scholarly journals Procedural outcome of lead explant and countertraction‐assisted femoral lead extraction in Thai patients with cardiac implantable electronic device infection

2021 ◽  
Author(s):  
Jirarat Jiratham‐Opas ◽  
Narawudt Prasertwitayakij ◽  
Teerapat Nantsupawat ◽  
Wanwarang Wongcharoen
EP Europace ◽  
2019 ◽  
Vol 21 (9) ◽  
pp. 1378-1384 ◽  
Author(s):  
Frank Bracke ◽  
Niels Verberkmoes ◽  
Marcel van 't Veer ◽  
Berry van Gelder

Abstract Aims Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection. Methods and results All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6–38.2) and 11.6 (5.6–17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration. Conclusion Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.


2021 ◽  
Author(s):  
Jakrin Kewcharoen ◽  
Chanavuth Kanitsoraphan ◽  
Sittinun Thangjui ◽  
Thiratest Leesutipornchai ◽  
Sakditad Saowapa ◽  
...  

2021 ◽  
pp. 102568
Author(s):  
Fatehi Elzein ◽  
Eid Alsufyani ◽  
Yahya Al Hebaishi ◽  
Mohammed Mosaad ◽  
Moayad Alqurashi ◽  
...  

Hearts ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 202-212
Author(s):  
Giulia Massaro ◽  
Igor Diemberger ◽  
Matteo Ziacchi ◽  
Andrea Angeletti ◽  
Giovanni Statuto ◽  
...  

In recent decades there has been a relevant increase in the implantation rate of cardiac implantable electronic devices (CIEDs), albeit with relevant geographical inhomogeneities. Despite the positive impact on clinical outcomes, the possibility of major complications is not negligible, particularly with respect to CIED infections. CIED infections significantly affect morbidity and mortality, especially in instances of delayed diagnosis and appropriate treatment. In the present review, we will start to depict the factors underlying the development of CIED infection as well as the difficulties related to its diagnosis and treatment. We will explain the reasons underlying the need to focus on prophylaxis rather than treatment, in view of the poor outcomes despite improvements in lead extraction procedures. This will lead to the consideration of management of this complication in a hub-spoke manner, and to our analysis of the several technological and procedural improvements developed to minimize this complication. These include prolongation of CIED longevity, the development of leadless devices, and integrated prophylactic approaches. We will conclude with a discussion regarding new devices and strategies under development. This complete excursus will provide the reader with a new perspective on how a major complication can drive technological improvements.


Heart Rhythm ◽  
2017 ◽  
Vol 14 (12) ◽  
pp. 1807-1811 ◽  
Author(s):  
Amr F. Barakat ◽  
Oussama M. Wazni ◽  
Khaldoun Tarakji ◽  
Walid I. Saliba ◽  
Nayef Nimri ◽  
...  

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Jakrin Kewcharoen ◽  
Chanavuth Kanitsoraphan ◽  
Sittinun Thangjui ◽  
Thiratest Leesutipornchai ◽  
Leenhapong Navaravong

Introduction: Several studies have shown inconsistent relationship between post-implantation hematoma (PH) and cardiac implantable electronic device (CIED) infection. In this study, we performed a systematic review and meta-analysis to explore the effect of PH and the risk of CIED infection. Hypothesis: PH increases the risk of CIED infection. Methods: We searched the databases of MEDLINE and EMBASE from inception to March 2020. Included studies were cohort studies, case-control studies, cross-sectional studies and randomized controlled trials that reported incidence of PH and CIED infection during the follow-up period. CIED infection was defined as either a device-related local or systemic infection. Data from each study were combined using the random-effects, generic inverse variance method of Der Simonian and Laird to calculate odds ratios (OR) and 95% confidence intervals (CI). Results: Fourteen studies from 2006 to 2018 were included, involving a total of 28,319 participants. There were 6 cohort studies, 7 case-control studies and 1 randomized controlled trial. In random-effect model, we found that PH significantly increases the risk of overall CIED infection (OR = 6.30, 95%CI: 3.87-10.24, I2=49.3%) (Figure 1). There was no publication bias observed in the funnel plot as well as no small-study effect observed in Egger’s test. Conclusions: Our meta-analysis demonstrated that PH significantly increases the risk of CIED infection. Precaution should be taken to during device implantation to reduce PH and subsequent CIED infection.


2017 ◽  
Vol 84 (12 suppl 3) ◽  
pp. 47-53 ◽  
Author(s):  
Cameron T. Lambert ◽  
Khaldoun G. Tarakji

EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
M Giannotti Santoro ◽  
L Segreti ◽  
G Zucchelli ◽  
V Barletta ◽  
F Fiorentini ◽  
...  

Abstract Introduction the management of patients with infection or malfunction of a cardiac implantable electronic device (CIED) may be challenging. Purpose The aim of the study is to evaluate the safety and efficacy of transvenous lead extraction (TLE) in elderly patients. Methods a retrospective analysis of patients who underwent to TLE in our center was performed. Patients were divided in two groups: 1) patients 80 years of age or older, 2) patients younger than 80 years. All patients were treated with manual traction or mechanical dilatation. Results our analysis included 1316 patients, with a total of 2513 leads extracted. Group 1 (≥80 years) counted 202 patients and group 2 (<80 years) 1114 patients. The group of elderly patients presented more comorbidities, as hypertension, chronic kidney disease, atrial fibrillation and pulmonary disease. Patients 80 years of age or older had more pacemakers than ICDs, whereas the dwelling time of the oldest lead, the number of leads and the presence of abandoned leads was similar despite patients age. In group 1 the rate of radiological success for lead was higher than in group 2 (99.0% vs 95.9%; P < 0.001). The clinical success was obtained in 1273 patients (96.7%), without significative differences between groups (98.0% vs 96.4%; P = 0.36). Major complications occurred in 10 patients (0.7%), without significative differences (1.5% vs 0.6%; P = 0.24) (figure 1). Conclusion TLE in elderly patients is a safe and effective procedure. In patients older than 80 years there are not more major complications than in younger patients, and the efficacy of the procedure seems to be superior. Abstract Figure 1