pp. 1-7
Author(s):  
Ilker Kara ◽  
Besian Sinani

An innovative solution to the corrosion problem is the use of fiber-reinforced polymer (FRP) as an alternative reinforcing material in concrete structures. In addition to the non corrodible nature of FRP materials, they also have a high strength-to-weight ratio that makes them attractive as reinforcement for concrete structures. Extensive research programs have been carried out to investigate the flexural behavior of concrete members reinforced with FRP reinforcement. On the other hand, the shear behavior of concrete members, especially punching shear of two-way slabs, reinforced with FRP bars has not yet been fully explored. The existing provisions for punching of slabs in most international design standards for reinforced concrete are based on tests of steel reinforced slabs. The elastic stiffness and bonding characteristics of FRP reinforcement are sufficiently different from those of steel to affect punching strength. In the present study, the equations of existing design standards for shear capacity of FRP reinforced concrete beams have been evaluated using the large database collected. The experimental punching shear strengths were compared with the available theoretical predictions, including the CSA S806 (CSA 2012), ACI-440.1R-15 (ACI 2015), BS 8110 (BSI 1997), JSCE (1997) a number of models proposed by some researchers in the literature. The existing design methods for FRP reinforced concrete slabs give conservative predictions for the specimens in the database. This paper also presents a simple yet improved model to calculate the punching shear capacity of FRPreinforced concrete slabs. The proposed model provides the accurate results in calculating the punching shear strengths of FRP-reinforced concrete slender slabs.


1996 ◽  
Vol 23 (2) ◽  
pp. 502-510 ◽  
Author(s):  
N. J. Gardner

The validity of the CSA A23.3-94 code provisions for punching shear were compared with the punching shear results of 142 reinforced concrete flat slabs, 16 prestressed concrete flat slabs with unbonded tendons, and 17 flat slabs with unbonded prestressed and supplementary bonded reinforcement. The code prediction equations are not capable of direct verification against experimental results without using a correction factor. Using a justifiable correction factor, the CSA A23.3-94 provisions are appropriately conservative for reinforced concrete slabs but the scatter is large. However, it was concluded that the CSA A23.3-94 provisions are not conservative for prestressed concrete flat slabs. An equation is proposed to calculate the punching shear capacity of reinforced concrete and prestressed concrete slabs, which has a smaller coefficient of variation than the punching shear provisions of CSA A23.3-94, for symmetrically loaded interior columns. The critical section of the proposed method is the perimeter of the column, which is easier to justify than an arbitrary critical perimeter half the effective depth of slab from the column. Key words: reinforced concrete, prestressed concrete, flab slabs, punching shear.


Sign in / Sign up

Export Citation Format

Share Document