Separation and determination of Ni(II), Co(II) and Cu(II) by RP-HPLC with hexadecyltrimethylammonium bromide/n-propanol mobile phases

2000 ◽  
Vol 51 (5-6) ◽  
pp. 277-282 ◽  
Author(s):  
M. J. Barroso ◽  
M. P. San Andrés ◽  
S. Vera
2012 ◽  
Vol 2 (2) ◽  
pp. 364-367 ◽  
Author(s):  
Saida Naik Dheeravath ◽  
◽  
Kasani Ramadevi ◽  
Zilla Saraswathi ◽  
Dheeravath Maniklal ◽  
...  

2019 ◽  
Vol 9 (o3) ◽  
Author(s):  
Imad Tarek Hanoon ◽  
Abed Mohammed Daheir AL-Joubory 2 ◽  
Marwa Mohamed Saied 3

A simple , specific, accurate and precise RP-HPLC method was developed for determination of Irbesartan (IRB) in pharmaceutical dosage forms in tablets products and sachet using symmetry (L 1 ) column at 30°C . The signal was detected at 225 nm. A mobile phase dissolve 0.5 g of buffer potassium phosphate in 100 ml distilled water and adjust pH 2.7 , methanol and acetonitrile at ratio (40 :30 :30 ) . and flow rate 1.2ml/min -1 at pH=7.2 a mobile phase The percent recovery was detected 101 % and the linearity of concentration was 10-50 µg.ml -1 and supported this method by using (FT.I.R.) spectrum method for organic spectrophotometer to prove the chemical structure of this drug and some physical properties . we are obtained the result is identical of other literature . The proposed method was applied successfully for determination of the IRB in tablets products.


2013 ◽  
Vol 33 (10) ◽  
pp. 1125-1129 ◽  
Author(s):  
Lin CHEN ◽  
Xin-xin ZHANG ◽  
Xuan DANG ◽  
Tian-long ZHANG ◽  
Zhen-zhi LI ◽  
...  
Keyword(s):  

1992 ◽  
Vol 57 (1) ◽  
pp. 33-45
Author(s):  
Vladimír Jakuš

A new approach to theoretical evaluation of the Gibbs free energy of solvation was applied for estimation of retention data in high-performance liquid chromatography on reversed phases (RP-HPLC). Simple and improved models of stationary and mobile phases in RP-HPLC were employed. Statistically significant correlations between the calculated and experimental data were obtained for a heterogeneous series of twelve compounds.


1992 ◽  
Vol 57 (8) ◽  
pp. 1632-1638 ◽  
Author(s):  
Věra Tatarkovičová ◽  
Zdeněk Stránský

The procedure for the determination of carbamate pesticides in soil was optimized. The following factors affecting the final results were investigated: extracting solvent, extraction procedure, extract purification procedure, and soil type. Triple extraction with acetone and purification of the extract on a two-stage purification column containing an activated carbon-silica gel 1+1 mixture were found optimal. The extracts after treatment were analyzed by RP-HPLC with UV detection. The method developed allows carbamate pesticides in soil to be determined at concentrations in excess of 30 μg kg-1.


2019 ◽  
Vol 35 (1) ◽  
pp. 140-149 ◽  
Author(s):  
Somana Siva Prasad ◽  
G. V. Krishna Mohan ◽  
A. Naga Babu

In this study, a novel, simple and precise RP-HPLC method has been developed for the quantitative analysis of Lenalidomide (LLM) in pharmaceutical formulations using analytical quality by design approach. An X-bridge-C18 column (150 mm × 4.6 mm × 3.5 µ) with mobile phases containing a Potassium dihydrogen orthophosphate anhydrous buffer and methanol in the ratio of (90:10 v/v) and (35:65 v/v) are used for the estimation of LLM and its degradation products. The flow rate of 0.8 mL/min is maintained and all degradation studies are performed at 210 nm using photodiode array (PDA) detector. Method Validation is carried out according to International Council for Harmonisation (ICH) guidelines and the parameters namely; precision, accuracy, specificity, stability, robustness, linearity, limit of quantitation (LOQ) and limit of detection (LOD) are evaluated. The present developed RP-HPLC method shows the purity angle of peaks is less than their threshold angle, signifying that it to be suitable for stability studies. Hence, the developed method can be used for the successful separation of LLM and its impurities in the pharmaceutical dosage formulations.


Sign in / Sign up

Export Citation Format

Share Document