scholarly journals Inter- and intra-reader reproducibility of shear wave elastography measurements for musculoskeletal soft tissue masses

2019 ◽  
Vol 49 (5) ◽  
pp. 779-786
Author(s):  
Jonathan Nicholls ◽  
Abdulrahman M. Alfuraih ◽  
Elizabeth M. A. Hensor ◽  
Philip Robinson

Abstract Objective To determine inter- and intra-reader reproducibility of shear wave elastography measurements for musculoskeletal soft tissue masses. Materials and methods In all, 64 patients with musculoskeletal soft tissue masses were scanned by two readers prior to biopsy; each taking five measurements of shear wave velocity (m/s) and stiffness (kPa). A single lesion per patient was scanned in transverse and cranio-caudal planes. Depth measurements (cm) and volume (cm3) were recorded for each lesion, for each reader. Linear mixed modelling was performed to assess limits of agreement (LOA), inter- and intra-reader repeatability, including analyses for measured depth and volume. Results Of the 64 lesions scanned, 24 (38%) were malignant. Bland-Altman plots demonstrated negligible bias with wide LOA for all measurements. Transverse velocity was the most reliable measure—intraclass correlation (95% CI) = 0.917 (0.886, 1)—though reader 1 measures could be between 38% lower and 57% higher than reader 2 [ratio-scale bias (95% LOA) = 0.99 (0.64, 1.55)]. Repeatability coefficients indicated most disagreement resulted from poor within-reader reproducibility. LOA between readers calculated from means of five repeated measurements were narrower—transverse velocity ratio-scale bias (95% LOA) = 1.00 (0.74, 1.35). Depth affected both estimated velocity and repeatability; volume also affected repeatability. Conclusion This study found poor repeatability of measurements with wide LOA due mostly to intra-reader variability. Transverse velocity was the most reliable measure; variability may be affected by lesion depth. At least five measurements should be reported with LOA to assist future comparability between shear wave elastography systems in evaluating soft tissue masses.

2019 ◽  
Vol 38 (1) ◽  
pp. 37-43 ◽  
Author(s):  
Hyun Jung Yeoh ◽  
Tae-Yoon Kim ◽  
Jeong Ah Ryu

2016 ◽  
Vol 27 (2) ◽  
pp. 723-731 ◽  
Author(s):  
B. Pass ◽  
M. Jafari ◽  
E. Rowbotham ◽  
E. M. A. Hensor ◽  
H. Gupta ◽  
...  

Radiology ◽  
2019 ◽  
Vol 290 (2) ◽  
pp. 410-417 ◽  
Author(s):  
Aniket N. Tavare ◽  
Abdulrahman M. Alfuraih ◽  
Elizabeth M. A. Hensor ◽  
Emmanouil Astrinakis ◽  
Harun Gupta ◽  
...  

Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


2021 ◽  
Vol 11 (1) ◽  
pp. 452
Author(s):  
Long-Jun Ren ◽  
Connie Lok-Kan Cheng ◽  
Christina Zong-Hao Ma ◽  
Yong-Ping Zheng

Muscle hardness and its relationship with different muscle lengths/positions are important for understanding its underlying physiological status, and yet remained unclear. This study aimed to detect the local muscle hardness at different muscle lengths and identify the influence of muscle position on muscle hardness in healthy adults. A total of 26 healthy adults participated in this study. Shear wave elastography (SWE) was used to measure the muscle hardness of the Rectus Femoris (RF), Tibialis Anterior (TA) and Gastrocnemius Medialis (GM). Each muscle was tested at both resting (RST) and mid-range lengthened (MRL) positions. A novel ultrasound probe placing method was introduced, applied, and evaluated in this study. Moderate to excellent intra-/inter-rater reliability (Intraclass Correlation Coefficient, ICC ≥ 0.70) was found for muscle hardness measurements. The muscle hardness significantly increased from the RST to MRL position for all three muscles (p < 0.001). This study found that the muscle hardness increased at its mid-range lengthened position from the resting position. The mid-range lengthened muscle position of TA and GM could also be sensitive enough to reflect the age-related changes in local muscle hardness. This study also highlights the importance of placing the assessed extremities in an appropriate and consistent position when assessing muscle qualities by ultrasonics in clinical practice.


2020 ◽  
Vol 49 (6) ◽  
pp. 869-881 ◽  
Author(s):  
N. Winn ◽  
J. Baldwin ◽  
V. Cassar-Pullicino ◽  
P. Cool ◽  
M. Ockendon ◽  
...  

2020 ◽  
Vol 49 (11) ◽  
pp. 1795-1805 ◽  
Author(s):  
Mesut Ozturk ◽  
Mustafa Bekir Selcuk ◽  
Ahmet Veysel Polat ◽  
Aysu Basak Ozbalci ◽  
Yakup Sancar Baris

Sign in / Sign up

Export Citation Format

Share Document