Evaluating the output setting of a bin feeder in conveyor systems

1985 ◽  
Vol 21 (2) ◽  
pp. 159-164
Author(s):  
R. V. Mertsalov ◽  
P. A. Belavin ◽  
Yu. A. Turtanov
Keyword(s):  
2014 ◽  
Vol 6 (2) ◽  
pp. 117-135
Author(s):  
Alba María del Carmen González Vega

Abstract In the study of family business there is no concrete data on the number of Mexican companies that are family owned, however in reviewing the Economic Census of the National Institute of Statistics and Geography [INEGI] it can be seen that provided staff busy donot receive a formal economic perception from owners, family and other unpaid worker, so that, by linking the concept of family business and the companies that have reported such staff , this study identifies the behavior of the family business considering the contribution to production by sector and hours worked, as well as by gender, concentration of owners, family and other unpaid workers by sector and firm size (micro, small, medium and large companies). This study provides reference the importance of the family business in Mexico’s economic output, setting a mapping behavior from a quantitative approach. It should be noted that this study is part of a doctoral research project in progress over the family business, which is why , it is important to have a reference of the macro context in which the organization is embedded study, presented at the following inquiry.


2002 ◽  
Vol 82 (3) ◽  
pp. 257-263 ◽  
Author(s):  
Paul A Artho ◽  
Jason G Thyne ◽  
Barry P Warring ◽  
Chris D Willis ◽  
Jean-Michel Brismée ◽  
...  

Abstract Background and Purpose. Physiological effects of therapeutic ultrasound (US) are dependent on the intensity and duration of application. The purpose of this study was to test US machines used in clinical settings for proper calibration of time and power output. Methods. Measurements of power output and timer accuracy were obtained from 83 US units in clinical use. The machines were tested at 4 intensity settings (0.5, 1.0, 1.5, and 2.0 W/cm2) using a continuous waveform and a 1-MHz frequency. The measured intensities were converted to percentages of error and compared with the ±20% standard. Results. Of the machines tested, 32 (39%) were outside the calibration standard for at least one output setting. Of these machines, 15 (18%) were above the +20% standard, and 17 (21%) were below the −20% standard for at least one output setting. Of the 32 machines outside the standard, 26 (31%) were outside the standard for 2 or more settings, and 3 (4%) produced no output at any of the settings. Of the mechanical timers tested, 7 (28%) were outside of the ±10% standard for timer accuracy at the 5-minute interval, and 6 (24%) were outside of the standard at the 10-minute interval. All digital timers tested were within the standard. Discussion and Conclusion. More than one third of machines tested in this study were outside the standard for power output, and approximately one fourth of the mechanical timers were outside the standard. Therefore, further improvements in the accuracy of US machine calibration are needed.


Sign in / Sign up

Export Citation Format

Share Document