Evaluation of the bond strengths of restorative materials to primary tooth dentin treated with different pulpotomy techniques

Author(s):  
Basak Bolukbasi ◽  
Ebru Kucukyilmaz
2020 ◽  
Vol 12 (4) ◽  
pp. 189
Author(s):  
Nurullah Turker ◽  
Ulviye Şebnem Buyukkaplan ◽  
Ebru Kaya Başar ◽  
Mehmet Mustafa Özarslan

2018 ◽  
Vol 10 (3) ◽  
pp. 235-240 ◽  
Author(s):  
Mehrsa Paryab ◽  
Shahrzad Sharifi ◽  
Mohammad Javad Kharazifard ◽  
Nazanin Kumarci

Introduction: One of the main applications of laser in dentistry is the removal of dental caries and preparation of restorative cavities. The morphology and wettability of laser prepared surfaces are different from that of those prepared with conventional method which may affect the quality of the adhesive potential of bonding agents in these surfaces. This study aimed to assess the shear bond strength of a total-etch and self-etch adhesive system to primary tooth dentin prepared by two different energy densities of Er:YAG laser in comparison with surfaces prepared by bur. Methods: A total of 60 human primary second molars extracted for orthodontic purposes were selected and randomly divided into 3 main groups of equal (n=20). Group A: Preparation of dentin surface by bur; group B: Preparation of dentin surface by laser with 300 mJ energy level; group C: Preparation of dentin surface by laser with 400 mJ energy level. In each of the main groups, the teeth were randomly assigned to 2 subgroups. Composite resin material was bonded with the total-etch adhesive system in subgroups A1, B1, and C1 and with the self-etch adhesive system in subgroups A2, B2, and C2. The samples were thermo-cycled, and composite restorations shear bond strength was measured in MPa. Data were analyzed using two-way analysis of variance (ANOVA), and P values less than 0.05 were considered statistically significant. Results: The highest and the lowest shear bond strength values were observed in group A2 (Preparation by bur- Composite resin material bonded by Clearfil SE Bond) and group C2 (Preparation by laser with 400 mJ energy level - Composite resin material bonded by Clearfil SE Bond), respectively. The results showed no statistically significant differences between the study subgroups (P > 0.05). Conclusion: It is concluded that in terms of shear bond strength to dentin, Single Bond and Clearfil SE Bond adhesive agents adequately perform in primary tooth dentin prepared by Er: YAG laser with energy levels of 300 and 400 mJ and frequency of 10 Hz.


2021 ◽  
Vol 17 (2) ◽  
pp. 108-115
Author(s):  
Merve Yılmaz Güneş ◽  
Hakan Göktürk ◽  
Emine Şirin Karaarslan

2017 ◽  
Vol 41 (3) ◽  
pp. 214-218 ◽  
Author(s):  
Tathiane Larissa Lenzi ◽  
Fabio Zovico Maxnuck Soares ◽  
Rachel de Oliveira Rocha

Objective: To evaluate the effect of bonding strategy on microtensile bond strength (μTBS) of a new universal adhesive system to primary tooth dentin. Study design: Flat dentin surfaces from 25 primary molars were assigned to 5 groups according to the adhesive and bonding approach: Adper Single Bond 2 (two-step etch-and-rinse adhesive) and Clearfil SE Bond (two-step self-etch system), as controls; Scotchbond Universal Adhesive–self-etch, dry or wet-bonding etch-and-rinse strategies. Composite buildups were constructed and the teeth were sectioned to obtain bonded sticks (0.8 mm2) to be tested under tension at 1mm/min. The μTBS means were analyzed by one-way ANOVA and Tukey's tests (α = 0.05). Failure mode was evaluated using a stereomicroscope (400×). Results: Universal adhesive applied following both dry and wet-bonding etch-and-rinse strategies showed similar bond strength compared with control adhesive systems. Self-etch approach resulted in the lowest μTBS values. For all groups, adhesive/mixed failure prevailed. The percentage of premature debonded specimens was higher when the universal adhesive was used as self-etch mode. Conclusion: The universal adhesive does not share the same versatility of being used in the etch-and-rinse and self-etch approaches; however, the use of the new adhesive following either wet or dry-bonding may be a suitable option as alternative to two-step etch-and-rinse adhesive protocol.


2010 ◽  
Vol 38 (5) ◽  
pp. 423-430 ◽  
Author(s):  
Y. Hosoya ◽  
S. Ando ◽  
K. Yamaguchi ◽  
S. Oooka ◽  
M. Miyazaki ◽  
...  
Keyword(s):  

2017 ◽  
Vol 40 (12) ◽  
pp. 709-713
Author(s):  
Kadriye G.U. Güzel ◽  
Ayşe C. Altun ◽  
Zuhal Kirzioğlu

Purpose Many novel materials have been developed such as composite resin, ceramic, zircon or metal-supported ceramic for use in aesthetic restoration of primary teeth and permanent teeth with extensive crown damage. The aim of the present study was to compare microtensile bond strengths on materials using the microtensile bond strength test. Materials and methods The microtensile bond strength on the primary tooth dentin was measured on extracted primary teeth using an indirect method and fracture patterns were evaluated. Results The analysis of bond strengths using the Mann-Whitney U-test did not show significant difference between the rank averages of the compomer and composite resin (p = 0.741). The dentin sections, from which test samples were obtained, contributed to the bond strength; dentin samples obtained just above the pulp had lower bond strength, and the difference was statistically significant (p = 0.005). The adhesive type fracture was the most prevalent fracture type for both materials. Conclusions When the chemical, physiological, and micromorphological differences between primary and permanent teeth are taken into consideration, the success of the materials used for restorations can be different between primary and permanent teeth. Therefore, materials used in the dentistry must be evaluated separately for primary teeth.


2005 ◽  
Vol 29 (3) ◽  
pp. 221-224 ◽  
Author(s):  
P. Villalta ◽  
C.R. Rodrigues

Since primary tooth enamel wears more rapidly than permanent tooth enamel, it is important to study the mechanical wear patterns of restorative materials used in the primary dentition. It is important that an in vitro evaluation of wear resistance of different restorative materials is done in order to establish a valid in vitro test protocol for use in pediatric dentistry.


Sign in / Sign up

Export Citation Format

Share Document