Press fit condylar total knee arthroplasty: radiographic evaluation at a 5-year follow-up

2002 ◽  
Vol 3 (3) ◽  
pp. 157-162 ◽  
Author(s):  
G. Sandrucci ◽  
E. Cenna ◽  
M. Favuto ◽  
A. Bistolfi ◽  
M. Crova
1993 ◽  
Vol 42 (2) ◽  
pp. 601-605
Author(s):  
Kenji Kubota ◽  
Hiroshi Mizuta ◽  
Koichi Kai ◽  
Eiichi Nakamura ◽  
Minoru Shiraishi ◽  
...  

2013 ◽  
Vol 28 (8) ◽  
pp. 1286-1290 ◽  
Author(s):  
Shantanu S. Patil ◽  
George Branovacki ◽  
Mersadies R. Martin ◽  
Pamela A. Pulido ◽  
Yadin D. Levy ◽  
...  

2001 ◽  
Vol 36 (3) ◽  
pp. 245
Author(s):  
Hyun Kee Chung ◽  
Choong Hyeok Choi ◽  
Kyoung Tae Kim ◽  
Yong Jin Cho

Author(s):  
Guillaume Laforest ◽  
Lazaros Kostretzis ◽  
Marc-Olivier Kiss ◽  
Pascal-André Vendittoli

Abstract Purpose While kinematic alignment (KA) total knee arthroplasty (TKA) with cemented implants has been shown to provide equivalent or better results than mechanical alignment, its combination with cementless fixation has not yet been documented. The purpose of this study is to report (1) revision rate and causes, (2) clinical results based on patient report outcome measures (PROMs), and (3) radiological signs of implant dysfunction in patients with an uncemented TKA implanted with restricted KA (rKA), after a minimum follow-up of 2 years. Methods This study included the first 100 consecutive uncemented cruciate retaining TKAs implanted between November 2015 and February 2018 by a single surgeon following rKA principles. At last follow-up, all adverse events and PROMs assessed by WOMAC, KOOS, and FJS scores were documented. Radiographic evaluation was performed to identify signs of implant loosening. Results After a mean follow-up of 49 months (32, 60), no implant revision was performed for aseptic loosening. Three revisions were performed: one for malalignment, one for a deep infection, and one for instability. The mean WOMAC score was 20.1 (0–79, 21.3), the mean KOOS score was 71.5 (19.0–96.6, 19.8), and the mean FJS score was 65.9 (0–100, 29.6). No radiological evidence of implant aseptic loosening or osteolysis was identified. Conclusion This study shows that in 99% of our cases, rKA combined with the tested cementless TKA implant allowed for adequate secondary fixation and good functional outcomes in the short term. Favourable mid- to long-term implant survivorship is anticipated. Level of evidence III.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Ekasame Vanitcharoenkul ◽  
Aasis Unnanuntana

Abstract Background The ATTUNE Knee System is a new prosthetic design that has theoretical advantages over the Press Fit Condylar (PFC) Sigma Knee System specific to improved knee kinematics and patellofemoral joint tracking. This study aimed to evaluate functional outcomes compared between the ATTUNE and PFC Sigma designs at a minimum follow-up of 5 years. Methods We retrospectively reviewed data from total knee arthroplasty (TKA) patients who received either the ATTUNE or PFC Sigma system during November 2013 to February 2015 at Siriraj Hospital (Bangkok, Thailand). Functional outcomes were evaluated using Timed Up and Go (TUG) test, 2-min walk test (2MWT), modified knee score, numerical rating scale-pain, range of motion (ROM), and rate of anterior knee pain and crepitation at preoperation, 3-months, 1-year, and 5-years postoperatively. Results Of 113 patients, 59 and 54 received the PFC Sigma and ATTUNE systems, respectively. At a minimum of 5-years follow-up, all functional outcomes improved significantly from the preoperative period although TUG test and 2MWT declined significantly from 1- to 5-years postoperatively only in the PFC Sigma group. The mean ROM at 5-years postoperatively was significantly higher in ATTUNE than in PFC Sigma; however, the difference was small (116° vs. 110°, respectively; p = 0.041). There were no significant differences in any of the other outcome measurements, including anterior knee pain, clunking, and crepitation, between groups at any study time point. Conclusions ​Our results revealed no major differences in functional outcomes between the PFC Sigma and ATTUNE TKA designs at an intermediate-term follow-up of at least 5 years. Longer-term follow-up study is needed to evaluate the benefits of the ATTUNE design relative to polyethylene wear and the rate of aseptic loosening.


