Experimental investigations of a chemotron fluid flow rate meter

1975 ◽  
Vol 18 (6) ◽  
pp. 838-840
Author(s):  
I. K. Fomin
2008 ◽  
Vol 130 (2) ◽  
Author(s):  
Jianhua Fan ◽  
Simon Furbo

Theoretical and experimental investigations of the flow and temperature distribution in a 12.53m2 solar collector panel with an absorber consisting of two vertical manifolds interconnected by 16 parallel horizontal fins have been carried out. The investigations are focused on overheating and boiling problems in the collector panel. Single-phase liquid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics (CFD) calculations. Differently designed collectors are investigated with different collector fluid volume flow rates. The effect of friction and the influence of the buoyancy effects are considered in the investigations. Further, experimental investigations of the solar collector panel are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the back of the absorber tubes. The measured temperatures are compared to the temperatures determined by the CFD model and there is a good agreement between the measured and calculated temperatures. Calculations with the CFD model elucidate the flow and temperature distribution in the collector. The influences of collector fluid flow rate and inlet temperature on the flow and temperature distribution are shown. The flow distribution through the absorber tubes is uniform if a high flow rate of 10.0l∕min is used. By decreased collector fluid flow rate and by increased collector fluid inlet temperature, the flow distribution gets less uniform due to the influence of buoyancy force. If the collector fluid flow rate is small and the collector fluid inlet temperature is high enough, severe nonuniform flow distribution may happen with a small flow rate or even zero or reverse flow in the upper horizontal strips, resulting in overheating or boiling problems in the strips. The CFD calculations elucidate the flow and temperature distribution in the collector panels of different designs. Based on the investigations, recommendations are given in order to avoid overheating or boiling problems in the solar collector panel.


2019 ◽  
Vol 11 (1) ◽  
pp. 01025-1-01025-5 ◽  
Author(s):  
N. A. Borodulya ◽  
◽  
R. O. Rezaev ◽  
S. G. Chistyakov ◽  
E. I. Smirnova ◽  
...  

1956 ◽  
Vol 23 (2) ◽  
pp. 269-272
Author(s):  
L. F. Welanetz

Abstract An analysis is made of the suction holding power of a device in which a fluid flows radially outward from a central hole between two parallel circular plates. The holding power and the fluid flow rate are determined as functions of the plate separation. The effect of changing the proportions of the device is investigated. Experiments were made to check the analysis.


2018 ◽  
Vol 12 (4) ◽  
pp. 294-300 ◽  
Author(s):  
Santhosh K. Venkata ◽  
Bhagya R. Navada

Abstract In this paper, implementation of soft sensing technique for measurement of fluid flow rate is reported. The objective of the paper is to design an estimator to physically measure the flow in pipe by analysing the vibration on the walls of the pipe. Commonly used head type flow meter causes obstruction to the flow and measurement would depend on the placement of these sensors. In the proposed technique vibration sensor is bonded on the pipe of liquid flow. It is observed that vibration in the pipe varies with the control action of stem. Single axis accelerometer is used to acquire vibration signal from pipe, signal is passed from the sensor to the system for processing. Basic techniques like filtering, amplification, and Fourier transform are used to process the signal. The obtained transform is trained using neural network algorithm to estimate the fluid flow rate. Artificial neural network is designed using back propagation with artificial bee colony algorithm. Designed estimator after being incorporated in practical setup is subjected to test and the result obtained shows successful estimation of flow rate with the root mean square percentage error of 0.667.


2021 ◽  
pp. 1-10
Author(s):  
Yongsheng Liu ◽  
Xing Qin ◽  
Yuchen Sun ◽  
Zijun Dou ◽  
Jiansong Zhang ◽  
...  

Abstract Aiming at the oscillation drag reduction tool that improves the extension limit of coiled tubing downhole operations, the fluid hammer equation of the oscillation drag reducer is established based on the fluid hammer effect. The fluid hammer equation is solved by the asymptotic method, and the distribution of fluid pressure and flow velocity in coiled tubing with oscillation drag reducers is obtained. At the same time, the axial force and radial force of the coiled tubing caused by the fluid hammer oscillator are calculated according to the momentum theorem. The radial force will change the normal contact force of the coiled tubing which has a great influence on frictional drag. The results show that the fluid flow rate and pressure decrease stepwise from the oscillator position to the wellhead position, and the fluid flow rate and pressure will change abruptly during each valve opening and closing time. When the fluid passes through the oscillator, the unit mass fluid will generate an instantaneous axial tension due to the change in the fluid velocity, thereby converting the static friction into dynamic friction, which is conducive to the extend limit of coiled tubing.


Author(s):  
Olutosin Olufisayo Ilori ◽  
Dare A. Adetan ◽  
Lasisi E. Umoru

The study determined the effect of cutting parameters on the surface residual stress of face-milled pearlitic ductile iron with a view to enhancing surface integrity of machined parts in the manufacturing industries. The pearlitic ductile iron used for this study was prepared and four cutting parameters were considered. The results obtained showed that the average surface residual stress of the machined surfaces was tensile and increased significantly with increase in depth of cut. Feed rate and cutting speed exhibited some effect, though not statistically significant, on average surface residual stress. The average residual stress was found to decrease significantly and drastically from 605.39 MPa to 101.72 MPa as cutting fluid flow rate increased from 0 ?/min to 4 ?/min. The study concluded that out of all four cutting parameters investigated, the cutting fluid flow rate has most considerable influence on the surface residual stress of the machined pearlitic ductile iron.


Water ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 841 ◽  
Author(s):  
Reza Taherdangkoo ◽  
Alexandru Tatomir ◽  
Mohammad Taherdangkoo ◽  
Pengxiang Qiu ◽  
Martin Sauter

Hydraulic fracturing of horizontal wells is an essential technology for the exploitation of unconventional resources, but led to environmental concerns. Fracturing fluid upward migration from deep gas reservoirs along abandoned wells may pose contamination threats to shallow groundwater. This study describes the novel application of a nonlinear autoregressive (NAR) neural network to estimate fracturing fluid flow rate to shallow aquifers in the presence of an abandoned well. The NAR network is trained using the Levenberg–Marquardt (LM) and Bayesian Regularization (BR) algorithms and the results were compared to identify the optimal network architecture. For NAR-LM model, the coefficient of determination (R2) between measured and predicted values is 0.923 and the mean squared error (MSE) is 4.2 × 10−4, and the values of R2 = 0.944 and MSE = 2.4 × 10−4 were obtained for the NAR-BR model. The results indicate the robustness and compatibility of NAR-LM and NAR-BR models in predicting fracturing fluid flow rate to shallow aquifers. This study shows that NAR neural networks can be useful and hold considerable potential for assessing the groundwater impacts of unconventional gas development.


Lab on a Chip ◽  
2019 ◽  
Vol 19 (8) ◽  
pp. 1378-1385 ◽  
Author(s):  
Dariush Ashtiani ◽  
Alex de Marco ◽  
Adrian Neild

Surface acoustic wave (SAW) atomisation is investigated in the context of cryo electron microscopy grid preparation. Here, the primary requirements are a reproducible and narrow plume of droplets delivering a low fluid flow rate.


Sign in / Sign up

Export Citation Format

Share Document