Experimental-theoretical investigations of the pressure pipeline at the Zagorsk water-storage power plant

1992 ◽  
Vol 26 (8) ◽  
pp. 501-507
Author(s):  
N. V. Khalturina ◽  
M. F. Sarkisova
2019 ◽  
Vol 12 (2) ◽  
Author(s):  
Ahmad Mukhtar ◽  
Omar Qazi M. ◽  
Umar Shafiq ◽  
M. Ahsan Badr Khan

Global survival and human comfort in now a day strongly depend upon energy and environment. In this research generalized thermodynamic model equations were subjected to 4MW rice husk fired thermal power plant in Pakistan for theoretical investigations on work lost and entropy generation to check the plant thermal performance and irreversibility’s and concluded that the entropy generation and work lost is highest in Furnace/Boiler that is 3487.12352 KWK-1 and 1039.685 ×103 respectively. The work lost in Furnace/Boiler is about 32.4641% while the overall efficiency of the power plant is 59.8917%.


Author(s):  
Shinichi Matsuura ◽  
Ichiro Tamura

It is important in the confirmation of the safety of the nuclear power plant to clarify the response behavior of a vertical cylindrical water storage tank under seismic motion. When a vertical cylindrical tank is shaken by a large earthquake, deformation of side shell due to the elephant foot buckling, the oval vibration etc. may occur. The occurrence of those deformations depends on materials, shapes, stored water level and time history of seismic motion. Then, response behavior was obtained for a condensate storage tank (CST) model under large seismic motion such as standard earthquake Ss multiplied by 2 with the elastic-plastic finite element calculation. In this calculation, dynamic water pressure and elastic-plastic characteristics of the material were taken into account. In this case, the elephant foot bulge did not occur but the oval vibration of side shell became dominant. Based on the result, we estimated the structural integrity of the tank.


2016 ◽  
Vol 6 (1) ◽  
pp. 21-26
Author(s):  
Muradulla Mukhammadievich MUKHAMMADIEV ◽  
Boborakhim Urishevich URISHEV ◽  
Kurbon Salikhdzhanovich DZHURAEV ◽  
Jamol Makhmud ugli MAHMUDOV

The technique of determining the basic parameters of the new water-lifting devices used in the composition of the pumped storage power plant of small capacity. Show the results of calculations by this technique for a pumped storage power plant of 10 kW. The results of calculations of the jet device and air-lift installation designed to work in PSP, showed the suitability of the proposed methodology that can be used in the design of hydropower facilities operating with a water-lifting devices using the energy of interaction between water and compressed air.


1992 ◽  
Vol 26 (8) ◽  
pp. 484-491
Author(s):  
A. A. Bykadorov ◽  
T. V. Busygina
Keyword(s):  

1992 ◽  
Vol 26 (8) ◽  
pp. 481-483
Author(s):  
L. B. L'vovich ◽  
M. I. Pertsovskii
Keyword(s):  