Release of fission products from the reactor fuel of the bilibinsk nuclear power plant under conditions which simulate a severe accident

Atomic Energy ◽  
1993 ◽  
Vol 74 (5) ◽  
pp. 380-384 ◽  
Author(s):  
Yu. D. Baranaev ◽  
A. N. Viktorov ◽  
V. V. Dolgov ◽  
L. I. Moseev
2012 ◽  
Vol 2012 ◽  
pp. 1-11 ◽  
Author(s):  
Gilberto Espinosa-Paredes ◽  
Raúl Camargo-Camargo ◽  
Alejandro Nuñez-Carrera

The loss-of-coolant accident (LOCA) simulation in the boiling water reactor (BWR) of Laguna Verde Nuclear Power Plant (LVNPP) at 105% of rated power is analyzed in this work. The LVNPP model was developed using RELAP/SCDAPSIM code. The lack of cooling water after the LOCA gets to the LVNPP to melting of the core that exceeds the design basis of the nuclear power plant (NPP) sufficiently to cause failure of structures, materials, and systems that are needed to ensure proper cooling of the reactor core by normal means. Faced with a severe accident, the first response is to maintain the reactor core cooling by any means available, but in order to carry out such an attempt is necessary to understand fully the progression of core damage, since such action has effects that may be decisive in accident progression. The simulation considers a LOCA in the recirculation loop of the reactor with and without cooling water injection. During the progression of core damage, we analyze the cooling water injection at different times and the results show that there are significant differences in the level of core damage and hydrogen production, among other variables analyzed such as maximum surface temperature, fission products released, and debris bed height.


Author(s):  
G. Adlys ◽  
D. Adlienė

Lithuania has to solve a lot of problems when closing Ignalina nuclear power plant (INPP). One of them is predicting, monitoring and managing of radiation situation and its impact to environment during this period. Calculated data files for nuclides in nuclear fuel could be used for this aim.This work presents our calculations of concentrations and activities of actinides and fission products in RBMK-1500 reactor fuel in dependence on fuel burn up and cooling time.Calculations were made using French computer code Apollo1 [1].


Author(s):  
Tatiana Grebennikova ◽  
Abbie N Jones ◽  
Clint Alan Sharrad

Irradiated graphite waste management is one of the major challenges of nuclear power-plant decommissioning throughout the world and significantly in the UK, France and Russia where over 85 reactors employed...


2018 ◽  
Vol 4 (3) ◽  
Author(s):  
Kevin Fernández-Cosials ◽  
Gonzalo Jiménez ◽  
César Serrano ◽  
Luisa Ibáñez ◽  
Ángel Peinado

During a severe accident (SA) in a nuclear power plant (NPP), there are several challenges that need to be faced. To coup with a containment overpressure, the venting action will lower the pressure but it will release radioactivity to the environment. In order to reduce the radioactivity released, a filtered containment venting system (FCVS) can be used to retain iodine and aerosols radioactive releases coming from the containment atmosphere. However, during a SA, large quantities of hydrogen can also be generated. Hydrogen reacts violently with oxygen and its combustion could impair systems, components, or structures. For this reason, to protect the integrity of the FCVS against hydrogen explosions, an inertization system is found necessary. This system should create an inert atmosphere previous to any containment venting that impedes the contact of hydrogen and oxygen. In this paper, the inertization system for Cofrentes NPP is presented. It consists of a nitrogen injection located in three different points. A computational model of the FCVS as well as the inertization system has been created. The results show that if the nitrogen sweeps and the containment venting are properly synchronized, the hydrogen risk could be reduced to a minimum and therefore, the integrity of the FCVS would be preserved.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Kwame Gyamfi ◽  
Sylvester Attakorah Birikorang ◽  
Emmanuel Ampomah-Amoako ◽  
John Justice Fletcher

Abstract Atmospheric dispersion modeling and radiation dose calculation have been performed for a generic 1000 MW water-water energy reactor (VVER-1000) assuming a hypothetical loss of coolant accident (LOCA). Atmospheric dispersion code, International Radiological Assessment System (InterRAS), was employed to estimate the radiological consequences of a severe accident at a proposed nuclear power plant (NPP) site. The total effective dose equivalent (TEDE) and the ground deposition were calculated for various atmospheric stability classes, A to F, with the site-specific averaged meteorological conditions. From the analysis, 3.7×10−1 Sv was estimated as the maximum TEDE corresponding to a downwind distance of 0.1 km within the dominating atmospheric stability class (class A) of the proposed site. The intervention distance for evacuation (50 mSv) and sheltering (10 mSv) were estimated for different stability classes at different distances. The intervention area for evacuation ended at 0.5 km and that for sheltering at 1.5 km. The results from the study show that designated area for public occupancy will not be affected since the estimated doses were below the annual regulatory limits of 1 mSv.


Author(s):  
Frank Kretzschmar

In the case of a severe accident in a nuclear power plant there is a residual risk, that the Reactor Pressure Vessel (RPV) does not withstand the thermal attack of the molten core material, of which the temperature can be about 3000 K. For the analysis of the processes governing melt dispersal and heating up of the containment atmosphere of a nuclear power plant in the case of such an event, it is important to know the time of the onset of gas blowthrough during the melt expulsion through the hole in the bottom of the RPV. In the test facility DISCO-C (Dispersion of Simulant Corium-Cold) at the FZK /6/, experiments were performed to furnish data for modeling Direct Containment Heating (DCH) processes in computer codes that will be used to extrapolate these results to the reactor case. DISCO-C models the RPV, the Reactor Coolant System (RCS), cavity and the annular subcompartments of a large European reactor in a scale 1:18. The liquid type, the initial liquid mass, the type of the driving gas and the size of the hole were varied in these experiments. We present results for the onset of the gas blowthrough that were reached by numerical analysis with the Multiphase-Code SIMMER. We compare the results with the experimental results from the DISCO-C experiments and with analytical correlations, given by other authors.


Sign in / Sign up

Export Citation Format

Share Document