Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging

2017 ◽  
Vol 152 ◽  
pp. 45-52 ◽  
Author(s):  
Min Seok Lee ◽  
Chul Hee Park ◽  
Moon Gi Kang
Author(s):  
Jufriadif Na'am ◽  
Johan Harlan ◽  
Sarifuddin Madenda ◽  
Julius Santony ◽  
Catur Suharinto

<span>Panoramic X-Ray produces produces the most common oral digital radiographic image that it used in dentistry practice. The image can further improve accuracy compared to analog one. This study aims to establish proximal caries edge on enhancement images so they can be easily recognized. The images were obtained from the Department of Radiology, General Hospital of M. Djamil Padang Indonesia. Total file of images to be tested were 101. Firstly, the images are analyzed by dentists who practiced at Segment Padang Hospital Indonesia. They concluded that there is proximal caries in 30 molar teeth. Furthermore, the images were processed using Matlab software with the following steps, i.e. cropping, enhancement, edge detection, and edge enhancement. The accuracy rate of detection of edge enhancement images being compared with that of dentist analysis was 73.3%. In the edge enhancement images proximal caries edge can be found conclusively in 22 teeth and dubiously in eight teeth. The results of this study convinced that edge enhancement images can be recommended to assist dentists in detecting proximal caries. </span>


Author(s):  
T. Oikawa ◽  
N. Mori ◽  
T. Katoh ◽  
Y. Harada ◽  
J. Miyahara ◽  
...  

The “Imaging Plate”(IP) is a highly sensitive image recording plate for X-ray radiography. It has been ascertained that the IP has superior properties and high practicability as an image recording material in a TEM. The sensitivity, one of the properties, is about 3 orders higher than that of conventional photo film. The IP is expected to be applied to low dose techniques. In this paper, an estimation of the quantum noise on the TEM image which appears in case of low electron dose on the IP is reported.In this experiment, the JEM-2000FX TEM and an IP having the same size as photo film were used.Figure 1 shows the schematic diagram of the total system including the TEM used in this experiment. In the reader, He-Ne laser light is scanned across the IP, then blue light is emitted from the IP.


Author(s):  
John A. Hunt ◽  
Richard D. Leapman ◽  
David B. Williams

Interactive MASI involves controlling the raster of a STEM or SEM probe to areas predefined byan integration mask which is formed by image processing, drawing or selecting regions manually. EELS, x-ray, or other spectra are then acquired while the probe is scanning over the areas defined by the integration mask. The technique has several advantages: (1) Low-dose spectra can be acquired by averaging the dose over a great many similar features. (2) MASI can eliminate the risks of spatial under- or over-sampling of multiple, complicated, and irregularly shaped objects. (3) MASI is an extremely rapid and convenient way to record spectra for routine analysis. The technique is performed as follows:Acquire reference imageOptionally blank beam for beam-sensitive specimensUse image processor to select integration mask from reference imageCalculate scanning path for probeUnblank probe (if blanked)Correct for specimen drift since reference image acquisition


Author(s):  
T.W. Jeng ◽  
W. Chiu

With the advances in preparing biological materials in a thin and highly ordered form, and in maintaining them hydrated under vacuum, electron crystallography has become an important tool for biological structure investigation at high resolution (1,2). However, the electron radiation damage would limit the capability of recording reflections with low intensities in an electron diffraction pattern. It has been demonstrated that the use of a low temperature stage can reduce the radiation damage effect and that one can expose the specimen with a higher dose in order to increase the signal contrast (3). A further improvement can be made by selecting a proper photographic emulsion. The primary factors in evaluating the suitability of photographic emulsion for recording low dose diffraction patterns are speed, fog level, electron response at low electron exposure, linearity, and usable range of exposure. We have compared these factors with three photographic emulsions including Kodak electron microscopic plate (EMP), Industrex AA x-ray film (AA x-ray) and Kodak nuclear track film (NTB3).


2021 ◽  
pp. 2004391
Author(s):  
Youbin Li ◽  
Mingyang Jiang ◽  
Zhiming Deng ◽  
Songjun Zeng ◽  
Jianhua Hao
Keyword(s):  
Low Dose ◽  
X Ray ◽  

Dose-Response ◽  
2017 ◽  
Vol 15 (1) ◽  
pp. 155932581769753 ◽  
Author(s):  
Shuji Kojima ◽  
Mitsutoshi Tsukimoto ◽  
Noriko Shimura ◽  
Hironobu Koga ◽  
Akishisa Murata ◽  
...  

There is considerable evidence from experimental studies in animals, as well as from clinical reports, that low-dose radiation hormesis is effective for the treatment of cancer and ulcerative colitis. In this study, we present 3 case reports that support the clinical efficacy of low-dose radiation hormesis in patients with these diseases. First, a patient with prostate cancer who had undergone surgical resection showed a subsequent increase in prostate-specific antigen (PSA). His PSA value started decreasing immediately after the start of repeated low-dose X-ray irradiation treatment and remained low thereafter. Second, a patient with prostate cancer with bone metastasis was treated with repeated low-dose X-ray irradiation. His PSA level decreased to nearly normal within 3 months after starting the treatment and remained at the low level after the end of hormesis treatment. His bone metastasis almost completely disappeared. Third, a patient with ulcerative colitis showed a slow initial response to repeated low-dose irradiation treatment using various modalities, including drinking radon-containing water, but within 8 months, his swelling and bleeding had completely disappeared. After 1 year, the number of bowel movements had become normal. Interest in the use of radiation hormesis in clinical practice is increasing, and we hope that these case reports will encourage further clinical investigations.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Yusuf Özbek ◽  
Michael Vogele ◽  
Christian Plattner ◽  
Pedro Costa ◽  
Mario Griesser ◽  
...  

AbstractFluoroscopy-guided percutaneous biopsy interventions are mostly performed with traditional free-hand technique. The practical experience of the surgeon influences the duration of the intervention and the radiation exposure for patients and him-/herself. Especially when the placement of heavy and long instruments in double oblique angles is required, manual techniques reach their technical limitations very fast. The system presented herein automatizes the needle positioning using only two 2D scans while the robotic platform guides the intervention. These two images were used to plan the needle pathway and to estimate the pose of the robot using a custom-made end-effector with embedded registration fiducials. The estimated pose was subsequently used to transfer the planed needle path to the robot’s coordinate system and finally to compute the movement parameters in order to align the robot with this plan. To evaluate the system, two phantoms with 11 different targets on it were developed. The targets were punctured, and the application accuracy was measured quantitatively. The solution achieved sub-millimetric accuracy for needle placement (min. 0.23, max. 1.04 in mm). Our approach combines the advantages of fluoroscopic imaging and ensures automatic needle alignment with highly reduced X-ray radiation. The proposed system shows promising potential to be a guidance platform that is easy to combine with available fluoroscopic imaging systems and provides valuable help to the physician in more difficult interventions.


Sign in / Sign up

Export Citation Format

Share Document