Application of superfluid hydrodynamics to nuclear rotation

1973 ◽  
Vol 8 (9) ◽  
pp. 557-562 ◽  
Author(s):  
G. Landi ◽  
F. Matera

The arc spectrum of cæsium was investigated with the object of finding whether any of its lines possessed hyperfine structure, resulting from a nuclear magnetic moment, due to a quantised nuclear spin. The lines belonging to the principal series should, owing to the greater degree of penetration of the electron in the (1 s or 6 1 ) orbit, and the correspondingly greater interaction, show the greatest effect. The lines of the principal series are very easily broadened if the vapour pressure of the metal becomes high, so that great care had to be used in obtaining the spectrum of cæsium at a sufficiently low temperature. The most satisfactory method of excitation was found to be the application by means of external electrodes of a very high frequency alternating current to a tube filled with helium at about 2 mm. pressure containing a small quantity of cæsium. The tube required slight heating to bring out the cæsium lines; without this the helium spectrum was very much stronger than the metallic spectrum. At a very low vapour pressures of cæsium the discharge was blue in colour. Under these conditions the lines of the principal series showed no broadening greater than that due to thermal agitation, but at a slightly higher temperature the colour of the discharge became purple and the lines broadened. The lines belonging to the principal series were found to be very close doublets with very nearly constant frequencies differences. A theory is worked out which explains the origin of these doublets, assuming a nuclear spin of one half quantum; by correlating the difference in the separation of the hyperfine structure doublets in the 1 s — m 2 p 3/2 lines and the 1 s — m 2 p 1/2 lines, it is shown that a ratio of the magnetic to the mechanical moment of the nucleus about twice as great as the corresponding ratio for the electron would account for the observed frequency differences. The spectral notation used throughout is that of Hund. The results are compared with those found for the hyperfine structure of some of the bismuth lines by Back and Goudsmid, and are found to be in satisfactory agreement. A selection principle is found which applies both to the bismuth and the cæsium spectrum.


2020 ◽  
pp. 1-8
Author(s):  
Haruhiko Yoshioka ◽  
Kouki Minami ◽  
Hirokazu Odashima ◽  
Keita Miyakawa ◽  
Kayo Horie ◽  
...  

<b><i>Objective:</i></b> The complexity of chromatin (i.e., irregular geometry and distribution) is one of the important factors considered in the cytological diagnosis of cancer. Fractal analysis with Kirsch edge detection is a known technique to detect irregular geometry and distribution in an image. We examined the outer cutoff value for the box-counting (BC) method for fractal analysis of the complexity of chromatin using Kirsch edge detection. <b><i>Materials:</i></b> The following images were used for the analysis: (1) image of the nucleus for Kirsch edge detection measuring 97 × 122 pix (10.7 × 13.4 μm) with a Feret diameter of chromatin mesh (<i>n</i> = 50) measuring 17.3 ± 1.8 pix (1.9 ± 0.5 μm) and chromatin network distance (<i>n</i> = 50) measuring 4.4 ± 1.6 pix (0.49 ± 0.18 μm), and (2) sample images for Kirsch edge detection with varying diameters (10.4, 15.9, and 18.1 μm) and network width of 0.4 μm. <b><i>Methods:</i></b> Three types of bias that can affect the outcomes of fractal analysis in cytological diagnosis were defined. (1) Nuclear position bias: images of 9 different positions generated by shifting the original position of the nucleus in the middle of a 256 × 256 pix (28.1 μm) square frame in 8 compass directions. (2) Nuclear rotation bias: images of 8 different rotations obtained by rotating the original position of the nucleus in 45° increments (0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°). (3) Nuclear size bias: images of varying size (diameter: 190 pix [10.4 μm], 290 pix [15.9 μm], and 330 pix [18.1 μm]) with the same mesh pattern (network width: 8 pix [0.4 μm]) within a 512 × 512 pix square. Different outer cutoff values for the BC method (256, 128, 64, 32, 16, and 8 pix) were applied for each bias to assess the fractal dimension and to compare the coefficient of variation (CV). <b><i>Results:</i></b> The BC method with the outer cutoff value of 32 pix resulted in the least variation of fractal dimension. Specifically, with the cutoff value of 32 pix, the CV of nuclear position bias, nuclear rotation bias, and nuclear size bias were &#x3c;1% (0.1, 0.4, and 0.3%, respectively), with no significant difference between the position and rotation bias (<i>p</i> = 0.19). Our study suggests that the BC method with the outer cutoff value of 32 pix is suitable for the analysis of the complexity of chromatin with chromatin mesh.


2010 ◽  
Author(s):  
A. Kardan ◽  
H. Miri-Hakimabad ◽  
L. Rafat-Motevalli ◽  
Livius Trache ◽  
Alexei Smirnov ◽  
...  

2014 ◽  
Vol 2014 (7) ◽  
Author(s):  
Shira Chapman ◽  
Carlos Hoyos ◽  
Yaron Oz

2012 ◽  
Vol 25 ◽  
pp. 02025 ◽  
Author(s):  
David Schmoranzer ◽  
Marco La Mantia ◽  
Ladislav Skrbek

Sign in / Sign up

Export Citation Format

Share Document