Differential pulse polarographic determination of trace levels of iron(III) by using the catalytic current

1994 ◽  
Vol 349 (6) ◽  
pp. 477-478 ◽  
Author(s):  
Bharathibai J. Basu ◽  
D. K. Padma ◽  
S. R. Rajagopalan
1982 ◽  
Vol 47 (8) ◽  
pp. 2214-2218 ◽  
Author(s):  
Věra Stará ◽  
Miloslav Kopanica

The measurement of the catalytic current, caused by the interaction between cyanide and nickel(II)-ethanolamine complex enables the determination with the detection limit 0.4 μg l-1 with the relative mean deviation 0.90%. Direct fast pulse polarographic determination, based on the measurement of the anodic current has the limit 40 μg l-1 and the relative mean deviation 0.93%.


1983 ◽  
Vol 48 (10) ◽  
pp. 2903-2908 ◽  
Author(s):  
Viktor Vrabec ◽  
Oldřich Vrána ◽  
Vladimír Kleinwächter

A method is described for determining total platinum content in urine, blood plasma and tissues of patients or experimental animals receiving cis-dichlorodiamineplatinum(II). The method is based on drying and combustion of the biological material in a muffle furnace. The product of the combustion is dissolved successively in aqua regia, hydrochloric acid and ethylenediamine. The resulting platinum-ethylenediamine complex yields a catalytic current at a dropping mercury electrode allowing to determine platinum by differential pulse polarography. Platinum levels of c. 50-1 000 ng per ml of the biological fluid or per 0.5 g of a tissue can readily be analyzed with a linear calibration.


1985 ◽  
Vol 10 (2) ◽  
pp. 177-183
Author(s):  
A. D. Woolfson ◽  
D. F. McCafferty ◽  
S. P. Gorman ◽  
Lesley Anderson

Author(s):  
M. Nogami Eurica ◽  
M. Dalmeida Gracinda ◽  
Jorge Nozaki

Differential pulse polarography was employed for the determination of arsenic in bituminous coal from Figueiras, Parana, Brazil. The dried coal sample was crushed to -100 mesh, ashed, and treated with reducing reagents in acidic media. The arsine generated was collected and selectively oxidized to Al +3 using an absorbing solution of 0.1 mol.L -1 [tris(hydroxymethyl) aminomethane] ( TRIS) and 0. 002 mol.L -1 silver nitrate. A solution of TRIS and hydrochloric acid, pH -1, was used as supporting electrolyte for differential pulse polarographic determination of Al+3 in the concentration range 0.05 -0.60 μglmL. The average arsenic concentration found was 69.0 ± 2.6 mg.kg -1 and was in agreement with the spectrophotometric method using silver-diethyldithiocarbamate-pyridine.


Talanta ◽  
1997 ◽  
Vol 44 (10) ◽  
pp. 1859-1863 ◽  
Author(s):  
N SREEDHAR ◽  
P RAJENDRAKUMARREDDY ◽  
G SUBBAREDDY ◽  
S REDDY

Sign in / Sign up

Export Citation Format

Share Document