Fibrin degradation product D-dimer in the diagnosis of pulmonary embolism

1991 ◽  
Vol 69 (12) ◽  
pp. 522-526 ◽  
Author(s):  
J. Lichey ◽  
I. Reschofski ◽  
T. Dissmann ◽  
M. Priesnitz ◽  
M. Hoffmann ◽  
...  
2019 ◽  
Vol 34 (10) ◽  
pp. 2454-2460 ◽  
Author(s):  
Hong Xu ◽  
Jinwei Xie ◽  
Qiang Huang ◽  
Yiting Lei ◽  
Shaoyun Zhang ◽  
...  

Blood ◽  
1990 ◽  
Vol 76 (7) ◽  
pp. 1341-1348 ◽  
Author(s):  
CM Lawler ◽  
EG Bovill ◽  
DC Stump ◽  
DJ Collen ◽  
KG Mann ◽  
...  

Abstract The validity of markers in plasma of in vitro thrombolysis was investigated in 12 patients with extensive fibrinogen breakdown (greater than 80%, group 1) and in 12 patients with minimal breakdown (less than 20%, group 2). The patients were treated with 100 mg of recombinant tissue-type plasminogen activator (rt-PA) in the “Thrombolysis in Myocardial Infarction II” (TIMI II) trial. Cross- linked fibrin degradation product levels were measured with two variant enzyme-linked immunosorbent assays (ELISAs), both using a fibrin fragment D-dimer specific capture antibody. In one instance, a tag antibody was used that cross-reacts with fibrinogen (pan-specific tag ELISA); in the other, the tag antibody was specific for fibrin fragment D (fibrin-specific tag ELISA). Apparent concentrations of cross-linked fibrin degradation products at baseline were within normal limits with both assays in most patients. At 8 hours after rt-PA infusion, the measured cross-linked fibrin degradation products were increased about twofold to fourfold in group 2 with both assays. However, in group 1, levels were significantly higher with the pan-specific tag ELISA (5.8 +/- 4.2 micrograms/mL) compared with the fibrin-specific tag ELISA (1.5 +/- 1.3 micrograms/mL). This observation was most likely a result of detection of fibrinogen degradation products in the pan-specific ELISA. Apparent levels of fibrinopeptide B beta 1–42, a marker of fragment X formation, increased during thrombolysis from 4.2 +/- 2.8 pmol/mL to 2,000 +/- 230 pmol/mL in group 1 and from 4.1 +/- 2.1 pmol/mL to 300 +/- 43 pmol/mL in group 2, and were correlated significantly with the extent of fibrinogen breakdown (r = -0.8). Fibrinopeptide beta 15–42 levels increased from 4.3 +/- 3 pmol/mL to 70 +/- 19 pmol/mL in group 1, but did not increase in group 2. The apparent increase in group 1 could be explained by cross-reactivity of fibrinopeptide B beta 1–42 in the fibrinopeptide beta 15–42 assay. We conclude that cross-linked fibrin degradation product levels as measured with a pan-specific tag ELISA and fibrinopeptide beta 15–42 levels as measured with certain monoclonal antibody-based ELISA are influenced by the extent of fibrinogen degradation. Fibrinopeptide B beta 1–42 is a marker specific for fibrinogen breakdown. Cross-linked fibrin degradation product levels, measured with a fibrin-specific tag ELISA, appear to be markers specific for thrombolysis. Consequently, assays similar to the fibrin- specific tag ELISA may provide more accurate information when correlated with clinical endpoints.


2014 ◽  
Vol 63 (1) ◽  
pp. 86-89
Author(s):  
Masashi MIYOSHI ◽  
Sadanobu MATSUDA ◽  
Chihiro INOUE ◽  
Norimichi TAKAMATSU ◽  
Toshio DOI

2020 ◽  
Author(s):  
Li Xue ◽  
Ming Li ◽  
Li Tao ◽  
Xueyi Li ◽  
Wei Wang ◽  
...  

