Simultaneous determination of metformin and glimepride in pharmaceutical dosage form by reverse-phase liquid chromatography

2005 ◽  
Vol 28 (16) ◽  
pp. 2076-2079 ◽  
Author(s):  
Bhaskar Laxmanrao Kolte ◽  
Bharat Baburao Raut ◽  
Adwait Anant Deo ◽  
Manoj Anil Bagool ◽  
Devanand Baburao Shinde
1988 ◽  
Vol 71 (3) ◽  
pp. 462-465
Author(s):  
Pietro Damiani ◽  
Giovanni Burini

Abstract Two procedures, one fluorometric and the other reverse phase liquid chromatographic, for determination of a derivative of diacetyl are described. Exploratory work on diacetyl standard solutions to establish the best conditions for the derivatization with 2,3-diaminonaphthalene (DAN) to yield 2,3-dimethylbenzo[g]-quinoxaline (DMBQ) is discussed, as well as the fluorescence characteristics of the DMBQ derivative. Diacetyl was determined in 10 commercial butter samples by the proposed procedures and by other known methods (determination of o-phenylenediamine and 3,3-diaminobenzidinederivatives). Recoveries from butter samples spiked with known amounts of diacetyl ranged from 96.9 to 101.8% (with CVs ranging from 0.3 to 2.1%) for the fluorometric procedure and from 96.9 to 102.7% (with CVs ranging from 0.5 to 2.4%) for the chromatographic procedure. These results agree well with those obtained with o-phenylenediamine and 3,3-diaminobenzidine methods on the same butter samples. The proposed methods have the advantages of improved detectability and specificity.


1986 ◽  
Vol 69 (5) ◽  
pp. 856-859 ◽  
Author(s):  
Sheldon D West ◽  
Edgar W Day

Abstract A residue method is described for determination of the aquatic herbicide fluridone (1-methy1-3-phenyl-5-[3-(trifluoromethyl)phenyl]-4(1H)- pyridinone) and its metabolite (1-methy1-3-(4-hydroxyphenyl)-5-[3- (trifluoromethyl)phenyl]-4(1H)-pyridinone) in fish and crayfish tissues. Both compounds are extracted from tissues with methanol, and the extracts are subjected to acidic hydrolysis to release conjugated forms of fluridone and the metabolite. Sample extracts are purified by liquidliquid partitioning and Florisil Sep-Pak® column chromatography. Both compounds are separated and measured by reverse phase liquid chromatography with UV detection at 313 nm. In the absence of interfering peaks, the method has a detection limit of approximately 0.04 ppm of either compound. Overall, recoveries averaged 96% for fluridone and 78% for the metabolite for all tissue types combined.


Sign in / Sign up

Export Citation Format

Share Document