Objective and subjective evaluation of the performance of medical contact lenses fitted using a contact lens selection algorithm

2016 ◽  
Vol 39 (4) ◽  
pp. 298-306 ◽  
Author(s):  
Esther-Simone Visser ◽  
Robert P.L. Wisse ◽  
Nienke Soeters ◽  
Saskia M. Imhof ◽  
Allegonda Van der Lelij
2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Waleed Ali Abou Samra ◽  
Amani E. Badawi ◽  
Hanem Kishk ◽  
Ayman Abd El ghafar ◽  
Mohamed M. Elwan ◽  
...  

Objectives. To study the fitting and the visual rehabilitation obtained with a corneoscleral contact lens, namely, Rose K2 XL in patients with irregular cornea.Methods. This prospective study included 36 eyes of 36 patients with irregular cornea fitted with Rose K2 XL. Refractive and visual outcomes and mesopic and aberrometric parameters of fitted eyes were assessed at 2 weeks, 3 months, and 6 months after the initial lens use. Objective and subjective parameters of patient satisfaction and lens comfort were noted. Causes of lens discontinuation and complications were also recorded.Results. Average logMAR VA improved significantly from 0.95 ± 0.09 without correction to 0.04 ± 0.05 six months after lens wear. Similarly, mesopic and aberrometric measures were significantly improved. Statistical analysis of the subjective patients’ responses showed a significant acceptance of the lens by most of them. At the end of follow-up, the mean wearing time was 9.9 ± 2.9 hours per day. The most common cause of wearing discontinuation was persistent discomfort (16.7%) and high lens expenses(16.7%). Self-assessed questionnaire showed statistically significant improvement in nearly all measured subjective parameters.Conclusion. Rose K2 XL lenses provide patients with irregular cornea with both quantitative and qualitative optimal visual function with high degree of patient comfort and satisfaction.


The Eye ◽  
2020 ◽  
Vol 22 (129) ◽  
pp. 44-46
Author(s):  
Mark Eddleston

Optimum Infinite is a new GP contact lens material, with an oxygen permeability of 180 barrer and was launched by Contamac at the GSLS 2019. This article provides an insight into the development and characteristics of this breakthrough material.


2019 ◽  
Vol 139 (11) ◽  
pp. 385-392
Author(s):  
Yusuke Tahara ◽  
Zhang Shiyu ◽  
Rui Yatabe ◽  
Rumina Obi ◽  
Chie Okamura ◽  
...  

2020 ◽  
Vol 3 (8) ◽  
pp. 20-22
Author(s):  
Muhammad Hamza ◽  
Chrishan Gunasekera ◽  
Samar Nahas ◽  
Z CX Lin ◽  
Hatch Mukherjee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document