Structural performances of thermally conditioned PBO FRCM confined concrete cylinders

2017 ◽  
Vol 176 ◽  
pp. 1096-1106 ◽  
Author(s):  
Luciano Ombres
Author(s):  
Eunsoo Choi ◽  
Yeon-Wook Kim ◽  
Young-Soo Chung ◽  
Hong-Taek Kim ◽  
Baik-Soon Cho

Shape memory alloy (SMA) wire jackets for concrete are distinct from the conventional jackets of steel or FRP since they provide active confinement that can be easily archived due to the shape memory effect of SMAs. This study uses NiTiNb SMA wires of 1.0 mm diameter to confine concrete cylinder with the dimension of 300 mm × 150 mm (L × D). The NiTiNb SMAs have a relative wider temperature hysteresis than NiTi SMAs and, thus, are more applicable for severe temperature-variation environment which civil structures are exposed to. Steel jackets of passive confinement are also prepared to compare the cyclic behavior of active and passive confined concrete cylinders. For this purpose, monotonic and cyclic compressive loading tests are conducted to obtain axial and circumferential strain. The both of strains are used to estimate volumetric strains of concrete cylinders. Also, plastic strains from cyclic behavior are also estimated. For the NiTiNb SMA jacketed cylinders, the monotonic axial behavior differs from the envelope of cyclic behavior; this should be studied in future. The plastic strains of the active confined concrete show a similar trend to those of the passive confinement. The trend of plastic strain of this study does not match with that of CFRP (Carbon Fiber Reinforce Polymer) jackets. For the volumetric strain, the active jackets of the NiTiNb SMA wires provide more energy dissipation than the passive jacket of steel.


Materials ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1227 ◽  
Author(s):  
Chenkai Hong ◽  
Hui Qian ◽  
Gangbing Song

Superelastic shape memory alloy (SMA) exhibits the ability to undergo large deformations before reverting back to its undeformed shape following the removal of the load. This unique property underlies its great potential in the seismic design and retrofitting of structure members. In this paper, superelastic SMA wires were utilized to confine concrete cylinders to enhance their axial compressive behavior. The axial carrying and deformation capacities of SMA-confined concrete cylinders are assessed by uniaxial compression testing on a total of eight SMA-confined concrete columns and one unconfined column. The influence of the amount of SMA and the prestrain level of SMA wires, as well as the reinforcing mode, on the axial carrying and deformation capacity of confined concrete columns were considered. The analysis focuses on the axial carrying capacity and deformation performance of concrete columns reinforced with superelastic SMA under different loading conditions. Based on the experimental data and analysis results, it is found that superelastic SMA wires can increase the axial loading capacity and enhance deformation performance of concrete columns. Under the same loading condition, the ultimate bearing capacity of SMA-confined concrete columns increases as the increasing of the amount of SMA wire. The results of this study verify the effectiveness of superelastic SMA in enhancing the loading capacity and deformation behavior of concrete cylinders.


2016 ◽  
Vol 86 (15) ◽  
pp. 1606-1615 ◽  
Author(s):  
Liang Huang ◽  
Xinrui Yang ◽  
Libo Yan ◽  
Kai He ◽  
Hang Li ◽  
...  

2013 ◽  
Vol 351-352 ◽  
pp. 650-653 ◽  
Author(s):  
Thomas Vincent ◽  
Togay Ozbakkloglu

This paper presents an experimental investigation on the influence of confinement method and specimen end condition on axial compressive behavior of fiber reinforced polymer (FRP)-confined concrete. A total of 12 aramid FRP (AFRP)-confined concrete specimens with circular cross-sections were tested. Half of these specimens were manufactured as concrete-filled FRP tubes (CFFTs) and the remaining half were FRP-wrapped concrete cylinders. The effect of specimen end condition was examined on both CFFTs and FRP-wrapped specimens. This parameter was selected to study the influence of loading the FRP jacket on the axial compressive behavior. In this paper the experimentally recorded stress-strain relationships are presented graphically and key experimental outcomes discussed. The results indicate that the performance of FRP-wrapped specimens is similar to that of CFFT specimens and the influence of specimen end condition is negligible.


2013 ◽  
Vol 12 (4) ◽  
pp. 499-518
Author(s):  
Xinglang Fan ◽  
Zhimin Wu ◽  
Yufei Wu ◽  
Jianjun Zheng

2005 ◽  
Vol 32 (1) ◽  
pp. 279-288 ◽  
Author(s):  
Y-F Li ◽  
S-H Chen ◽  
K-C Chang ◽  
K-Y Liu

In this paper, a total of 60 concrete cylinders 30 cm in diameter and 60 cm in length confined by steel jackets of different thicknesses and different types of lateral steel reinforcements are tested to obtain the stress–strain curves of the cylinders. A constitutive model is proposed to describe the behavior of concrete confined by steel reinforcement, steel jackets, and both steel reinforcement and steel jackets used to retrofit and strengthen reinforced concrete structures. The confined concrete stress–strain curve of the proposed model is divided into two regions: the curve in the first region is approximated using a second-order polynomial equation, and that in the second region using an nth-order power-law equation, where n is a function of the unconfined concrete strength and the lateral confining stress. The results of the experiments show that different types of lateral steel reinforcement contribute greatly to the compressive strength of concrete cylinders confined by the reinforcement. Comparing the stress–strain curves of the uniaxial test with that from the proposed model, we conclude that the proposed model for concrete confined by a steel jacket and lateral steel reinforcement can predict the experimental results very well.Key words: constitutive model, steel jacket, confined concrete.


Sign in / Sign up

Export Citation Format

Share Document