scholarly journals Comparison of Abdominal Aortic Aneurysm Sac and Neck Wall Motion with 4D Ultrasound Imaging

2020 ◽  
Vol 60 (4) ◽  
pp. 539-547
Author(s):  
Wojciech Derwich ◽  
Andreas Wittek ◽  
Achim Hegner ◽  
Claus-Peter Fritzen ◽  
Christopher Blase ◽  
...  
1997 ◽  
Vol 4 (3) ◽  
pp. 272-278 ◽  
Author(s):  
Torgrim Lie ◽  
Jan Lundbom ◽  
Staal Hatlinghus ◽  
Aage Grønningsaeter ◽  
Steinar Ommedal ◽  
...  

Purpose: To evaluate different ultrasound modalities during implantation and follow-up of endovascular grafts for abdominal aortic aneurysm (AAA) exclusion. Methods: Between February 1995 and May 1996, 18 patients (14 men; aged 49 to 80 years, mean 67) were treated with endovascular intervention for infrarenal AAA. Seventeen patients received Mialhe Stentor bifurcated grafts, while one patient was treated with a straight graft for pseudoaneurysm. During and after the implantation, 3.25- and 5-MHz annular array ultrasound probes were used for transabdominal visualization of the endograft. Intravascular ultrasound was applied in combination with angiography for postoperative control. Results: Intraprocedurally, transabdominal two-dimensional (2D) ultrasound successfully monitored guidewire passage from the groin into the main part of the bifurcated endograft for implantation of the second limb. All implantation procedures were technically successful, but four endoleaks were identified intraprocedurally by 2D ultrasound and angiography. One healed spontaneously, two were treated with endovascular techniques at 1 and 4 months, and the last leak was scheduled for repair when the patient died of probable myocardial infarction at 2 months. During follow-up, 2D ultrasound successfully visualized all the endografts; no endoleaks were found in up to 18 months of surveillance. Conclusions: Transabdominal ultrasound imaging could be valuable in bifurcated endograft deployment both for guiding guidewire insertion and for controlling wire position before the second graft limb is connected to the main graft. Provided that satisfactory visualization of the entire endograft can be obtained, ultrasound examination may possibly replace arteriography and computed tomographic scanning as a follow-up investigation.


BJS Open ◽  
2021 ◽  
Vol 5 (1) ◽  
Author(s):  
S M Tomee ◽  
C A Meijer ◽  
D A Kies ◽  
S le Cessie ◽  
M N J M Wasser ◽  
...  

Abstract Background The management of abdominal aortic aneurysm (AAA) is fully dictated by AAA size, but there are no uniform measurement guidelines, and systematic differences exist between ultrasound- and CT-based size estimation. The aim of this study was to devise a uniform ultrasound acquisition and measurement protocol, and to test whether harmonization of ultrasound and CT readings is feasible. Methods A literature review was undertaken to evaluate evidence for ultrasound-based measurement of AAA. A protocol for measuring AAA was then developed, and intraobserver and interobserver reproducibility was tested. Finally, agreement between ultrasound readings and CT-based AAA diameters was evaluated. This was an observational study of patients with a small AAA who participated in two pharmaceutical intervention trials. Results Based on a literature review, an ultrasound acquisition and reading protocol was devised. Evaluation of the protocol showed an intraobserver repeatability of 1.6 mm (2s.d.) and an interobserver intraclass correlation coefficient (ICC) of 0.97. Comparison of protocolled ultrasound readings and local CT readings indicated a good correlation (r = 0.81), but a systematic +4.1-mm difference for CT. Harmonized size readings for ultrasound imaging and CT increased the correlation (r = 0.91) and reduced the systematic difference to +1.8 mm by CT. Interobserver reproducibility of protocolized CT measurements showed an ICC of 0.94 for the inner-to-inner method and 0.96 for the outer-to-outer method. Conclusion The absence of harmonized size acquisition and reading guidelines results in overtreatment and undertreatment of patients with AAA. This can be avoided by the implementation of standardized ultrasound acquisition and a harmonized reading protocol for ultrasound- and CT-based readings.


Sign in / Sign up

Export Citation Format

Share Document