Comparative evaluation of four different99mTc-sulfur colloid kits used for liver scanning

1991 ◽  
Vol 148 (1) ◽  
pp. 133-143
Author(s):  
Y. F. Shafiq ◽  
M. H. S. Al-Hissoni ◽  
M. A. Abdel-Azeez ◽  
M. H. Jassm ◽  
A. M. Al-Hilli
1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


1986 ◽  
Vol 25 (01) ◽  
pp. 15-18 ◽  
Author(s):  
M. Luostarinen ◽  
M Vorne ◽  
T. Lantto

Summary 99mTc tin colloid accumulated in the lungs in 102 patients during liver imaging both in malignant and benign diseases. The percentage of neoplastic diseases increased when the lung uptake became greater and only patients with malignant final diagnosis had marked lung uptake. Abnormal liver image was seen only in 23%, which disagrees highly with some earlier findings on a rather small number of patients. The cause of increased lung uptake was suggested to be the activation of the reticuloendothelial system (RES) by disease. The activation of the RES was stronger in malignant than in benign diseases. Some type of regional stimulation of the RES was suggested as being due to the location of the disease and both malignant and benign diseases of the chest region stimulated the pulmonary part of the RES more than other parts of the RES.


1997 ◽  
Vol 36 (02) ◽  
pp. 71-75 ◽  
Author(s):  
S. Glatz ◽  
S. N. Reske ◽  
K. G. Grillenberger

Summary Aim: One therapeutic approach to rheumatoid arthritis and other inflammatory arthropathies besides surgical removal of inflamed synovium is radiation synovectomy using beta-emitting radionuclides to destroy the affected synovial tissue. Up to now the major problem associated with the use of labeled particles or colloids has been considerable leakage of radionuclides from the injected joint coupled with high radiation doses to liver and other non target organs. In this study we compared 188Re labeled hydroxyapatite particles and 188Re rhenium sulfur colloid for their potential use in radiation synovectomy. Methods: To this end we varied the labeling conditions (concentrations, pH-value, heating procedure) and analyzed the labeling yield, radiochemical purity, and in vitro stability of the resulting radiopharmaceutical. Results: After optimizing labeling conditions we achieved a labeling yield of more than 80% for 188Re hydroxyapatite and more than 90% for the rhenium sulfur colloid. Both of the radiopharmaceuticals can be prepared under aseptic conditions using an autoclav for heating without loss of activity. In vitro stability studies using various challenge solutions (water, normal saline, diluted synovial fluid) showed that 188Re labeled hydroxyapatite particles lost about 80% of their activity within 5 d in synovial fluid. Rhenium sulfur colloid on the other hand proved to be very stable with a remaining activity of more than 93% after 5 d in diluted synovial fluid. Conclusion: These in vitro results suggest that 188Re labeled rhenium sulfur colloid expects to be more suitable for therapeutic use in radiation synovectomy than the labeled hydroxyapatite particles.


Sign in / Sign up

Export Citation Format

Share Document