scholarly journals On short-length error-correcting codes for 5G-NR

2018 ◽  
Vol 79 ◽  
pp. 53-62 ◽  
Author(s):  
Johannes Van Wonterghem ◽  
Amira Alloum ◽  
Joseph Jean Boutros ◽  
Marc Moeneclaey
2018 ◽  
Vol 2 (1) ◽  
pp. 45-54
Author(s):  
Qurotul Aini ◽  
Siti Ria Zuliana ◽  
Nuke Puji Lestari Santoso

The scale is usually used to check and determine the value of a qualitative factor in quantitative measures. The measurement scale is a management in agreement that is used as a reference to determine the short length of the interval that is in the measuring instrument, so that the measuring instrument when used in measurements will produce quantitative data. The results of the scale management calculation must be interpreted carefully because in addition to producing a rough picture, the respondent's answers are not just straightforward to be trusted. Types of measurement scales: Likert scale, Guttman scale, semantic differential scale, rating scale, Thurstone scale, Borgadus scale, and various other measurement management scales. One of the most difficult jobs for information technology researchers faced with the necessity of measuring variables is: finding directions in the midst of many existing sizes. If there is a good size for a particular variable, it seems that there are not many reasons to compile a new size yourself. Keywords: Scale, Measurement, Variables.


1988 ◽  
Vol 24 (5) ◽  
pp. 292
Author(s):  
O.W. Ata ◽  
T.M. Benson
Keyword(s):  

Author(s):  
Mohammad Rizk Assaf ◽  
Abdel-Nasser Assimi

In this article, the authors investigate the enhanced two stage MMSE (TS-MMSE) equalizer in bit-interleaved coded FBMC/OQAM system which gives a tradeoff between complexity and performance, since error correcting codes limits error propagation, so this allows the equalizer to remove not only ICI but also ISI in the second stage. The proposed equalizer has shown less design complexity compared to the other MMSE equalizers. The obtained results show that the probability of error is improved where SNR gain reaches 2 dB measured at BER compared with ICI cancellation for different types of modulation schemes and ITU Vehicular B channel model. Some simulation results are provided to illustrate the effectiveness of the proposed equalizer.


2021 ◽  
pp. 1-11
Author(s):  
Kusan Biswas

In this paper, we propose a frequency domain data hiding method for the JPEG compressed images. The proposed method embeds data in the DCT coefficients of the selected 8 × 8 blocks. According to the theories of Human Visual Systems  (HVS), human vision is less sensitive to perturbation of pixel values in the uneven areas of the image. In this paper we propose a Singular Value Decomposition based image roughness measure (SVD-IRM) using which we select the coarse 8 × 8 blocks as data embedding destinations. Moreover, to make the embedded data more robust against re-compression attack and error due to transmission over noisy channels, we employ Turbo error correcting codes. The actual data embedding is done using a proposed variant of matrix encoding that is capable of embedding three bits by modifying only one bit in block of seven carrier features. We have carried out experiments to validate the performance and it is found that the proposed method achieves better payload capacity and visual quality and is more robust than some of the recent state-of-the-art methods proposed in the literature.


2021 ◽  
Vol 344 (2) ◽  
pp. 112199
Author(s):  
Christian Deppe ◽  
Vladimir Lebedev

2021 ◽  
Vol 8 ◽  
pp. 237437352110114
Author(s):  
Andrew Nyce ◽  
Snehal Gandhi ◽  
Brian Freeze ◽  
Joshua Bosire ◽  
Terry Ricca ◽  
...  

Prolonged waiting times are associated with worse patient experience in patients discharged from the emergency department (ED). However, it is unclear which component of the waiting times is most impactful to the patient experience and the impact on hospitalized patients. We performed a retrospective analysis of ED patients between July 2018 and March 30, 2020. In all, 3278 patients were included: 1477 patients were discharged from the ED, and 1680 were admitted. Discharged patients had a longer door-to-first provider and door-to-doctor time, but a shorter doctor-to-disposition, disposition-to-departure, and total ED time when compared to admitted patients. Some, but not all, components of waiting times were significantly higher in patients with suboptimal experience (<100th percentile). Prolonged door-to-doctor time was significantly associated with worse patient experience in discharged patients and in patients with hospital length of stay ≤4 days. Prolonged ED waiting times were significantly associated with worse patient experience in patients who were discharged from the ED and in inpatients with short length of stay. Door-to-doctor time seems to have the highest impact on the patient’s experience of these 2 groups.


Sign in / Sign up

Export Citation Format

Share Document