Nonlinear behavior and ultimate load bearing capacity of reinforced concrete natural draught cooling tower shell

2006 ◽  
Vol 28 (3) ◽  
pp. 399-410 ◽  
Author(s):  
Hyuk Chun Noh
2010 ◽  
Vol 163-167 ◽  
pp. 2240-2246 ◽  
Author(s):  
Jun Hua Li ◽  
Yue Feng Tang ◽  
Ming Zhe Liu

This paper provided three test data pertaining to the mechanical properties of steel reinforced concrete (SRC) eccentric columns after exposure to fire and one comparative test data pertaining to the mechanical properties of steel reinforced concrete columns at room temperature. The influence of eccentricity on failure mode, distortion performance and ultimate load bearing capacity are mainly studied. Test results show that the failure modes of steel reinforced concrete eccentric columns after exposure to fire are similar to that at room temperature. Strain along the section height at mid-span section of eccentric columns before loaded to 90% ultimate load bearing capacity is linearly distributed and well agree with the plane section supposition. After exposure to fire, the flexural rigidity and load bearing capacity of specimens are all declined compared with that at normal temperature. In various loading stages from the initial loading to 80% ultimate strength, the ratio of flexural rigidity of SRC eccentric columns after exposure to fire and at normal temperature is ranged from 0.30 to 0.59. With the same concrete strength and heating condition, the ultimate strength of specimens decreases with the increasing of eccentricity. The ultimate bearing capacity of all specimens at normal room temperature is calculated on the method proposed by Chinese regulation JGJ 138-2001. The compared results of experimental values and calculating values show that the residual load bearing capacity of SRC eccentric columns after exposure to fire is about 69% to 81% of that at room temperature.


2021 ◽  
Vol 60 (1) ◽  
pp. 64-79
Author(s):  
Junqing Hong ◽  
Shaofeng Zhang ◽  
Hai Fang ◽  
Xunqian Xu ◽  
Honglei Xie ◽  
...  

Abstract The performance of textile reinforced concrete composite panels (TRCCPs) under the action of pseudo-static load up to collapse was evaluated. The test of TRCCPs under axial and transverse loading was conducted, and the results were compared with those for steel wire mesh reinforced-concrete composite panels (SMRCCPs). Ceram-site concrete was utilized as the panel matrix owing to its lightweight and insulation characteristics. The ultimate load bearing capacity, load-deformation and load-strain relationships, and failure modes were discussed and investigated in comparison with the findings of non-linear finite-element-model (FEM) analysis and the analytic method on the basis of the reinforced concrete (RC) theory. The analysis results indicate that TRCCP is suitable for use as a potential structural member for a wall or slab system of buildings, and the typical RC theory can be applied to predict the ultimate load bearing capacity if modified suitably.


2011 ◽  
Vol 243-249 ◽  
pp. 5122-5127
Author(s):  
Jia Feng Xu ◽  
Ming Zhe Liu ◽  
Yue Feng Tang

This paper provided three test data pertaining to the mechanical properties of reinforced concrete columns after exposure to ISO834 standard fire and three comparative test data pertaining to the mechanical properties of reinforced concrete columns at room temperature, mainly concerning the influence of fire on failure mode, distortion performance and ultimate load bearing capacity of reinforced concrete columns under axial and eccentric compression. Test results show that the failure mode of reinforced concrete columns after exposure to fire is basically same with that at room temperature. With the same concrete strength and heating condition, the bearing capacity of specimens reduces as the eccentricity increases. Strain along the section height of eccentric columns after fire basically agree with the plane section supposition while the flexural rigidity and ultimate load bearing capacity decreases obviously. The residual load bearing capacity of reinforced concrete columns after exposure to fire is only about 25% to 37% of that at room temperature.


2004 ◽  
Vol 88 (6) ◽  
pp. 461-466
Author(s):  
Hua Zhao ◽  
Xudong Shao ◽  
Guangdong Liu ◽  
Mingxian Cheng ◽  
Ping Zhu

2021 ◽  
Vol 60 (1) ◽  
pp. 503-518
Author(s):  
Juan Han ◽  
Lu Zhu ◽  
Hai Fang ◽  
Jian Wang ◽  
Peng Wu

Abstract This article proposed an innovative composite sandwich structure reinforced with trapezoidal latticed webs with angles of 45°, 60° and 75°. Four specimens were conducted according to quasi-static compression methods to investigate the compressive behavior of the novel composite structures. The experimental results indicated that the specimen with 45° trapezoidal latticed webs showed the most excellent energy absorption ability, which was about 2.5 times of the structures with vertical latticed webs. Compared to the traditional composite sandwich structure, the elastic displacement and ultimate load-bearing capacity of the specimen with 45° trapezoidal latticed webs were increased by 624.1 and 439.8%, respectively. Numerical analysis of the composite sandwich structures was carried out by using a nonlinear explicit finite element (FE) software ANSYS/LS-DYNA. The influence of the thickness of face sheets, lattice webs and foam density on the elastic ultimate load-bearing capacity, the elastic displacement and initial stiffness was analyzed. This innovative composite bumper device for bridge pier protection against ship collision was simulated to verify its performance. The results showed that the peak impact force of the composite anti-collision device with 45° trapezoidal latticed webs would be reduced by 17.3%, and the time duration will be prolonged by about 31.1%.


Sign in / Sign up

Export Citation Format

Share Document