Development of an element-selective monitoring system for adsorbable organic halogens (AOX) with plasma emission spectrometric detection for quasi-continuous waste-water analysis

2001 ◽  
Vol 371 (5) ◽  
pp. 614-620 ◽  
Author(s):  
Tanja Twiehaus ◽  
Stephan Evers ◽  
Wolfgang Buscher ◽  
Karl Cammann
1995 ◽  
Vol 31 (5-6) ◽  
pp. 443-446 ◽  
Author(s):  
P. G. Gaspard ◽  
J. Schwartzbrod

In the framework of agricultural wastewater reuse, the W.H.O. has defined a parasitological quality for sewage with less than one nematode egg per liter. The purpose of this work is to define an effective method to detect helminth eggs in wastewater. Seven techniques have been applied to waste water analysis, with a comparison of their respective results, varying from 26 to 74 %. Be it in the framework of artificial contamination or on site, the best results were obtained with the diphasic technique perfected at the laboratory including a treatment with antiformine at 8 % + ethylacetate followed by a flotation with zinc sulphate at 55%. The validation in the laboratory of the methods performance on treated wastewater allowed us to show that the yield of the method is significantly independent of the egg concentration as well as giving good homogeneity of results with a concentration of 1 egg/litre.


2010 ◽  
Vol 22 (24) ◽  
pp. 2967-2972 ◽  
Author(s):  
Cláudia O. Cunha ◽  
Rita C. R. Silva ◽  
Célia G. Amorim ◽  
Severino A. Júnior ◽  
Alberto N. Araújo ◽  
...  

2016 ◽  
Author(s):  
Tanvi Karpate ◽  
Muhammed Shameem K. M. ◽  
Rajesh Nayak ◽  
Unnikrishnan V. K. ◽  
Santhosh C.

2012 ◽  
Vol 27 (4) ◽  
pp. 707-713 ◽  
Author(s):  
Jukka Pekka lsoaho ◽  
Suvi Tarkkanen ◽  
Raimo Alen ◽  
Juha Fiskari

Abstract Softwood-based kraft mill bleaching effluents from the initial bleaching stages D0 and E1 (the bleaching sequence being D0E 1D 1 E2D2) were treated by the oxidative Fenton method (H20rFeS04) to decompose organic pollutants contammg adsorbable organic halogens (AOX). Experiments designed using the Taguchi method were applied to predict the process conditions that would result in a cost-effective and adequate removal of AOX. In addition to the composition and concentration of the reagents (H202 and Fe2+), the main process parameters selected were temperature and reaction time, while pH was adj usted to an approximate value of 4 (the volumetric ratio of the mixed effluents D0:E 1 was 3 :2). The results indicated that an AOX removal of about 70% for this mixture ( corresponding to about 50% for the mill) was achieved when the eftluent samples were treated for 60 min at 70°C with H202 and Fe2+ at a concentration of 1 600 mg/1 and 28 mg/1, respectively.


2009 ◽  
Vol 81 (2) ◽  
pp. 178-183 ◽  
Author(s):  
Qing-fu Zeng ◽  
Jie Fu ◽  
Yin-tao Shi ◽  
Dong-sheng Xia ◽  
Hai-liang Zhu

Sign in / Sign up

Export Citation Format

Share Document