2017 ◽  
Vol 30 (09) ◽  
pp. 930-935 ◽  
Author(s):  
Jared Newman ◽  
Anton Khlopas ◽  
Morad Chughtai ◽  
Chukwuweike Gwam ◽  
Jaydev Mistry ◽  
...  

AbstractSome surgeons have been hesitant to use cementless fixation for total knee arthroplasty (TKA) in elderly patients due to concerns regarding successful bone biological fixation. Therefore, this study evaluated: (1) implant survivorship, (2) functional outcomes, (3) radiographic outcomes, and (4) complications in patients over 75 years of age who underwent cementless total knee arthroplasty. A total of 134 patients (142 TKAs) older than 75 years at a single institution between June 2008 and June 2014 were retrospectively reviewed. Their mean follow-up was 4 years (range: 2–8 years). The cohort consisted of 91 women and 43 men who had a mean age of 80 years (range: 76 to 88 years). The preoperative diagnoses were osteoarthritis (n = 107 patients), rheumatoid arthritis (n = 21 patients), and osteonecrosis (n = 6 patients). Descriptive statistics were used to calculate the means and ranges and a Kaplan-Meier analysis was performed to determine the aseptic and all cause implant survivorship. Radiographic evaluation was performed using the new Knee Society Radiographic Evaluation and Scoring System. Functional outcomes at the final follow-up as well as all medical and surgical complications were recorded for each patient. The aseptic implant survivorship was 99.3% (95% CI: 7.9–8.1), and the all cause implant survivorship was 98.6% (95% CI: 7.9–8.1). There was one aseptic revision and one septic revision. At the latest follow-up the mean Knee Society pain score was 93 points (range, 80–100 points), and the mean Knee Society function score was 84 points (range, 70–90 points). On radiographic evaluation, there were no progressive radiolucencies, subsidence, and loosening of prostheses at the latest follow-up. The use of cementless TKA demonstrated excellent survivorship, mid-term clinical and functional outcomes, as well as no progressive radiolucencies or subsidence in patients older than 75 years. In addition, there was a low rate of surgical and medical complications. Therefore, cementless TKA may be a good option for patients older than 75 years.


2021 ◽  
Author(s):  
Ekasame Vanitcharoenkul ◽  
Aasis Unnanuntana

Abstract Background The ATTUNE Knee System is a new prosthetic design that has theoretical advantages over the Press Fit Condylar (PFC) Sigma Knee System specific to improved knee kinematics and patellofemoral joint tracking. This study aimed to evaluate functional outcomes compared between the ATTUNE and PFC Sigma designs at a minimum follow-up of 5 years. Methods ​​We retrospectively reviewed data from total knee arthroplasty patients who received either the ATTUNE or PFC Sigma system during November 2013 to February 2015 at Siriraj Hospital (Bangkok, Thailand). Functional outcomes were evaluated using timed up and go test, 2-minute walk test, modified knee score, numerical rating scale-pain, range of motion (ROM), and rate of anterior knee pain and crepitation at preoperation, 3-months, 1-year, and 5-years, postoperatively. Results Of 113 patients, 59 and 54 received the PFC Sigma and ATTUNE systems, respectively. At a minimum of 5-years follow-up, all functional outcomes improved significantly. Although the mean ROM at 5-years postoperatively was significantly higher in ATTUNE than in PFC Sigma, the difference was small (116° vs. 110°, respectively; p = 0.041). There were no significant differences in any of the other outcome measurements, including anterior knee pain, clunking, and crepitation, between groups at any study time point. Conclusions ​Our results revealed no major differences in functional outcomes between the PFC Sigma and ATTUNE TKA designs at an intermediate-term follow-up of at least 5 years. Longer-term follow-up study is needed to evaluate the benefits of the ATTUNE design relative to polyethylene wear and the rate of aseptic loosening.


