High-precision test installation for measuring attenuations at 0.01?100 MHz

1979 ◽  
Vol 22 (10) ◽  
pp. 1259-1261
Author(s):  
V. I. Aderikhin ◽  
V. P. Bekkerov
1981 ◽  
Vol 24 (2) ◽  
pp. 99-101
Author(s):  
M. Andrusenko ◽  
V. P. Danil'chenko ◽  
V. S. Kupko ◽  
S. M. Kochin ◽  
I. V. Lukin ◽  
...  

2014 ◽  
Vol 113 (19) ◽  
Author(s):  
Yonggun Jun ◽  
Momčilo Gavrilov ◽  
John Bechhoefer

1983 ◽  
Vol 51 (12) ◽  
pp. 1109-1109 ◽  
Author(s):  
Jaw-Shen Tsai ◽  
A. K. Jain ◽  
J. E. Lukens

2014 ◽  
Vol 613 ◽  
pp. 381-391
Author(s):  
Daniel Hagedorn ◽  
Heinz Peter Heyne ◽  
Stephan Metschke ◽  
Uwe Langner ◽  
Vincent Lebat ◽  
...  

The MICROSCOPE (MicroSatellite à traînée Compensée pour l'Observation du Principe d'Equivalence) project is an orbit-based mission to verify the Weak Equivalent Principle with an uncertainty of 10-15. To achieve this goal two differential accelerometer, each equipped with two high precision test masses (made of PtRh10 and TiAl6V4 in the form of hollow cylinders with four flats at the outer shell and six precision countersinks at each face), are to be launched in Spring 2016 and shall orbit the earth for approx. one and a half year.


2019 ◽  
Vol 4 (2) ◽  
pp. 45 ◽  
Author(s):  
Kristian Piscicchia ◽  
Aidin Amirkhani ◽  
Sergio Bartalucci ◽  
Sergio Bertolucci ◽  
Massimiliano Bazzi ◽  
...  

The VIP-2 experiment aims to perform high precision tests of the Pauli Exclusion Principle for electrons. The method consists in circulating a continuous current in a copper strip, searching for the X radiation emission due to a prohibited transition (from the 2p level to the 1s level of copper when this is already occupied by two electrons). VIP already set the best limit on the PEP violation probability for electrons 1 2 β 2 < 4.7 × 10 − 29 , the goal of the upgraded VIP-2 (VIolation of the Pauli Exclusion Principle-2) experiment is to improve this result of two orders of magnitude at least. The experimental apparatus and the results of the analysis of a first set of collected data will be presented.


2012 ◽  
Vol 542-543 ◽  
pp. 667-670 ◽  
Author(s):  
Wei He

This paper has adopted photoelectric conversion technology and computer application tech-nology , together with the Microsoft Visual C++6.0 software, developed a test system that consists of software and hardware, which involved the precision test and movement parameter calculating of the roller gear cam indexing driven. Experiments proved that the reliability and testing precision of this system are preferable.


Sign in / Sign up

Export Citation Format

Share Document