Measurement of tissue perfusion by oxygen transport patterns in experimental shock and in high-risk surgical patients

1990 ◽  
Vol 16 (S2) ◽  
pp. S135-S144 ◽  
Author(s):  
W. C. Shoemaker ◽  
P. L. Appel ◽  
H. B. Kram
2011 ◽  
Vol 112 (6) ◽  
pp. 1384-1391 ◽  
Author(s):  
Sanderland T. Gurgel ◽  
Paulo do Nascimento

Critical Care ◽  
2008 ◽  
Vol 12 (S2) ◽  
Author(s):  
JM Silva ◽  
DO Toledo ◽  
A Gulinelli ◽  
FG Correa ◽  
KR Genga ◽  
...  

2012 ◽  
Vol 56 (1) ◽  
pp. 13-14
Author(s):  
Sanderland T. Gurgel ◽  
Paulo do Nascimento

VASA ◽  
2011 ◽  
Vol 40 (2) ◽  
pp. 123-130
Author(s):  
Klein-Weigel ◽  
Richter ◽  
Arendt ◽  
Gerdsen ◽  
Härtwig ◽  
...  

Background: We surveyed the quality of risk stratification politics and monitored the rate of entries to our company-wide protocol for venous thrombembolism (VTE) prophylaxis in order to identify safety concerns. Patients and methods: Audit in 464 medical and surgical patients to evaluate quality of VTE prophylaxis. Results: Patients were classified as low 146 (31 %), medium 101 (22 %), and high risk cases 217 (47 %). Of these 262 (56.5 %) were treated according to their risk status and in accordance with our protocol, while 9 more patients were treated according to their risk status but off-protocol. Overtreatment was identified in 73 (15.7 %), undertreatment in 120 (25,9 %) of all patients. The rate of incorrect prophylaxis was significantly different between the risk categories, with more patients of the high-risk group receiving inadequate medical prophylaxis (data not shown; p = 0.038). Renal function was analyzed in 392 (84.5 %) patients. In those patients with known renal function 26 (6.6 %) received improper medical prophylaxis. If cases were added in whom prophylaxis was started without previous creatinine control, renal function was not correctly taken into account in 49 (10.6 %) of all patients. Moreover, deterioration of renal function was not excluded within one week in 78 patients (16.8 %) and blood count was not re-checked in 45 (9.7 %) of all patients after one week. There were more overtreatments in surgical (n = 53/278) and more undertreatments in medical patients (n = 54/186) (p = 0.04). Surgeons neglected renal function and blood controls significantly more often than medical doctors (p-values for both < 0.05). Conclusions: We found a low adherence with our protocol and substantial over- and undertreatment in VTE prophylaxis. Besides, we identified disregarding of renal function and safety laboratory examinations as additional safety concerns. To identify safety problems associated with medical VTE prophylaxis and “hot spots” quality management-audits proved to be valuable instruments.


2010 ◽  
Vol 58 (S 01) ◽  
Author(s):  
M Müller ◽  
C Heilmann ◽  
S Sorg ◽  
S Kueri ◽  
M Thoma ◽  
...  

2008 ◽  
Vol 108 (5) ◽  
pp. 822-830 ◽  
Author(s):  
Frances Chung ◽  
Balaji Yegneswaran ◽  
Pu Liao ◽  
Sharon A. Chung ◽  
Santhira Vairavanathan ◽  
...  

Background Because of the high prevalence of obstructive sleep apnea (OSA) and its adverse impact on perioperative outcome, a practical screening tool for surgical patients is required. This study was conducted to validate the Berlin questionnaire and the American Society of Anesthesiologists (ASA) checklist in surgical patients and to compare them with the STOP questionnaire. Methods After hospital ethics approval, preoperative patients aged 18 yr or older and without previously diagnosed OSA were recruited. The scores from the Berlin questionnaire, ASA checklist, and STOP questionnaire were evaluated versus the apnea-hypopnea index from in-laboratory polysomnography. The perioperative data were collected through chart review. Results Of 2,467 screened patients, 33, 27, and 28% were respectively classified as being at high risk of OSA by the Berlin questionnaire, ASA checklist, and STOP questionnaire. The performance of the screening tools was evaluated in 177 patients who underwent polysomnography. The sensitivities of the Berlin questionnaire, ASA checklist, and STOP questionnaire were 68.9-87.2, 72.1-87.2, and 65.6-79.5% at different apnea-hypopnea index cutoffs. There was no significant difference between the three screening tools in the predictive parameters. The patients with an apnea-hypopnea index greater than 5 and the patients identified as being at high risk of OSA by the STOP questionnaire or ASA checklist had a significantly increased incidence of postoperative complications. Conclusions Similar to the STOP questionnaire, the Berlin questionnaire and ASA checklist demonstrated a moderately high level of sensitivity for OSA screening. The STOP questionnaire and the ASA checklist were able to identify the patients who were likely to develop postoperative complications.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jean-Luc Fellahi ◽  
Emmanuel Futier ◽  
Camille Vaisse ◽  
Olivier Collange ◽  
Olivier Huet ◽  
...  

AbstractDespite a large body of evidence, the implementation of guidelines on hemodynamic optimization and goal-directed therapy remains limited in daily routine practice. To facilitate/accelerate this implementation, a panel of experts in the field proposes an approach based on six relevant questions/answers that are frequently mentioned by clinicians, using a critical appraisal of the literature and a modified Delphi process. The mean arterial pressure is a major determinant of organ perfusion, so that the authors unanimously recommend not to tolerate absolute values below 65 mmHg during surgery to reduce the risk of postoperative organ dysfunction. Despite well-identified limitations, the authors unanimously propose the use of dynamic indices to rationalize fluid therapy in a large number of patients undergoing non-cardiac surgery, pending the implementation of a “validity criteria checklist” before applying volume expansion. The authors recommend with a good agreement mini- or non-invasive stroke volume/cardiac output monitoring in moderate to high-risk surgical patients to optimize fluid therapy on an individual basis and avoid volume overload. The authors propose to use fluids and vasoconstrictors in combination to achieve optimal blood flow and maintain perfusion pressure above the thresholds considered at risk. Although purchase of disposable sensors and stand-alone monitors will result in additional costs, the authors unanimously acknowledge that there are data strongly suggesting this may be counterbalanced by a sustained reduction in postoperative morbidity and hospital lengths of stay. Beside existing guidelines, knowledge and explicit clinical reasoning tools followed by decision algorithms are mandatory to implement individualized hemodynamic optimization strategies and reduce postoperative morbidity and duration of hospital stay in high-risk surgical patients.


Sign in / Sign up

Export Citation Format

Share Document