Author(s):  
Jung-Won Lim ◽  
Yong-Beom Park ◽  
Dong-Hoon Lee ◽  
Han-Jun Lee

AbstractThis study aimed to evaluate whether manipulation under anesthesia (MUA) affect clinical outcome including range of motion (ROM) and patient satisfaction after total knee arthroplasty (TKA). It is hypothesized that MUA improves clinical outcomes and patient satisfaction after primary TKA. This retrospective study analyzed 97 patients who underwent staged bilateral primary TKA. MUA of knee flexion more than 120 degrees was performed a week after index surgery just before operation of the opposite site. The first knees with MUA were classified as the MUA group and the second knees without MUA as the control group. ROM, Knee Society Knee Score, Knee Society Functional Score, Western Ontario and McMaster Universities (WOMAC) score, and patient satisfaction were assessed. Postoperative flexion was significantly greater in the MUA group during 6 months follow-up (6 weeks: 111.6 vs. 99.8 degrees, p < 0.001; 3 months: 115.9 vs. 110.2 degrees, p = 0.001; 6 months: 120.2 vs. 117.0 degrees, p = 0.019). Clinical outcomes also showed similar results with knee flexion during 2 years follow-up. Patient satisfaction was significantly high in the MUA group during 12 months (3 months: 80.2 vs. 71.5, p < 0.001; 6 months: 85.8 vs. 79.8, p < 0.001; 12 months: 86.1 vs. 83.9, p < 0.001; 24 months: 86.6 vs. 85.5, p = 0.013). MUA yielded improvement of clinical outcomes including ROM, and patient satisfaction, especially in the early period after TKA. MUA in the first knee could be taken into account to obtain early recovery and to improve patient satisfaction in staged bilateral TKA.


2020 ◽  
Vol 106 (3) ◽  
pp. 449-458
Author(s):  
Camille Bauer ◽  
Bogdan Zaharia ◽  
Florent Galliot ◽  
Jauffrey Parot ◽  
Fayçal Houfani ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jake von Hintze ◽  
Mika Niemeläinen ◽  
Harri Sintonen ◽  
Jyrki Nieminen ◽  
Antti Eskelinen

Abstract Background The purpose of this study was to determine the mid-term clinical, radiographic and health-related quality of life (HRQoL) outcomes and define the survival rate in patients who had undergone revision total knee arthroplasty (TKA) using the single rotating hinged knee (RHK) design. Methods Between January 2004 and December 2013, 125 revision TKAs were performed at our institution using the single RHK implant. We conducted both a retrospective analysis of prospectively collected outcome data of these patients and a prospective follow-up study of all 39 living patients (41 knees). The follow-up phase included an optional extra follow-up visit, PROM questionnaires, and plain radiographs. Results The ten-year Kaplan-Meier survival rate of the revision RHK knees was 81.7% (95% CI 71.9–91.6%) with re-revision for any reason as the endpoint. Overall, 15 knees (12% of the total) underwent re-revision surgery during the follow-up. The median follow-up was 6.2 years (range, 0–12.7 years) post-operatively for the baseline group. One mechanical hinge mechanism-related failure occurred without any history of trauma or infection. At the time of the final follow-up, the majority of patients evinced a fairly good clinical outcome measured with patient-reported outcome measures and none of the components were radiographically loose. Conclusion We found that in patients undergoing complex revision TKA, fairly good functional outcome and quality of life can be achieved using an RHK implant. Further, it seems that in this type of patient cohort, revision TKA using an RHK implant relieves pain more than it improves ability to function. The NexGen® RHK design can be regarded as a suitable option in complex revision TKA.


Sign in / Sign up

Export Citation Format

Share Document