scholarly journals Fast quantitative three‐dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling

2020 ◽  
Vol 33 (10) ◽  
Author(s):  
Lidi Wan ◽  
Yajun Ma ◽  
Jiawei Yang ◽  
Saeed Jerban ◽  
Adam C. Searleman ◽  
...  
2018 ◽  
Vol 49 ◽  
pp. 4-9 ◽  
Author(s):  
Bimin Chen ◽  
Yinghua Zhao ◽  
Xin Cheng ◽  
Yajun Ma ◽  
Eric Y. Chang ◽  
...  

2021 ◽  
Vol 11 ◽  
Author(s):  
Min Jae Cha ◽  
Hye Shin Ahn ◽  
Hyewon Choi ◽  
Hyun Jeong Park ◽  
Thomas Benkert ◽  
...  

PurposeTo investigate the clinical feasibility of accelerated free-breathing stack-of-spirals (spiral) three-dimensional (3D) ultrashort echo time (UTE) lung magnetic resonance imaging (MRI) using iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space (SPIRiT) algorithm in patients with breast cancer.MethodsThe institutional review board approved this prospective study and patients’ informed consents were obtained. Between June and August 2018, 29 female patients with breast cancer underwent 3-T MRI including accelerated free-breathing spiral 3D UTE (0.98-mm isotropic spatial resolution; echo time, 0.05 msec) of the lungs and thin-section chest computed tomography (CT). Two radiologists evaluated the image quality and pulmonary nodules on MRI were assessed and compared, CT as a reference.ResultsThe pulmonary vessels and bronchi were visible consistently up to the sub-sub-segmental and sub-segmental branch levels, respectively, on accelerated spiral 3D UTE. The overall image quality was evaluated as good and excellent for 70.7% of accelerated spiral 3D UTE images (reviewer [R]1, 72.4% [21/29]; R2, 69.0% [20/29]) and acceptable for 20.7% (both R1 and R2, 20.7% [6/29]). Five patients on CT revealed 141 pulmonary metastatic nodules (5.3 ± 2.6 mm); the overall nodule detection rate of accelerated spiral 3D UTE was sensitivity of 90.8% (128/141), accuracy of 87.7%, and positive predictive value of 96.2%. In the Bland-Altman plot analysis comparing nodule size between CT and MRI, 132/141 nodules (93.6%) were inside the limits of agreement.ConclusionAccelerated free-breathing spiral 3D UTE using the SPIRiT algorithm could be a potential alternative to CT for oncology patients.


1999 ◽  
Vol 121 (6) ◽  
pp. 650-656 ◽  
Author(s):  
F. T. Sheehan ◽  
F. E. Zajac ◽  
J. E. Drace

Improper patellar tracking is often considered to be the cause of patellar-femoral pain. Unfortunately, our knowledge of patellar-femoral-tibial (knee) joint kinematics is severely limited due to a lack of three-dimensional, noninvasive, in vivo measurement techniques. This study presents the first large-scale, dynamic, three-dimensional, noninvasive, in vivo study of nonimpaired knee joint kinematics during volitional leg extensions. Cine-phase contrast magnetic resonance imaging was used to measure the velocity profiles of the patella, femur, and tibia in 18 unimpaired knees during leg extensions, resisted by a 34 N weight. Bone displacements were calculated through integration and then converted into three-dimensional orientation angles. We found that the patella displaced laterally, superiorly, and anteriorly as the knee extended. Further, patellar flexion lagged knee flexion, patellar tilt was variable, and patellar rotation was fairly constant throughout extension.


2020 ◽  
Vol 33 (10) ◽  
Author(s):  
Ya‐Jun Ma ◽  
Adam C. Searleman ◽  
Hyungseok Jang ◽  
Shu‐Juan Fan ◽  
Jonathan Wong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document