Shape, strength, and abrasive power of grains of refractory compound powders

1971 ◽  
Vol 10 (5) ◽  
pp. 397-400
Author(s):  
A. I. Bezykornov ◽  
N. I. Bogomolov ◽  
I. I. Gurinchuk ◽  
M. S. Koval'chenko ◽  
E. S. Konovalova ◽  
...  
1968 ◽  
Vol 7 (3) ◽  
pp. 189-192
Author(s):  
G. V. Samsonov ◽  
V. V. Stasovskaya ◽  
V. K. Kazakov

1949 ◽  
Vol 22 (1) ◽  
pp. 259-262
Author(s):  
J. F. Morley

Abstract These experiments indicate that softeners can influence abrasion resistance, as measured by laboratory machines, in some manner other than by altering the stress-strain properties of the rubber. One possible explanation is that the softener acts as a lubricant to the abrasive surface. Since this surface, in laboratory abrasion-testing machines, is relatively small, and comes repeatedly into contact with the rubber under test, it seems possible that it may become coated with a thin layer of softener that reduces its abrasive power. It would be interesting in this connection to try an abrasive machine in which a long continuous strip of abrasive material was used, no part of it being used more than once, so as to eliminate or minimize this lubricating effect. The fact that the effect of the softener is more pronounced on the du Pont than on the Akron-Croydon machine lends support to the lubrication hypothesis, because on the former machine the rate of wear per unit area of abrasive is much greater. Thus in the present tests the volume of rubber abraded per hr. per sq. cm. of abrasive surface ranges from 0.03 to 0.11 cc. on the du Pont machine and from 0.0035 to 0.0045 cc. on the Akron-Croydon machine. On the other hand, if the softener acts as a lubricant, it would be expected to reduce considerably the friction between the abrasive and the rubber and hence the energy used in dragging the rubber over the abrasive surface. The energy figures given in the right-hand columns of Tables 1 and 3, however, show that there is relatively little variation between the different rubbers. As a test of the lubrication hypothesis, it would be of interest to vary the conditions of test so that approximately the same amount of rubber per unit area of abrasive is abraded in a given time on both machines; this should show whether the phenomena observed under the present test conditions are due solely to the difference in rate of wear or to an inherent difference in the type of wear on the two machines. This could most conveniently be done by considerably reducing the load on the du Pont machine. In the original work on this machine the load was standardized at 8 pounds, but no figures are quoted to show how abrasion loss varies with the load. As an addition to the present investigation, it is proposed to examine the effect of this variation with special reference to rubbers containing various amounts and types of softener. Published data on the influence of softeners on the road wear of tire rubbers do not indicate anything like such large effects as are shown by the du Pont machine. This throws some doubt on the value of this machine for testing tire tread rubbers, a conclusion which is confirmed by information obtained from other workers.


1975 ◽  
Vol 14 (3) ◽  
pp. 188-192
Author(s):  
A. E. Gorbunov ◽  
Yu. A. Otradinskii ◽  
V. S. Matveeva ◽  
F. G. Sevost'yanova
Keyword(s):  

2016 ◽  
Vol 87 (3) ◽  
pp. 455-459 ◽  
Author(s):  
Roberta Lione ◽  
Francesca Gazzani ◽  
Chiara Pavoni ◽  
Stefano Guarino ◽  
Vincenzo Tagliaferri ◽  
...  

ABSTRACT Objective: To test in vitro and in vivo the wear performance of diamond-coated strips by means of tribological testing and scanning electronic microscope (SEM). Materials and Methods: To evaluate the in vitro wear performance, a tribological test was performed by a standard tribometer. The abrasive strips slid against stationary, freshly extracted premolars fixed in resin blocks, at a 2-newton load. At the end of the tribological test, the residual surface of the strip was observed by means of SEM analysis, which was performed every 50 meters until reaching 300 meters. For the in vivo analysis, the strip was used for 300 seconds, corresponding to 250 meters. Results: The strips presented a fenestrated structure characterized by diamond granules alternating with voids. After the first 50 meters, it was possible to observe tooth material deposited on the surface of the strips and a certain number of abrasive grains detached. The surface of the strip after 250 meters appeared smoother and therefore less effective in its abrasive power. After 300 seconds of in vivo utilization of the strip, it was possible to observe the detachment of diamond abrasive grains, the near absence of the grains and, therefore, loss of abrasive power. Conclusions: Under ideal conditions, after 5 minutes (300 meters) of use, the strip loses its abrasive capacity by about 60%. In vivo, a more rapid loss of abrasive power was observed due to the greater load applied by the clinician in forcing the strip into the contact point.


Refractories ◽  
1977 ◽  
Vol 18 (7-8) ◽  
pp. 467-469
Author(s):  
V. A. Kostrov ◽  
V. I. Solodkov

2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
O. Sotelo-Mazón ◽  
C. Cuevas-Arteaga ◽  
J. Porcayo-Calderón ◽  
V.M. Salinas Bravo ◽  
G. Izquierdo-Montalvo

Corrosion resistance of pure Fe, Cr, and Ni materials exposed in NaVO3molten salt at 700°C was evaluated in static air during 100 hours. The corrosion resistance was determined using potentiodynamic polarization, open circuit potential, and lineal polarization resistance. The conventional weight loss method (WLM) was also used during 100 hours. The electrochemical results showed that Fe and Cr have a poor corrosion resistance, whereas pure Ni showed the best corrosion performance, which was supported by the passive layer of NiO formed on the metallic surface and the formation of Ni3V2O8during the corrosion processes, which is a refractory compound with a higher melting point than that of NaVO3, which reduces the corrosivity of the molten salt. Also, the behavior of these materials was associated with the way in which their corresponding oxides were dissolved together with their type of corrosion attack. Through this study, it was confirmed that when materials suffer corrosion by a localized processes such as pitting, the WLM is not reliable, since a certain amount of corrosion products can be kept inside the pits. The corroded samples were analyzed through scanning electron microscopy.


1976 ◽  
Vol 15 (1) ◽  
pp. 34-39
Author(s):  
P. S. Kislyi ◽  
M. A. Kuzenkova ◽  
L. I. Struk ◽  
S. A. Shvab ◽  
M. S. Borovikova

Sign in / Sign up

Export Citation Format

Share Document