Giant Pseudoaneurysm of the Ascending Aorta Caused by Chronic Stanford Type A Aortic Dissection

2011 ◽  
Vol 27 (6) ◽  
pp. 871.e3-871.e4
Author(s):  
Alexander Weymann ◽  
Bastian Schmack ◽  
Matthias Karck ◽  
Gábor Szabó
2011 ◽  
Vol 14 (6) ◽  
pp. 373 ◽  
Author(s):  
Saina Attaran ◽  
Maria Safar ◽  
Hesham Zayed Saleh ◽  
Mark Field ◽  
Manoj Kuduvalli ◽  
...  

<p>Management of acute Stanford type A aortic dissection remains a major surgical challenge. Directly cannulating the ascending aorta provides a rapid establishment of cardiopulmonary bypass but consists of risks such as complete rupture of the aorta, false lumen cannulation, subsequent malperfusion and propagation of the dissection.</p><p>We describe a technique of cannulating the ascending aorta in patients with acute aortic dissection that can be performed rapidly in hemodynamically unstable patients under ultrasound-epiaortic and transesophageal (TEE) guidance.</p>


2016 ◽  
Vol 24 (1) ◽  
pp. 75-80 ◽  
Author(s):  
Tilo Kölbel ◽  
Christian Detter ◽  
Sebastian W. Carpenter ◽  
Fiona Rohlffs ◽  
Yskert von Kodolitsch ◽  
...  

Purpose: To describe the combined use of a tubular stent-graft for the ascending aorta and an inner-branched arch stent-graft for patients with acute type A aortic dissection. Technique: The technique to deploy these modular, custom-made stent-grafts is demonstrated in 2 patients with acute DeBakey type I aortic dissections and significant comorbidities precluding open surgery. Both emergent procedures were made possible by the availability of suitable devices manufactured for elective repair in other patients. After preliminary carotid-subclavian bypass, a long Lunderquist guidewire was introduced from the right femoral artery to the left ventricle for delivery of the Zenith Ascend and Zenith Branched Arch Endovascular Grafts under inflow occlusion. Bridging stent-grafts were delivered to the innominate and left common carotid arteries to connect to the 2 inner branches; the left subclavian artery was occluded. Both cases were technically successful and resulted in exclusion of the false lumen in the ascending aorta. The operating and fluoroscopy times did not exceed those of comparable elective procedures. The patients were rapidly extubated shortly after the procedure and without serious immediate complications. One patient survived 11 months with a satisfactory repair; the other succumbed to complications of recurrent pneumonia after 23 days. Conclusion: Endovascular treatment of patients with acute type A aortic dissection using a combination of tubular and branched stent-grafts in the ascending aorta is feasible and offers an alternative strategy to open surgery.


Author(s):  
Helen Hashemi ◽  
Sahil Khera ◽  
Malcolm Anastasius ◽  
Ismail El-Hamamsy ◽  
Gilbert H.L. Tang ◽  
...  

2017 ◽  
Vol 25 (1) ◽  
pp. 47-51 ◽  
Author(s):  
Tadashi Kitamura ◽  
Shinzo Torii ◽  
Tetsuya Horai ◽  
Koichi Sughimoto ◽  
Yusuke Irisawa ◽  
...  

2019 ◽  
Vol 108 (2) ◽  
pp. 481-490 ◽  
Author(s):  
Takashi Yamauchi ◽  
Hiroshi Takano ◽  
Toshiki Takahashi ◽  
Takafumi Masai ◽  
Masayuki Sakaki ◽  
...  

2016 ◽  
Vol 4 (1) ◽  
pp. 15
Author(s):  
Xiao-yan Chen ◽  
Fan-liang Kong ◽  
Tong-guo Wu

Type A aortic dissection is a catastrophic clinical entity involving the ascending aorta. In this case report, a patient was admitted to the emergency room with a presentation resembling acute myocardial infarction (AMI) that led to the inappropriate administration of anticoagulant agents or platelet. This is a case report of a 69-year-old male patient with early misdiagnosis and analysis of type A aortic dissection with discussion on the causes of misdiagnosis in light of the literature.


Author(s):  
Piergiorgio Tozzi ◽  
Ziyad Gunga ◽  
Lars Niclauss ◽  
Dominique Delay ◽  
Aurelian Roumy ◽  
...  

Abstract OBJECTIVES Current guidelines recommend prophylactic replacement of the ascending aorta at an aneurysmal diameter of &gt;55 mm to prevent acute Type A aortic dissection (TAAD) in non-Marfan patients. Several publications have challenged this threshold, suggesting that surgery should be performed in smaller aneurysms to prevent this devastating disease. We reviewed our experience with measuring aortic size at the time of TAAD to validate the existing recommendation for prophylactic ascending aorta replacement. METHODS All patients who had been admitted for TAAD to our emergency department from 2014 to 2019 and underwent ascending aorta replacement were included. Marfan patients were excluded. The maximum diameter of the dissected aorta was measured preoperatively using CT scan. We estimated the aortic diameter at the time of dissection to be 7 mm smaller than the measured maximum diameter of the dissected aorta (modelled pre-dissection diameter). RESULTS Overall, 102 patients were included. Of these, 67 were male (65.6%) and 35 were female (34.4%), and the cohort’s mean age was 65 ± 12.1 years. In addition, 66% were treated for arterial hypertension. The mean maximum modelled pre-dissection diameter was 39.6 ± 4.8 mm: 39.1 ± 5.1 mm in men and 40.7 ± 2.8 mm in women (P = 0.1). The cumulative 30-day mortality rate was 19.6% (20/102). CONCLUSIONS TAAD occurred at a modelled aortic diameter below 45 mm in 87.7% of our patients. Therefore, the current aortic diameter threshold of 55 mm excludes ∼99% of patients with TAAD from prophylactic replacement of the ascending aorta. The maximum diameter of the ascending aorta warrants reappraisal and this parameter should be a distinct part of a personalized decision-making process that also takes into account age, gender and body surface area to establish the surgical indication for preventive aorta replacement aimed to improve the survival benefit of this procedure.


2012 ◽  
Vol 2012 ◽  
pp. 1-3 ◽  
Author(s):  
Mertay Boran ◽  
Ali İhsan Parlar ◽  
Ertay Boran

Giant pseudoaneurysm of the ascending aorta is a rare but dreadful complication occurring several months or years after aortic surgery. Thoracic aortic aneurysms tend to be asymptomatic and were previously often diagnosed only after a complication such as dissection or rupture. We present a rare case of giant ascending aneurysm with Stanford type A aortic dissection occurring 6 years after aortic valve replacement and also illustrate the potential dimensions the ascending aorta may reach by a pseudoaneurysm and dissection after AVR.