Chest PET / MRI in Solid Cancers: Comparing the Diagnostic Performance of a Free‐Breathing 3D‐T1‐GRE Stack‐of‐Stars Volume Interpolated Breath‐Hold Examination ( StarVIBE ) Acquisition With That of a 3D‐T1‐GRE Volume Interpolated Breath‐Hold Examination ( VIBE ) for Chest Staging During Whole‐Body PET / MRI

Author(s):  
Mathilde Vermersch ◽  
Berivan Emsen ◽  
Aurélien Monnet ◽  
Julia Chalaye ◽  
Athena Galletto Pregliasco ◽  
...  
Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Sarah M Schwartz ◽  
Ashitha Pathrose ◽  
Ali Serhal ◽  
Ryan Avery ◽  
Ann Ragin ◽  
...  

Introduction: Wideband late gadolinium enhancement (LGE) CMR is capable of suppressing image artifacts induced by cardiac implanted electronic devices (CIEDs). We implemented our own wideband segmented (seg) breath-hold and wideband single-shot (SS) free-breathing LGE pulse sequences and used them clinically since 2016. The purpose of this study was to evaluate image quality and CMR safety of wideband LGE compared to standard LGE. Methods: We retrospectively identified 54 consecutive patients (mean age: 61±15 years; 31% females) with CIED (33 t-ICD, 4 s-ICD, 15 pacemaker, 1 CRT-D, 1 CRT-P) who underwent CMR at 1.5T (Avanto, Siemens). Standard seg, wideband seg, and wideband SS LGE used standard imaging parameters. 16 myocardial segments were scored for scar/myocardial conspicuity and presence of any visual artifact on a 5-point Likert scale (1:worst; 3:acceptable; 5:best). Distance between center of the heart and CIED (CXR D) was measured on chest X-ray. Whole-body specific absorption rate (SAR) was read from DICOM metadata. Device changes were calculated from pre- and post- device interrogation measurements. Results: Both wideband seg and SS LGE consistently produced better image quality than standard LGE (Figure 1A). Median conspicuity and artifact scores were significantly better for wideband seg (F=20.6, p<0.001) and wideband SS (F=24.2, p<0.001) LGE compared to standard LGE. There was a trend in conspicuity and artifact scores with CIED distance for standard LGE (rho=0.476, p=0.02), but not wideband LGE scans (Figure 1B, 1C). Whole-body SAR averaged for both wideband scans (0.15±0.04 W/kg) was one order of magnitude below the 2.0 W/kg FDA limit. Device parameters (sensing, impedance, threshold, battery level) did not differ before and after CMR including wideband LGE. Conclusions: Both wideband seg and SS LGE scans produced improved image quality compared to standard LGE while maintaining CMR safety. *The first two authors (SS and AP) contributed equally


2020 ◽  
Vol 22 (1) ◽  
Author(s):  
Pascale Aouad ◽  
Ioannis Koktzoglou ◽  
Bastien Milani ◽  
Ali Serhal ◽  
Jose Nazari ◽  
...  

Abstract Background Computed tomography angiography (CTA) or contrast-enhanced (CE) cardiovascular magnetic resonance angiography (CMRA) is often obtained in patients with atrial fibrillation undergoing evaluation prior to pulmonary vein (PV) isolation. Drawbacks of CTA include radiation exposure and potential risks from iodinated contrast agent administration. Free-breathing 3D balanced steady-state free precession (bSSFP) Non-contrast CMRA is a potential imaging option, but vascular detail can be suboptimal due to ghost artifacts and blurring that tend to occur with a Cartesian k-space trajectory or, in some cases, inconsistent respiratory gating. We therefore explored the potential utility of both breath-holding and free-breathing non-contrast CMRA, using radial k-space trajectories that are known to be less sensitive to flow and motion artifacts than Cartesian. Main body Free-breathing 3D Cartesian and radial stack-of-stars acquisitions were compared in 6 healthy subjects. In addition, 27 patients underwent CTA and non-contrast CMRA for PV mapping. Three radial CMR acquisition strategies were tested: (1) breath-hold (BH) 2D radial bSSFP (BH-2D); (2) breath-hold, multiple thin-slab 3D stack-of-stars bSSFP (BH-SOS); and (3) navigator-gated free-breathing (FB) 3D stack-of-star bSSFP using a spatially non-selective RF excitation (FB-NS-SOS). A non-rigid registration algorithm was used to compensate for variations in breath-hold depth. In healthy subjects, image quality and vessel sharpness using a free-breathing 3D SOS acquisition was significantly better than free-breathing (FB) Cartesian 3D. In patients, diagnostic image quality was obtained using all three radial CMRA techniques, with BH-SOS and FB-NS-SOS outperforming BH-2D. There was overall good correlation for PV maximal diameter between BH-2D and CTA (ICC = 0.87/0.83 for the two readers), excellent correlation between BH-SOS and CTA (ICC = 0.90/0.91), and good to excellent correlation between FB-NS-SOS and CTA (ICC = 0.87/0.94). For PV area, there was overall good correlation between BH-2D and CTA (ICC = 0.79/0.83), good to excellent correlation between BH-SOS and CTA (ICC = 0.88/0.91) and excellent correlation between FB-NS-SOS and CTA (ICC = 0.90/0.95). CNR was significantly higher with BH-SOS (mean = 11.04) by comparison to BH-2D (mean = 6.02; P = 0.007) and FB-NS-SOS (mean = 5.29; P = 0.002). Conclusion Our results suggest that a free-breathing stack-of-stars bSSFP technique is advantageous in providing accurate depiction of PV anatomy and ostial measurements without significant degradation from off-resonance artifacts, and with better image quality than Cartesian 3D. For patients in whom respiratory gating is unsuccessful, a breath-hold thin-slab stack-of-stars technique with retrospective motion correction may be a useful alternative.


