Kinetics studies of 5‐methyl‐2‐hexanol, 2,2‐dimethyl‐3‐hexanol, and 2,4,4‐trimethyl‐1‐pentanol with chlorine atoms: Photooxidation mechanism of 2,4,4‐trimethyl‐1‐pentanol

2019 ◽  
Vol 52 (1) ◽  
pp. 29-34
Author(s):  
Jesús A. Vila ◽  
Gustavo A. Argüello ◽  
Fabio E. Malanca
Author(s):  
D.W. Susnitzky ◽  
S.R. Summerfelt ◽  
C.B. Carter

Solid-state reactions have traditionally been studied in the form of diffusion couples. This ‘bulk’ approach has been modified, for the specific case of the reaction between NiO and Al2O3, by growing NiAl2O4 (spinel) from electron-transparent Al2O3 TEM foils which had been exposed to NiO vapor at 1415°C. This latter ‘thin-film’ approach has been used to characterize the initial stage of spinel formation and to produce clean phase boundaries since further TEM preparation is not required after the reaction is completed. The present study demonstrates that chemical-vapor deposition (CVD) can be used to deposit NiO particles, with controlled size and spatial distributions, onto Al2O3 TEM specimens. Chemical reactions do not occur during the deposition process, since CVD is a relatively low-temperature technique, and thus the NiO-Al2O3 interface can be characterized. Moreover, a series of annealing treatments can be performed on the same sample which allows both Ni0-NiAl2O4 and NiAl2O4-Al2O3 interfaces to be characterized and which therefore makes this technique amenable to kinetics studies of thin-film reactions.


1984 ◽  
Vol 52 (01) ◽  
pp. 015-018 ◽  
Author(s):  
A Girolami ◽  
A Sticchi ◽  
R Melizzi ◽  
L Saggin ◽  
G Ruzza

SummaryLaser nephelometry is a technique which allows the evaluation of the concentration of several serum proteins and clotting factors. By means of this technique it is also possible to study the kinetics of the reaction between antigen and antibody. We studied the kinetics of the reaction between prothrombin and an antiprothrombin antiserum using several prothrombins namely: Prothrombin Padua, prothrombin Molise, which are two congenital dysprothrombinemias, cirrhotic, coumarin or normal prothrombins. Different behaviors in the kinetics of the reactions were shown even when the concentration of prothrombins was about the same in all plasma tested. These differences were analyzed by means of a computer (Apple II 48 RAM) programmed to solve four unknown equations (Rodbard’s equation). From the data so obtained one can see that when voltages at the beginning and at the end of the reaction are in all cases about the same, a clear difference in the time required to reach half the maximum value of the voltage can still be demonstrated. This parameter, which is expressed in minutes, is longer in coumarin and prothrombin Molise than in controls. On the contrary it is shorter in prothrombin Padua and has about the same value of controls in the cirrhotic patient. Moreover the time at which the maximum rate is obtained is longer in coumarin and prothrombin Molise than in controls and shorter in liver cirrhosis and prothrombin Padua. In conclusion data obtained show that coumarin prothrombin behaves in a different way from cirrhotic prothrombin and also that there is a different behaviour between the two congenital dysprothrombinemias.


Author(s):  
Mohd Jumain Jalil ◽  
Aliff Farhan Mohd Yamin ◽  
Mohd Saufi Md Zaini ◽  
Veronique Gloria V. Siduru ◽  
Norhashimah Morad ◽  
...  

Background: Studies pertaining to the epoxidation of fatty acids, garnered much interest in recent years due to the rising demand of eco-friendly epoxides derived from vegetable oils. Methods: Epoxide is an important chemical precursor for the production of alcohols, glycols and polymers, like polyesters and epoxy resin. Epoxidation is the name given to the reaction when the double bonds are converted into epoxide. Results: Temperature at 55oC was used as a reference material in the epoxide process, as it produces a high yield epoxide being 88%. The kinetic rate of epoxidized palm kernel oil, k was obtained to be k11= 0.5125, k12= 0.05045, k21= 0.03185, k41= 0.01 and k51= 0.01243. Conclusion: Hence, by fitting the result with the experimental work and simulation, the summation of error being stimulated by I-sight simulation was 0.731116428 and the correlation between the experimental and simulation data was 0.925544.


Sign in / Sign up

Export Citation Format

Share Document