From total allowable error via metrological traceability to uncertainty of measurement of the unbiased result

1999 ◽  
Vol 4 (9-10) ◽  
pp. 401-405 ◽  
Author(s):  
René Dybkaer
2010 ◽  
Vol 56 (7) ◽  
pp. 1091-1097 ◽  
Author(s):  
Brad S Karon ◽  
James C Boyd ◽  
George G Klee

Abstract Background: Glucose meter analytical performance criteria required for safe and effective management of patients on tight glycemic control (TGC) are not currently defined. We used simulation modeling to relate glucose meter performance characteristics to insulin dosing errors during TGC. Methods: We used 29 920 glucose values from patients on TGC at 1 institution to represent the expected distribution of glucose values during TGC, and we used 2 different simulation models to relate glucose meter analytical performance to insulin dosing error using these 29 920 initial glucose values and assuming 10%, 15%, or 20% total allowable error (TEa) criteria. Results: One-category insulin dosing errors were common under all error conditions. Two-category insulin dosing errors occurred more frequently when either 20% or 15% TEa was assumed compared with 10% total error. Dosing errors of 3 or more categories, those most likely to result in hypoglycemia and thus patient harm, occurred infrequently under all error conditions with the exception of 20% TEa. Conclusions: Glucose meter technologies that operate within a 15% total allowable error tolerance are unlikely to produce large (≥3-category) insulin dosing errors during TGC. Increasing performance to 10% TEa should reduce the frequency of 2-category insulin dosing errors, although additional studies are necessary to determine the clinical impact of such errors during TGC. Current criteria that allow 20% total allowable error in glucose meters may not be optimal for patient management during TGC.


1997 ◽  
Vol 43 (4) ◽  
pp. 602-607 ◽  
Author(s):  
Curtis A Parvin

Abstract Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another performance measure that naturally fits within the total allowable error paradigm is the probability that a reported test result contains an analytical error that exceeds the total allowable error specification. In general, the out-of-control error conditions associated with the greatest chance of reporting an unacceptable test result are unrelated to the traditionally defined “critical” error conditions. If the probability of reporting an unacceptable test result is used as the primary performance measure, worst-case QC performance can be determined irrespective of the magnitude of any out-of-control error condition that may exist, thus eliminating the need for the concept of a “critical” out-of-control error.


2019 ◽  
Vol 3 (5) ◽  
pp. 864-869 ◽  
Author(s):  
Jasmijn A van Balveren ◽  
Eugenie F A Gemen ◽  
Ron Kusters

Abstract Background Venipuncture for the purpose of blood analysis is often performed at remote locations, and samples may be centrifuged locally to preserve the integrity of analytes. At the central laboratory, these tubes may be centrifuged again in the routine process. However, limited research shows that >1 centrifugation cycle of gel separator tubes causes significant changes in analytes, in particular troponin I and potassium. These preanalytical test changes are undesirable and may lead to errors in diagnosis and treatment of patients. Methods Ten volunteers donated blood in 10 lithium heparin gel tubes. Per volunteer, 5 tubes were centrifuged with Becton Dickinson centrifugation settings and 5 tubes with our local centrifugation settings. For each centrifugation setting, 1 tube was centrifuged directly after venipuncture; the second tube, directly after venipuncture and again after 4 h; the third tube, directly after venipuncture and again after 8 h; the fourth tube, 4 h after venipuncture; the last tube, 8 h after venipuncture. Thirty routine chemistry analyses were performed in plasma directly after the last centrifugation cycle. All tubes were kept at room temperature. Analytes were considered unstable when the mean percentage deviation exceeded the total allowable error. Results Except for calcium, which slightly exceeded the predefined total allowable error limit, all the investigated analytes remained stable up to 8 h after a second centrifugation cycle with both centrifugation settings. Conclusion This study shows that recentrifugation up to 8 h after blood collection does not cause relevant deviations in test results and may be applied safely.


Author(s):  
Ahmed Naseer Kaftan ◽  
Anne Khazal Yaseen ◽  
Zina Hasan

Background: A major target of quality assurance is the minimization of error rates in order to enhance patient safety, six sigma or sigma metrics were used to assess the analytical quality of automated clinical chemistry, six sigma metrics is used in combination with total allowable error, method imprecision and bias. The goal is to attain the highest possible sigma scale within the acceptable limits of total allowable error. For assessment of sigma metrics results of serum glucose and lipid profile and verification of reference values for these analytes tested by automated chemistry analyzer in Medical City hospitals.Methods: In the present study, internal quality control (EQA) and external quality assessment (EQA) data were analyzed for the period from May to July 2017 using chemistry autoanalyzer (Siemens Dimension RxL Max) at the Teaching Laboratories of the Medical City. Mean, standard deviation, coefficient of variation, bias, total error and sigma metrics were calculated for glucose, cholesterol, triglycerides and HDL.Results: Excellent sigma values (≥6) were elicited for triglycerides (10.9), Satisfactory sigma values (≥3) were elicited for cholesterol (3.4) and HDL (3.4), while glucose performed poorly (2.3) on the sigma scale.Conclusions: Sigma metrics helps to assess analytical methodologies and augment laboratory performance. It acts as a guide for planning quality control strategy. It can be a self-assessment tool regarding the functioning of clinical laboratory. Triglycerides was the best performer when it was gauzed on the sigma scale, with a sigma metrics value of 10.9 and glucose had the least sigma metrics value of 2.5 so there is need for improvement and the method should be controlled with greater attention to ensure quality. 


Author(s):  
Jasmijn A van Balveren ◽  
Mirelle JAJ Huijskens ◽  
Eugenie FA Gemen ◽  
Nathalie CV Péquériaux ◽  
Ron Kusters

Background Phlebotomy for the purpose of blood analysis is often performed at remote locations, and samples are usually temporarily stored before transport to a central laboratory for analysis. The circumstances during storage and shipment may not meet the necessary requirements. If analysed anyway, false results may be generated. We therefore examined the influence of precentrifugation time and temperature of the most frequently requested tests in whole blood. Methods Healthy volunteers donated blood in which 48 analytes were tested. Routine chemistry was performed in lithium heparin tubes, haematology in ethylenediaminetetraacetic acid tubes, coagulation in citrate tubes and glucose in sodium fluoride tubes. One tube was measured directly. The others were kept at different temperatures (4, 8, 20 or 30℃) and stored for 4, 6, 8 or 24 h before analysis. Additionally, some analytes were examined at 12, 16, 24 and 28℃. The mean percentage deviation was compared with different decision levels, including the total allowable error. Results When using the total allowable error as an acceptable limit, most of the investigated analytes remained stable. However, bicarbonate is unstable at almost all tested time-points and temperatures. Calcium, lactate dehydrogenase, potassium and sodium are particularly affected at low temperatures, while phosphate is mainly affected at and above room temperature after 8 h. Conclusion We established the influence of time and temperature on a broad range of analytes, which may be applied to set the limits in transportation and storage of whole blood samples.


Sign in / Sign up

Export Citation Format

Share Document