A heat-transfer model for the rotary kiln: Part II. Development of the cross-section model

1989 ◽  
Vol 20 (3) ◽  
pp. 403-419 ◽  
Author(s):  
P. V. Barr ◽  
J. K. Brimacombe ◽  
A. P. Watkinson
2012 ◽  
Vol 38 (1) ◽  
pp. 89-92
Author(s):  
李健 LI Jian ◽  
乔焱 QIAO Yan ◽  
崔伟 CUI Wei ◽  
董浩然 DONG Haoran ◽  
毕学进 BI Xuejin

2004 ◽  
Vol 127 (3) ◽  
pp. 555-563 ◽  
Author(s):  
Jie Luo ◽  
Albert J. Shih

The explicit finite difference formulation of an inverse heat transfer model to calculate the heat flux generated by induction is developed. The experimentally measured temperature data are used as the input for the inverse heat transfer model. This model is particularly suitable for a workpiece with low cross section Biot number. Induction heating experiments are carried out using a carbon steel rod. The finite difference method and thermocouple temperature measurements are applied to estimate the induction heat flux and workpiece temperature. Compared to measured temperatures, the accuracy and limitation of proposed method is demonstrated. The effect of nonuniform temperature distribution, particularly in the heating region during the induction heating, is studied. Analysis results validate the assumption to use the uniform temperature in a cross section for the inverse heat transfer solution of induction heat flux. Sensitivity to the grid spacing, thermocouple location, and thermophysical properties are also studied.


1989 ◽  
Vol 20 (3) ◽  
pp. 391-402 ◽  
Author(s):  
P. V. Barr ◽  
J. K. Brimacombe ◽  
A. P. Watkinson

2018 ◽  
Vol 1 (1) ◽  
pp. 142-150
Author(s):  
Murat Tunc ◽  
Ayse Nur Esen ◽  
Doruk Sen ◽  
Ahmet Karakas

A theoretical post-dryout heat transfer model is developed for two-phase dispersed flow, one-dimensional vertical pipe in a post-CHF regime. Because of the presence of average droplet diameter lower bound in a two-phase sparse flow. Droplet diameter is also calculated. Obtained results are compared with experimental values. Experimental data is used two-phase flow steam-water in VVER-1200, reactor coolant system, reactor operating pressure is 16.2 MPa. On heater rod surface, dryout was detected as a result of jumping increase of the heater rod surface temperature. Results obtained display lower droplet dimensions than the experimentally obtained values.


2006 ◽  
Author(s):  
Filip Kitanoski ◽  
Wolfgang Puntigam ◽  
Martin Kozek ◽  
Josef Hager

2021 ◽  
Vol 71 ◽  
pp. 104456
Author(s):  
Zhuoran Zhang ◽  
Pratik Krishnan ◽  
Zeren Jiao ◽  
M. Sam Mannan ◽  
Qingsheng Wang

Sign in / Sign up

Export Citation Format

Share Document