Erratum to “Investigation of surface properties of liquid transition metals: Surface tension and surface entropy” [Appl. Surf. Sci. 257 (2010) 261–265]

2012 ◽  
Vol 258 (15) ◽  
pp. 5923-5924
Author(s):  
S.D. Korkmaz ◽  
Ş. Korkmaz
Entropy ◽  
2020 ◽  
Vol 22 (12) ◽  
pp. 1337
Author(s):  
Xiangfeng Tian ◽  
Lemeng Wang ◽  
Pan Zhang ◽  
Dong Fu

The surface tension and viscosity values of N-methyldiethanolamine (MDEA) aqueous solutions promoted by tetramethylammonium arginate ([N1111][Arg]) were measured and modeled. The experimental temperatures were 303.2 to 323.2 K. The mass fractions of MDEA (wMDEA) and [N1111][Arg] (w[N1111][Arg]) were 0.300 to 0.500 and 0.025 to 0.075, respectively. The measured surface tension and viscosity values were satisfactorily fitted to thermodynamic models. With the aid of experimentally viscosity data, the activation energy (Ea) and H2S diffusion coefficient (DH2S) of MDEA-[N1111][Arg] aqueous solution were deduced. The surface entropy and surface enthalpy of the solutions were calculated using the fitted model of the surface tension. The quantitative relationship between the calculated values (surface tension, surface entropy, surface enthalpy, viscosity, activation energy, and H2S diffusion coefficient) and the operation conditions (mass fraction and temperature) was demonstrated.


Author(s):  
Anpalaki J. Ragavan ◽  
Cahit A. Evrensel ◽  
Peter Krumpe

Altered surface and viscoelastic material properties of mucus during respiratory diseases have a strong influence on its clearance by cilia and cough. Combined effects of the surface properties (contact angle and surface tension) and storage modulus with relatively unchanged viscosity on displacement of the simulated mucus aliquot during simulated cough through a model adult human trachea is investigated. For the mucus simulants used in this study contact angle and surface tension increase significantly as storage modulus increase while viscosity remains practically unchanged. Displacement of mucus simulant aliquots increased significantly with increasing storage modulus (and contact angle) at a given cough velocity in the range between 5 meters/second (m/s) and 30 m/s with duration 0.3 s. Results suggest that the interactive effects of elasticity and surface properties may help facilitate mucus displacement at low cough velocities.


PEDIATRICS ◽  
1987 ◽  
Vol 79 (1) ◽  
pp. 38-46
Author(s):  
Machiko Ikegami ◽  
Yotaro Agata ◽  
Tarek Elkady ◽  
Mikko Hallman ◽  
David Berry ◽  
...  

Natural sheep surfactant, rabbit surfactant, human surfactant, and surfactant TA were compared for in vitro surface properties and for responses of preterm lambs to treatment. Equivalent amounts of sheep, rabbit, and human surfactants were needed to lower the surface tension to less than 10 dynes/cm, whereas four times less surfactant TA similarly lowered the surface tension. Surface-spreading rates were similar for the surfactants. The surface adsorption of the batch of human surfactant tested was much slower than was adsorption of the other surfactants. Ventilation was significantly improved in all surfactant-treated lambs relative to the control lambs, indicating the general efficacy of the surfactant treatments. Overall, surfactant TA had the best in vitro characteristics, yet the preterm lambs treated at birth with surfactant TA had lower Po2 values and higher ventilatory requirements than did the sheep surfactant-treated lambs. The in vivo responses to rabbit surfactant were intermediate between the responses to sheep surfactant and to surfactant TA. Human surfactant resulted in the least effective clinical response. More of the phosphatidylcholine associated with human surfactant and surfactant TA was lost from the alveoli and lung tissue after four hours of ventilation than was lost from sheep or rabbit surfactant-treated lambs. More intravascular radiolabeled albumin leaked into the alveoli of the surfactant TA-treated lambs than sheep or rabbit surfactant-treated. lambs. The four surfactants also had different sensitivities to the effects on minimum surface tensions of the soluble proteins present in alveolar washes. The study demonstrates that the range of clinical responses was not predictable based on the in vitro surface properties that we measured. The surfactants behaved differently with respect to loss from the lungs and sensitivity to soluble proteins. Factors other than surface properties are important for the in vivo responses to surfactant treatments.


1989 ◽  
Vol 66 (5) ◽  
pp. 2039-2044 ◽  
Author(s):  
M. R. Mercurio ◽  
J. M. Fiascone ◽  
D. M. Lima ◽  
H. C. Jacobs

In vitro surface properties of pulmonary surfactant thought to be essential to its ability to increase pulmonary compliance include minimum surface tension less than 10 dyn/cm and large surface tension variability and hysteresis. We tested four surface-active agents (Tween 20, a detergent; and FC-100, FC-430, and FC-431, industrial fluorocarbons), all lacking these properties, for their ability to increase pulmonary compliance in surfactant-deficient premature rabbits. Fetal rabbits were delivered by cesarean section at 27 days (full term = 31 days) and injected via tracheostomy with 50% lactated Ringer solution, adult rabbit surfactant, or one of the four experimental agents. Dynamic compliance was measured using 1 h of mechanical ventilation followed by alveolar lavage. Each experimental agent produced a dynamic compliance significantly higher than 50% lactated Ringer solution and statistically equal to or greater than natural surfactant. Equilibrium surface tension of the agents and minimum and equilibrium surface tension of the alveolar washes each correlated with compliance (P less than 0.05). This suggests that some surface properties of pulmonary surfactant believed to be essential are not, although surface tension does seem to play a role in pulmonary compliance.


Sign in / Sign up

Export Citation Format

Share Document