Experimental investigation of shear capacity and damage analysis of thinned end prefabricated concrete purlins strengthened by CFRP composite

2019 ◽  
Vol 229 ◽  
pp. 111399 ◽  
Author(s):  
Lokman Gemi ◽  
Ceyhun Aksoylu ◽  
Şakir Yazman ◽  
Yasin Onuralp Özkılıç ◽  
Musa Hakan Arslan
2021 ◽  
Vol 54 (3) ◽  
Author(s):  
Claudia Casapulla ◽  
Elham Mousavian ◽  
Luca Argiento ◽  
Carla Ceraldi ◽  
Katalin Bagi

AbstractIncreasing interest has recently been devoted to interlocking blocks/interfaces capable to enhance the sliding resistance of masonry joints to external forces. In this framework, this paper deals with the assessment of the torsion-shear capacity of the contact interface between the lock and the main body of an interlocking block, assumed to have a cohesive behaviour. The interlocking block is a rigid unit which, on its faces, have square cuboidal locks keeping the adjacent/overlapped blocks together and preventing blocks from sliding. Two numerical approaches and a novel ad hoc experimental investigation are proposed to simulate the torsion-shear behaviour by applying eccentrical shear forces to the lock. First, concave, convex and corrected concave formulations provided by the literature for assemblages of rigid blocks with conventional planar joints are extended to model the interlocking block behaviour. Then, according to a second approach based on the discrete element method, the concave-shaped interlocking block is modelled by convex polyhedrons representing the lock and the main body of the block, considered as individual rigid units stacked over each other with a cohesive contact in between. A novel experimental investigation on the limiting pure shear and torsion-shear combinations at the lock interface made of cohesive material is also presented. Two different mortars were chosen to make the specimens, which were casted using 3D printed moulds, and different test configurations were set up to simulate shear and torsion-shear failures. The analytical and numerical results are compared with each other and against the experimental ones, with interesting remarks on the application of the different approaches.


2019 ◽  
Vol 5 (3) ◽  
pp. 528 ◽  
Author(s):  
Maroua Mohammed Majeed ◽  
Aamer Najim Abbas

This paper presents an experimental investigation on the punching shear strength of reinforced concrete flat plate slabs with shearhead collars. Eight reinforced concrete slab specimens were casted and tested under static load test, the load was applied at the center of slab by 100x100 mm steel column. The effect of the shapes, diameter and number of stiffeners has been discovered for shearheads through studying its effect on the load-deflection behavior, ultimate capacity, cracking load, failure mode, stiffness, ductility and energy absorption of tested specimens. The experimental results indicates that using square shearhead had achieved a slight increase in punching shear strength about 3% over that circular shearhead using the same surface area. Also, utilize 550 mm shearhead diameter will contribute to increase the punching shear strength about 14.5%. The increase in the number of stiffeners in specimen (CS4) had reduced the ultimate punching shear capacity by 20.3% over reference specimen. The first crack was decreased from 12.5kN to 7.5kN, when increases the number of stiffeners from one to two. The cracking load was increased with the increase of the diameter of circular shearhead from 10kN to 15Kn in specimens of 336mm and 550mm respectively. The specimen with 336mm diameter and 30mm height circular shearhead achieved 427 kN.m energy absorption, it is higher than the energy absorption of reference specimen by 2.6%. Also, using two stiffeners improved the energy absorption by 110.2% higher than the specimen with one stiffener.


Sign in / Sign up

Export Citation Format

Share Document