Pneumologie ◽  
2012 ◽  
Vol 66 (06) ◽  
Author(s):  
D Maxien ◽  
M Ingrisch ◽  
F Meinel ◽  
S Thieme ◽  
MF Reiser ◽  
...  

2020 ◽  
Vol 91 (7) ◽  
pp. 578-585
Author(s):  
Victory C. Madu ◽  
Heather Carnahan ◽  
Robert Brown ◽  
Kerri-Ann Ennis ◽  
Kaitlyn S. Tymko ◽  
...  

PURPOSE: This study was intended to determine the effect of skin cooling on breath-hold duration and predicted emergency air supply duration during immersion.METHODS: While wearing a helicopter transport suit with a dive mask, 12 subjects (29 ± 10 yr, 78 ± 14 kg, 177 ± 7 cm, 2 women) were studied in 8 and 20°C water. Subjects performed a maximum breath-hold, then breathed for 90 s (through a mouthpiece connected to room air) in five skin-exposure conditions. The first trial was out of water for Control (suit zipped, hood on, mask off). Four submersion conditions included exposure of the: Partial Face (hood and mask on); Face (hood on, mask off); Head (hood and mask off); and Whole Body (suit unzipped, hood and mask off).RESULTS: Decreasing temperature and increasing skin exposure reduced breath-hold time (to as low as 10 ± 4 s), generally increased minute ventilation (up to 40 ± 15 L · min−1), and decreased predicted endurance time (PET) of a 55-L helicopter underwater emergency breathing apparatus. In 8°C water, PET decreased from 2 min 39 s (Partial Face) to 1 min 11 s (Whole Body).CONCLUSION: The most significant factor increasing breath-hold and predicted survival time was zipping up the suit. Face masks and suit hoods increased thermal comfort. Therefore, wearing the suits zipped with hoods on and, if possible, donning the dive mask prior to crashing, may increase survivability. The results have important applications for the education and preparation of helicopter occupants. Thermal protective suits and dive masks should be provided.Madu VC, Carnahan H, Brown R, Ennis K-A, Tymko KS, Hurrie DMG, McDonald GK, Cornish SM, Giesbrecht GG. Skin cooling on breath-hold duration and predicted emergency air supply duration during immersion. Aerosp Med Hum Perform. 2020; 91(7):578–585.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Szilvia Gaál ◽  
Zsuzsanna Kahán ◽  
Viktor Paczona ◽  
Renáta Kószó ◽  
Rita Drencsényi ◽  
...  

Abstract Background Studying the clinical utility of deep-inspirational breath-hold (DIBH) in left breast cancer radiotherapy (RT) was aimed at focusing on dosimetry and feasibility aspects. Methods In this prospective trial all enrolled patients went through planning CT in supine position under both DIBH and free breathing (FB); in whole breast irradiation (WBI) cases prone CT was also taken. In 3-dimensional conformal radiotherapy (3DCRT) plans heart, left anterior descending coronary artery (LAD), ipsilateral lung and contralateral breast doses were analyzed. The acceptance of DIBH technique as reported by the patients and the staff was analyzed; post-RT side-effects including radiation lung changes (visual scores and lung density measurements) were collected. Results Among 130 enrolled patients 26 were not suitable for the technique while in 16, heart or LAD dose constraints were not met in the DIBH plans. Among 54 and 34 patients receiving WBI and postmastectomy/nodal RT, respectively with DIBH, mean heart dose (MHD) was reduced to < 50%, the heart V25 Gy to < 20%, the LAD mean dose to < 40% and the LAD maximum dose to about 50% as compared to that under FB; the magnitude of benefit was related to the relative increase of the ipsilateral lung volume at DIBH. Nevertheless, heart and LAD dose differences (DIBH vs. FB) individually varied. Among the WBI cases at least one heart/LAD dose parameter was more favorable in the prone or in the supine FB plan in 15 and 4 cases, respectively; differences were numerically small. All DIBH patients completed the RT, inter-fraction repositioning accuracy and radiation side-effects were similar to that of other breast RT techniques. Both the patients and radiographers were satisfied with the technique. Conclusions DIBH is an excellent heart sparing technique in breast RT, but about one-third of the patients do not benefit from that otherwise laborious procedure or benefit less than from an alternative method. Trial registration: retrospectively registered under ISRCTN14360721 (February 12, 2021)