A simple formulation for deriving effective atomic numbers via electron density calibration from dual-energy CT data in the human body

2017 ◽  
Vol 44 (6) ◽  
pp. 2293-2303 ◽  
Author(s):  
Masatoshi Saito ◽  
Shota Sagara
2021 ◽  
Vol 16 (9) ◽  
pp. 2343-2346
Author(s):  
Shota Yamamoto ◽  
Shunsuke Kamei ◽  
Kosuke Tomita ◽  
Chikara Fujita ◽  
Kazuyuki Endo ◽  
...  

2017 ◽  
Vol 123 ◽  
pp. S912
Author(s):  
C. Möhler ◽  
P. Wohlfahrt ◽  
C. Richter ◽  
S. Greilich

2019 ◽  
Vol 24 (5) ◽  
pp. 499-506
Author(s):  
Daisuke Kawahara ◽  
Shuichi Ozawa ◽  
Kazushi Yokomachi ◽  
Toru Higaki ◽  
Takehiro Shiinoki ◽  
...  

2016 ◽  
Vol 43 (6Part9) ◽  
pp. 3423-3423
Author(s):  
G Michalak ◽  
A Halaweish ◽  
B Krauss ◽  
J Fletcher ◽  
C McCollough

2016 ◽  
Vol 43 (6Part35) ◽  
pp. 3756-3756 ◽  
Author(s):  
S Zhang ◽  
D Han ◽  
D Politte ◽  
M Porras-Chaverri ◽  
B Whiting ◽  
...  

2014 ◽  
Vol 41 (6Part1) ◽  
pp. 061714 ◽  
Author(s):  
Nora Hünemohr ◽  
Harald Paganetti ◽  
Steffen Greilich ◽  
Oliver Jäkel ◽  
Joao Seco

2016 ◽  
Author(s):  
Christian David Trujillo-Bastidas ◽  
Olivia Amanda García-Garduño ◽  
José Manuel Lárraga-Gutiérrez ◽  
Arnulfo Martínez-Dávalos ◽  
Mercedes Rodríguez-Villafuerte

2020 ◽  
Author(s):  
Lin Qiu ◽  
Junjiao Hu ◽  
Zeping Weng ◽  
Fasheng Li ◽  
Fei Wang ◽  
...  

Abstract Background To explore the ability of Dual-energy CT (DECT) to differentiate metastatic from non-metastatic lymph nodes in colorectal cancer (CRC). Methods Seventy-one patients with primary CRC underwent contrast-enhanced DECT imaging before surgery. The colorectal specimen was scanned after surgery, and lymph nodes were matched to the pathology report. The DECT quantitative parameters were analyzed: dual-energy curve slope value(λHU), standardized iodine concentration (n△HU), iodine water ratio (nIWR), electron density value (nρeff), and effective atom-number (nZ), for the metastatic and non-metastatic lymph node differentiation. Also, sensitivity and specificity analyses were performed by using receiver operating characteristic curve. Results One hundred and fifty lymph nodes including 66 non-metastatic and 84 metastatic lymph nodes were matched using the radiological-pathological correlation. Metastatic node had a significantly greater λHU, n△HU and nIWR values than non-metastatic node in both arterial and venous phases (P < 0.01). The AUC, sensitivity and specificity were 0.80, 80.30% and 65.48% for λHU; 0.86, 69.70% and 95.24% for n△HU; 0.88, 71.21% and 95.24% for nIWR in the arterial phase. No significant difference was found in electron density and effective Z value for differentiation. Conclusion Dual-energy CT quantitative parameters may be helpful in diagnosing metastatic lymph nodes of CRC.


Sign in / Sign up

Export Citation Format

Share Document