High impact poly(lactic acid)/poly(ethylene octene) blends prepared by reactive blending

2012 ◽  
Vol 53 (2) ◽  
pp. 389-396 ◽  
Author(s):  
Yulin Feng ◽  
Yuexin Hu ◽  
Jinghua Yin ◽  
Guiyan Zhao ◽  
Wei Jiang
2014 ◽  
Vol 71 (12) ◽  
pp. 3305-3321 ◽  
Author(s):  
Kyung-Man Choi ◽  
Sung-Wook Lim ◽  
Myeon-Cheon Choi ◽  
Young-Min Kim ◽  
Dong-Hun Han ◽  
...  

2013 ◽  
Vol 49 (8) ◽  
pp. 2356-2364 ◽  
Author(s):  
Kyung-man Choi ◽  
Myeon-Cheon Choi ◽  
Dong-Hun Han ◽  
Tae-Sung Park ◽  
Chang-Sik Ha

2015 ◽  
Vol 133 (8) ◽  
pp. n/a-n/a ◽  
Author(s):  
Weraporn Pivsa-Art ◽  
Kazunori Fujii ◽  
Keiichiro Nomura ◽  
Yuji Aso ◽  
Hitomi Ohara ◽  
...  

2015 ◽  
Vol 104 ◽  
pp. 48-56 ◽  
Author(s):  
Teresa R. Silva ◽  
Daniela P. Rodrigues ◽  
Jorge M.S. Rocha ◽  
M. Helena Gil ◽  
Susana C.S. Pinto ◽  
...  

2010 ◽  
Vol 447-448 ◽  
pp. 755-759 ◽  
Author(s):  
Jia En Low ◽  
Wei Xiang Koh ◽  
Joon Kit Lai ◽  
Yan Jie Lee ◽  
Xu Li ◽  
...  

Poly(lactic acid) (PLA) is a biodegradable and biocompatible aliphatic polyester whose lactic acid monomers are derived from renewable resources such as corn and sugar beet. As a thermal plastic it can be processed through compounding and injection. As such, we have developed a microfludic device using PLA aimed at blood dialysis application. To quantify the degradation of PLA, its hydrolysis at different pH value was studied. To study the bioresorbable property of these fabricated devices, its decomposition was tested by morphology observation and weight change measurements after embedding in soil under simulated environmental conditions. Upon contact with a hydrophobic surface, platelets and prothrombin are always activated to attach to the surface, resulting in blood clot. This would block the blood flow through the dialysis channels in the microfluidic device. To improve the hydrophilicity, hence the blood compatibility, chemical grafting of a hydrophilic polymer, poly(ethylene oxide) methacrylate (PEGmA), onto the surface of PLA microfluidic device was carried out and the changes in hydrophilicity was monitored through measuring the water contact angle. Our results indicate that chemical grafting of PEGmA significantly improves the hydrophilicity of the device surface.


2021 ◽  
Vol 65 (3) ◽  
pp. 437-451
Author(s):  
Leire Sangroniz ◽  
Teodora Gancheva ◽  
Basil D. Favis ◽  
Alejandro J. Müller ◽  
Antxon Santamaria

2012 ◽  
Vol 20 (12) ◽  
pp. 1300-1306 ◽  
Author(s):  
Jun Yong Park ◽  
Sung Yeon Hwang ◽  
Won Jae Yoon ◽  
Eui Sang Yoo ◽  
Seung Soon Im

Langmuir ◽  
2002 ◽  
Vol 18 (9) ◽  
pp. 3669-3675 ◽  
Author(s):  
C. R. Heald ◽  
S. Stolnik ◽  
K. S. Kujawinski ◽  
C. De Matteis ◽  
M. C. Garnett ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document