scholarly journals OC18.02: Inter-observer agreement on cardiac defects using spatio temporal image correlation and volume computer aided diagnosis

2009 ◽  
Vol 34 (S1) ◽  
pp. 34-34
Author(s):  
J. Bello-Muñoz ◽  
E. Carreras ◽  
D. C. Albert ◽  
Q. Ferrer ◽  
A. Esquivel ◽  
...  
2018 ◽  
Vol 5 (3) ◽  
pp. 62 ◽  
Author(s):  
Karem Marcomini ◽  
Eduardo Fleury ◽  
Vilmar Oliveira ◽  
Antonio Carneiro ◽  
Homero Schiabel ◽  
...  

Purpose: Evaluation of the performance of a computer-aided diagnosis (CAD) system based on the quantified color distribution in strain elastography imaging to evaluate the malignancy of breast tumors. Methods: The database consisted of 31 malignant and 52 benign lesions. A radiologist who was blinded to the diagnosis performed the visual analysis of the lesions. After six months with no eye contact on the breast images, the same radiologist and other two radiologists manually drew the contour of the lesions in B-mode ultrasound, which was masked in the elastography image. In order to measure the amount of hard tissue in a lesion, we developed a CAD system able to identify the amount of hard tissue, represented by red color, and quantify its predominance in a lesion, allowing classification as soft, intermediate, or hard. The data obtained with the CAD system were compared with the visual analysis. We calculated the sensitivity, specificity, and area under the curve (AUC) for the classification using the CAD system from the manual delineation of the contour by each radiologist. Results: The performance of the CAD system for the most experienced radiologist achieved sensitivity of 70.97%, specificity of 88.46%, and AUC of 0.853. The system presented better performance compared with his visual diagnosis, whose sensitivity, specificity, and AUC were 61.29%, 88.46%, and 0.829, respectively. The system obtained sensitivity, specificity, and AUC of 67.70%, 84.60%, and 0.783, respectively, for images segmented by Radiologist 2, and 51.60%, 92.30%, and 0.771, respectively, for those segmented by the Resident. The intra-class correlation coefficient was 0.748. The inter-observer agreement of the CAD system with the different contours was good in all comparisons. Conclusions: The proposed CAD system can improve the radiologist performance for classifying breast masses, with excellent inter-observer agreement. It could be a promising tool for clinical use.


1972 ◽  
Vol 11 (01) ◽  
pp. 32-37 ◽  
Author(s):  
F. T. DE DOMBAL ◽  
J. C. HORROCKS ◽  
J. R. STANILAND ◽  
P. J. GUILLOU

This paper describes a series of 10,500 attempts at »pattern-recognition« by two groups of humans and a computer based system. There was little difference between the performances of 11 clinicians and 11 other persons of comparable intellectual capability. Both groups’ performances were related to the pattern-size, the accuracy diminishing rapidly as the patterns grew larger. By contrast the computer system increased its accuracy as the patterns increased in size.It is suggested (a) that clinicians are very little better than others at pattem-recognition, (b) that the clinician is incapable of analysing on a probabilistic basis the data he collects during a traditional clinical interview and examination and (c) that the study emphasises once again a major difference between human and computer performance. The implications as - regards human- and computer-aided diagnosis are discussed.


2019 ◽  
Author(s):  
S Kashin ◽  
R Kuvaev ◽  
E Kraynova ◽  
H Edelsbrunner ◽  
O Dunaeva ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document