Determination of the dose rate constant through Monte Carlo simulations with voxel phantoms

2018 ◽  
Vol 45 (11) ◽  
pp. 5283-5292 ◽  
Author(s):  
Abner D. Soares ◽  
Lucas Paixão ◽  
Alessandro Facure
Author(s):  
A Mozaffari ◽  
M Ghorbani

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachytherapy sources by Monte Carlo simulation. Methods: In this study, 60Co (model Co0.A86), 137Cs (model 6520-67), 192Ir (model BEBIG) and 103Pd (model OptiSeed) brachytherapy sources were simulated using MCNPX Monte Carlo code. To simulate the sources, the exact geometric characterization of each source was defined in Monte Carlo input programs. Dosimetric parameters including air kerma strength, dose rate constant, radial dose function and anisotropy function were calculated for each source. Each input program was run with sufficient number of particle histories. The maximum type A statistical uncertainty in the simulation of the 60Co, 137Cs, 192Ir and 103Pd sources, were equal to 4%, 4%, 3.19% and 6.50%, respectively. Results: The results for dosimetry parameters of dose rate constant, radial dose function and anisotropy function for the 60Co, 137Cs, 192Ir and 103Pd sources in this study demonstrated good agreement with other studies. Conclusion: Based on the good agreement between the results of this study and other studies, the TG-43 results for Co0.A86 60Co, 67-65200 137Cs, BEBIG 192Ir and OptiSeed 103Pd sources are validated and can be used as input data in treatment planning systems (TPSs) and to validate the TPS calculations.


2002 ◽  
Vol 29 (7) ◽  
pp. 1637-1638 ◽  
Author(s):  
Geoffrey S. Ibbott ◽  
Ali S. Meigooni ◽  
Darren M. Gearheart
Keyword(s):  

2016 ◽  
Vol 43 (6Part13) ◽  
pp. 3469-3469
Author(s):  
S Tsuji ◽  
M Oita ◽  
N Narihiro

MRS Advances ◽  
2017 ◽  
Vol 2 (48) ◽  
pp. 2627-2632 ◽  
Author(s):  
Poppy Siddiqua ◽  
Michael S. Shur ◽  
Stephen K. O’Leary

ABSTRACTWe examine how stress has the potential to shape the character of the electron transport that occurs within ZnO. In order to narrow the scope of this analysis, we focus on a determination of the velocity-field characteristics associated with bulk wurtzite ZnO. Monte Carlo simulations of the electron transport are pursued for the purposes of this analysis. Rather than focusing on the impact of stress in of itself, instead we focus on the changes that occur to the energy gap through the application of stress, i.e., energy gap variations provide a proxy for the amount of stress. Our results demonstrate that stress plays a significant role in shaping the form of the velocity-field characteristics associated with ZnO. This dependence could potentially be exploited for device application purposes.


2012 ◽  
Vol 39 (1) ◽  
pp. 40-47 ◽  
Author(s):  
Guillaume Guérin ◽  
Norbert Mercier

Abstract The determination of gamma dose rates is of prior importance in the field of luminescence dating methods. In situ measurements are usually performed by the insertion of dosimeters or a portable gamma spectrometer cell in sediments. In this paper, Monte-Carlo simulations using the Geant4 toolkit allow the development of a new technique of insitu gamma dose rate evaluations: a spectrometer cell is placed on the surface of sediments under excavation to acquire successive spectra as sediments are removed by excavations. The principle of this non-invasive technique is outlined and its potential is discussed, especially in the case of environments in which radioelements are heterogeneously distributed. For such cases, a simple method to reconstruct gamma dose rate values with surface measurements using an attenuator is discussed, and an estimation of errors is given for two simple cases. This technique appears to be applicable, but still needs experimental validation.


Sign in / Sign up

Export Citation Format

Share Document