Prenatal diagnosis in pregnancies at risk for Joubert syndrome by ultrasound and MRI

2005 ◽  
Vol 25 (6) ◽  
pp. 442-447 ◽  
Author(s):  
Dan Doherty ◽  
Ian A. Glass ◽  
Joseph R. Siebert ◽  
Peter J. Strouse ◽  
Melissa A. Parisi ◽  
...  
2012 ◽  
Vol 32 (7) ◽  
pp. 703-707 ◽  
Author(s):  
Khushnooma Italia ◽  
Jayesh Sheth ◽  
Pratibha Sawant ◽  
Anita Nadkarni ◽  
Kanjaksha Ghosh ◽  
...  
Keyword(s):  
At Risk ◽  

PEDIATRICS ◽  
1974 ◽  
Vol 54 (4) ◽  
pp. 511-513
Author(s):  
D. Gompertz ◽  
Patricia A. Goodey ◽  
J. M. Saudubray ◽  
Christiane Charpentier ◽  
Agnes Chignolle ◽  
...  

The abnormal accumulation of small molecular weight metabolites in amniotic fluid in inborn errors of metabolism is unusual and prenatal diagnosis usually requires amniotic cell culture and specific enzyme assay. However, Morrow et al.1 reported raised concentrations of methylmalonic acid in the amniotic fluid of a pregnancy at risk from methylmalonic aciduria and confirmed the diagnosis in the postnatal period. More recently Mahoney et al.2 have reported an abnormal methylmalonic acid concentration in the amniotic fluid of one of two pregnancies at risk. They confirmed that the fetus in this case was affected by showing an impaired oxidation of methylmalonic acid in cultured amniotic cells.


PEDIATRICS ◽  
1985 ◽  
Vol 76 (5) ◽  
pp. 794-800
Author(s):  
Arleen D. Auerbach ◽  
Michal Sagi ◽  
Barbara Adler

We report our experience, since 1978, with prenatal diagnosis in fetuses at risk for Fanconi anemia. Amniotic fluid cells from 30 fetuses from 24 families were monitored for baseline and diepoxybutane-induced chromosomal breakage. Seven of the fetuses at risk were diagnosed as affected; baseline and diepoxybutane-induced breakage ranged from 0.18 to 0.45 and 0.69 to 0.96 breaks per cell, respectively. The range of baseline and diepoxybutane-induced chromosomal breakage in amniocytes from the 23 pregnancies at risk that were diagnosed prenatally as unaffected ranged from 0 to 0.08 and 0 to 0.13 breaks per cell, respectively. Four of these cases were also diagnosed as normal on the basis of chromosomal breakage studies in cells obtained by chorionic villus sampling. The range of baseline and diepoxybutane-induced breakage in cells from five control fetuses was 0 to 0.05 and 0 to 0.10 breaks per cell, respectively. Of the pregnancies diagnosed as affected, two were carried to term, whereas five were terminated. One newborn and two abortuses had congenital malformations including abnormalities of the thumb and radius. The other affected live-born infant, now 5½ years old, has severe growth retardation and pancytopenia. No Fanconi anemia-associated malformations were found in any of the other fetuses or newborns studied. In all cases in which tissue was available for study, diagnoses were confirmed by chromosome breakage studies. This method thus permits reliable detection of Fanconi anemia.


2020 ◽  
Author(s):  
Line Dahl Jeppesen ◽  
Lotte Hatt ◽  
Ripudaman Singh ◽  
Katarina Ravn ◽  
Mathias Kølvraa ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document