Abstract Objective: This study aimed to assess the role of coagulation-related indicators such as plasma fibrinogen (FIB), D-dimer, and fibrin degradation product (FDP) in rheumatoid arthritis (RA) and their association with disease activity.Methods: Data from 105 RA patients and 102 age- and gender- matched healthy controls were collected in the retrospective study. Disease activity score in 28 joints based on C-reactive protein (DAS28-CRP) was used to divide the RA patients into inactive group (DAS28-CRP ≤ 2.7) and active group (DAS28-CRP > 2.7). The association between plasma FIB, D-dimer, and FDP and DAS28-CRP was evaluated by spearman correlation. Receiver operating characteristic (ROC) curve was applied to determine the area under curve (AUC) value. The prognostic value of plasma FIB, D-dimer, and FDP in the RA disease activity was tested by logistical regression analysis.Results: RA patients showed higher FAR levels of plasma FIB, D-dimer, and FDP than the controls (P < 0.01). Plasma FIB, D-dimer, and FDP were also increased in active group of RA patients than those in inactive group (P < 0.001). Spearman analysis showed that plasma FIB, D-dimer, and FDP were positively related with DAS28-CRP (P < 0.001) in RA patients. ROC curve analyses revealed that the AUC of D-dimer was higher than ESR and RF, and that of FDP was higher than RF in RA patients. In addition, the optimal cut-off value of plasma FIB, D-dimer, and FDP for RA diagnosis was 286 mg/dL, 470 μg/L, and 1.45 mg/L, respectively. Logistical regression analyses showed that D-dimer (odds ratio = 2.862, 95% confidence interval: 1.851-4.426, P < 0.001) was a predictor for RA disease activity.Conclusions: FIB, D-dimer, and FDP were increased in RA patients and positively correlated with the disease activity of RA. D-dimer may act as a novel inflammatory parameter for predicting disease activity in RA patients.


1997 ◽  
Vol 77 (02) ◽  
pp. 262-266 ◽  
Author(s):  
M C H Janssen ◽  
A E Heebels ◽  
M de Metz ◽  
H Verbruggen ◽  
H Wollersheim ◽  
...  

SummaryStudies measuring the fibrin degradation product D-Dimer (DD) using enzyme-linked immunosorbent assays (ELISA) in patients with venographically proven deep venous thrombosis (DVT) suggest that it is possible to exclude DVT when DD level is below a certain cut-off level. However, ELISA methods are time-consuming and not available in all laboratories. Different rapid latex-agglutination assays have been investigated, but their sensitivity is considerably lower.In the present study we compared the value of four novel latex DD tests (Tinaquant®, Minutex®, Ortho® and SimpliRed®) and one rapid ELISA (VIDAS®) to a classical ELISA DD assay (Organon Mab Y18®) in 132 patients suspected of DVT.The VIDAS®, a new quantitative automated ELISA, had a sensitivity of 100% and a negative predictive value of 100% for both proximal and distal DVT at a cut-off level of 500 ng/ml. The Tinaquant® assay, a new quantitative latex method, had a sensitivity of 99% and a negative predictive value of 93% for both proximal and distal DVT at a cut-off level of 500 ng/ml. For proximal DVT only, both assays had a sensitivity and negative predictive value of 100%. VIDAS® and Tinaquant® correlated well with ELISA (correlation of r = 0.96 and r = 0.98 respectively). Sensitivities of the semi-quantitative latex assays Minutex®, Ortho® and SimpliRed® were considerably lower (77%, 51 % and 61 % respectively).These results suggest that VIDAS® and Tinaquant® may be used instead of ELISA DD in the exclusion of DVT. Tinaquant® can be performed within 20 min and VIDAS® within 35 min. Both assays might be used as a routine screening test and should be evaluated in large clinical management studies.


Sign in / Sign up

Export Citation Format

Share Document