scholarly journals Prognostic Value of Left Ventricular Deformation Parameters in Patients with Severe Aortic Stenosis: A Pilot Study of the Usefulness of Strain Echocardiography

2017 ◽  
Vol 30 (8) ◽  
pp. 727-735.e1 ◽  
Author(s):  
Lars Gunnar Klaeboe ◽  
Trine F. Haland ◽  
Ida S. Leren ◽  
Rachel M.A. ter Bekke ◽  
Pål H. Brekke ◽  
...  
2020 ◽  
Vol 21 (11) ◽  
pp. 1248-1258 ◽  
Author(s):  
E Mara Vollema ◽  
Mohammed R Amanullah ◽  
Edgard A Prihadi ◽  
Arnold C T Ng ◽  
Pieter van der Bijl ◽  
...  

Abstract Aims Cardiac damage in severe aortic stenosis (AS) can be classified according to a recently proposed staging classification. The present study investigated the incremental prognostic value of left ventricular (LV) global longitudinal strain (GLS) over stages of cardiac damage in patients with severe AS. Methods and results From an ongoing registry, a total of 616 severe symptomatic AS patients with available LV GLS by speckle tracking echocardiography were selected and retrospectively analysed. Patients were categorized according to cardiac damage on echocardiography: Stage 0 (no damage), Stage 1 (LV damage), Stage 2 (mitral valve or left atrial damage), Stage 3 (tricuspid valve or pulmonary artery vasculature damage), or Stage 4 (right ventricular damage). LV GLS was divided by quintiles and assigned to the different stages. The endpoint was all-cause mortality. Over a median follow-up of 44 [24–89] months, 234 (38%) patients died. LV GLS was associated with all-cause mortality independent of stage of cardiac damage. After incorporation of LV GLS by quintiles into the staging classification, Stages 2–4 were independently associated with outcome. LV GLS showed incremental prognostic value over clinical characteristics and stages of cardiac damage. Conclusion In this large single-centre cohort of severe AS patients, incorporation of LV GLS by quintiles in a novel proposed staging classification resulted in refinement of risk stratification by identifying patients with more advanced cardiac damage. LV GLS was shown to provide incremental prognostic value over the originally proposed staging classification.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
C Chin ◽  
T T Le ◽  
G Singh ◽  
J Yip ◽  
S C Chai ◽  
...  

Abstract Background Left ventricular global longitudinal strain (LV-GLS) by speckle tracking echocardiography (STE) reflects intrinsic myocardial function, influenced by interstitial abnormalities. Cardiovascular magnetic resonance (CMR) detects myocardial fibrosis non-invasively, but it is limited for widespread use. We aim to establish LV-GLS as a marker of replacement myocardial fibrosis on CMR and validate the prognostic value of LV-GLS thresholds associated with fibrosis. Methods LV-GLS thresholds of replacement fibrosis were established in the derivation cohort: 151 patients (57±10 years; 58% males) with hypertension who underwent STE to measure LV-GLS and CMR for replacement myocardial fibrosis. Prognostic value of the thresholds was validated in a separate outcome cohort: 261 patients with moderate-severe aortic stenosis (AS; 71±12 years; 58% males; NYHA functional class I-II) and preserved LVEF ≥50%. Primary outcome was a composite of cardiovascular mortality, heart failure hospitalization, myocardial infarction and cerebrovascular events. Results In the derivation cohort, LV-GLS demonstrated good discrimination (c-statistics 0.74; 95% confidence interval: 0.66–0.83; P<0.001) and calibration (Hosmer-Lemeshow X2=6.37; P=0.605) for replacement fibrosis. In the outcome cohort, 52 events occurred over 16 [3.1, 42.0] months of follow-up. Patients with LV-GLS >−15.0% (corresponding to 95% specificity to rule-in myocardial fibrosis) had the worst outcomes compared to patients with LV-GLS <−21.0% (corresponding to 95% sensitivity to rule-out myocardial fibrosis) and those between −21.0 and −15.0% (log-rank P<0.001; Figure 1). Furthermore, LV-GLS offered independent prognostic value over clinical variables, AS severity, echocardiographic LVEF and E/e' (hazard ratio 1.18; 95% confidence interval: 1.07 to 1.30; P=0.001). Conclusions LV-GLS thresholds associated with replacement myocardial fibrosis is a novel approach to risk-stratify patients with AS and preserved LVEF (Figure 2). FUNDunding Acknowledgement Type of funding sources: Public grant(s) – National budget only. Main funding source(s): National Medical Research Council Figure 1 Figure 2


Cardiology ◽  
2021 ◽  
pp. 1-11
Author(s):  
Rubén Taboada-Martín ◽  
José María Arribas-Leal ◽  
María Asunción Esteve-Pastor ◽  
José Abellán Alemán ◽  
Francisco Marín ◽  
...  

