Electron probe X-ray microanalysis as a non-destructive method for the quantitative determination of ion-implanted impurities in silicon

1991 ◽  
Vol 341 (10) ◽  
pp. 601-605 ◽  
Author(s):  
A. P. Alexeyev ◽  
V. I. Zaporozchenko
1986 ◽  
Vol 141 (1) ◽  
pp. 69-78 ◽  
Author(s):  
Gregory R. Hook ◽  
Ronald J. Elin ◽  
Jeanette M. Hosseini ◽  
Carol Swyt ◽  
Charles E. Fiori

2006 ◽  
Vol 21 (2) ◽  
pp. 140-144 ◽  
Author(s):  
Chul-Un Ro

An electron probe X-ray microanalysis (EPMA) technique using an energy-dispersive X-ray detector with an ultrathin window, designated low-Z particle EPM, has been developed. The low-Z particle EPMA allows the quantitative determination of concentrations of low-Z elements, such as C, N, and O, as well as higher-Z elements that can be analyzed by conventional energy-dispersive EPMA. The quantitative determination of low-Z elements (using full Monte Carlo simulations, from the electron impact to the X-ray detection) in individual environmental particles has improved the applicability of single-particle analysis, especially in atmospheric environmental aerosol research; many environmentally important atmospheric particles, e.g. sulfates, nitrates, ammonium, and carbonaceous particles, contain low-Z elements. The low-Z particle EPMA was applied to characterize loess soil particle samples of which the chemical compositions are well defined by the use of various bulk analytical methods. Chemical compositions of the loess samples obtained from the low-Z particle EPMA turn out to be close to those from bulk analyses. In addition, it is demonstrated that the technique can also be used to assess the heterogeneity of individual particles.


Author(s):  
A. LeFurgey ◽  
P. Ingram ◽  
L.J. Mandel

For quantitative determination of subcellular Ca distribution by electron probe x-ray microanalysis, decreasing (and/or eliminating) the K content of the cell maximizes the ability to accurately separate the overlapping K Kß and Ca Kα peaks in the x-ray spectra. For example, rubidium has been effectively substituted for potassium in smooth muscle cells, thus giving an improvement in calcium measurements. Ouabain, a cardiac glycoside widely used in experimental and clinical applications, inhibits Na-K ATPase at the cell membrane and thus alters the cytoplasmic ion (Na,K) content of target cells. In epithelial cells primarily involved in active transport, such as the proximal tubule of the rabbit kidney, ouabain rapidly (t1/2= 2 mins) causes a decrease2 in intracellular K, but does not change intracellular total or free Ca for up to 30 mins. In the present study we have taken advantage of this effect of ouabain to determine the mitochondrial and cytoplasmic Ca content in freeze-dried cryosections of kidney proximal tubule by electron probe x-ray microanalysis.


1983 ◽  
Vol 27 ◽  
Author(s):  
L. Salamanca-Riba ◽  
B.S. Elman ◽  
M.S. Dresselhaus ◽  
T. Venkatesan

ABSTRACTRutherford backscattering spectrometry (RBS) is used to characterize the stoichiometry of graphite intercalation compounds (GIC). Specific application is made to several stages of different donor and acceptor compounds and to commensurate and incommensurate intercalants. A deviation from the theoretical stoichiometry is measured for most of the compounds using this non-destructive method. Within experimental error, the RBS results agree with those obtained from analysis of the (00ℓ) x-ray diffractograms and weight uptake measurements on the same samples.


1972 ◽  
Vol 9 (1) ◽  
pp. 36-42 ◽  
Author(s):  
Calvert C. Bristol

X-ray powder diffraction methods, successful in quantitative determination of silicate minerals in fine-grained rocks, have been applied to the determination of calcite, dolomite, and magnesite in greenschist facies meta-volcanic rocks. Internal standard graphs employing two standards (NaCl and Mo) have been determined.Carbonate mineral modes (calcite and dolomite) for 6 greenschist facies meta-volcanic rocks obtained by the X-ray powder method have been compared to normative carbonate mineral contents calculated for the same rocks. This comparison showed a maximum variation of 7.7 wt.% between the X-ray modes and the normative carbonate mineral contents of the rocks. Maximum standard deviation for the X-ray modes of these rocks was equivalent to 4.4 wt.%.