<b><i>Background:</i></b> The use of rapid deployment and sutureless aortic prostheses is increasing. Previous reports have shown promising results on haemodynamic performance and mortality rates. However, the impact of these bioprostheses on left ventricular mass (LVM) regression remains unknown. We decided to study the changes in remodelling and LVM regression in isolated severe aortic stenosis treated with conventional or Perceval® or Intuity® valves. <b><i>Method and Results:</i></b> From January 2011 to January 2016, 324 bioprostheses were implanted in our centre. The collected characteristics were divided into 3 groups: conventional valves, Perceval®, and Intuity®, and they were analysed after 12 months. There were 183 conventional valves (56%), 72 Perceval® (22%), and 69 Intuity® (21.2%). The statistical analysis showed significant differences in transprosthetic postoperative peak gradient (23 [18–29] mm Hg vs. 21 [16–29] mm Hg and 18 [14–24] mm Hg, <i>p</i> &#x3c; 0.001), ventricular mass electrical criteria regression (Sokolow and Cornell products), and 1-year survival (90 vs. 93% and 97%, log rank <i>p</i> value = 0.04) in conventional, Perceval®, and Intuity® groups. <b><i>Conclusions:</i></b> We observed differences in haemodynamic, electrocardiographic, and echocardiographic parameters related to the different types of prosthesis. Patients with the Intuity® prosthesis had the highest reduction in peak aortic gradient and the higher ventricular mass regression. Besides, patients with the Intuity® prosthesis had less risk of mortality during follow-up than the other two groups. Further studies are needed to confirm these findings.


2021 ◽  
Vol 10 (13) ◽  
pp. 2864
Author(s):  
Aleksandra Gamrat ◽  
Katarzyna Trojanowicz ◽  
Michał A. Surdacki ◽  
Aleksandra Budkiewicz ◽  
Adrianna Wąsińska ◽  
...  

Traditional electrocardiographic (ECG) criteria for left ventricular hypertrophy (LVH), introduced in the pre-echocardiographic era of diagnosis, have a relatively low sensitivity (usually not exceeding 25–40%) in detecting LVH. A novel Peguero-Lo Presti ECG-LVH criterion was recently shown to exhibit a higher sensitivity than the traditional ECG-LVH criteria in hypertension. Our aim was to test the diagnostic ability of the novel Peguero-Lo Presti ECG-LVH criterion in severe aortic stenosis. We retrospectively analyzed 12-lead ECG tracings and echocardiographic records from the index hospitalization of 50 patients with isolated severe aortic stenosis (mean age: 77 ± 10 years; 30 women and 20 men). Exclusion criteria included QRS > 120 ms, bundle branch blocks or left anterior fascicular block, a history of myocardial infarction, more than mild aortic or mitral regurgitation, and significant LV dysfunction by echocardiography. We compared the agreement of the novel Peguero-Lo Presti criterion and traditional ECG-LVH criteria with echocardiographic LVH (LV mass index > 95 g/m2 in women and >115 g/m2 in men). Echocardiographic LVH was found in 32 out of 50 study patients. The sensitivity of the Peguero-Lo Presti criterion in detecting LVH was improved (55% vs. 9–34%) at lower specificity (72% vs. 78–100%) in comparison to 8 single traditional ECG-LVH criteria. Additionally, the positive predictive value (77% vs. 72%), positive likelihood ratio (2.0 vs. 1.5), and odds ratio (3.2 vs. 2.4) were higher for the Peguero-Lo Presti criterion versus the presence of any of these 8 traditional ECG-LVH criteria. Cohen’s Kappa, a measure of concordance between ECG and echocardiography with regard to LVH, was 0.24 for the Peguero-Lo Presti criterion, −0.01–0.13 for single traditional criteria, and 0.20 for any traditional criterion. However, by the receiver operating characteristics (ROC) curve analysis, the overall ability to discriminate between patients with and without LVH was insignificantly lower for the Peguero-Lo Presti versus Cornell voltage as a continuous variable (area under the ROC curve: 0.65 (95% CI, 0.48–0.81) vs. 0.71 (0.55–0.86), p = 0.5). In conclusion, our preliminary results suggest a slightly better, albeit still low, agreement of the novel Peguero-Lo Presti ECG criterion compared to the traditional ECG-LVH criteria with echocardiographic LVH in severe aortic stenosis.


Sign in / Sign up

Export Citation Format

Share Document