Capitalizing on the treatment planning process to enhance dental education

Author(s):  
Viyan S. Kadhium ◽  
Katherine Shin ◽  
Vidya Ramaswamy ◽  
Romesh P. Nalliah
2015 ◽  
Vol 49 (1) ◽  
pp. 1-9 ◽  
Author(s):  
Stasa Jelercic ◽  
Mirjana Rajer

AbstractBackground. PET-CT is becoming more and more important in various aspects of oncology. Until recently it was used mainly as part of diagnostic procedures and for evaluation of treatment results. With development of personalized radiotherapy, volumetric and radiobiological characteristics of individual tumour have become integrated in the multistep radiotherapy (RT) planning process. Standard anatomical imaging used to select and delineate RT target volumes can be enriched by the information on tumour biology gained by PET-CT. In this review we explore the current and possible future role of PET-CT in radiotherapy treatment planning. After general explanation, we assess its role in radiotherapy of those solid tumours for which PET-CT is being used most.Conclusions. In the nearby future PET-CT will be an integral part of the most radiotherapy treatment planning procedures in an every-day clinical practice. Apart from a clear role in radiation planning of lung cancer, with forthcoming clinical trials, we will get more evidence of the optimal use of PET-CT in radiotherapy planning of other solid tumours


2021 ◽  
pp. 20210214
Author(s):  
Hanlin Wang ◽  
Ruoxi Wang ◽  
Jiacheng Liu ◽  
Jian Zhang ◽  
Kaining Yao ◽  
...  

Objectives: To develop and evaluate a practical automatic treatment planning method for Intensity-Modulated Radiation Therapy (IMRT) in cervical cancer cases. Methods: A novel algorithm named as Optimization Objectives Tree Search Algorithm (OOTSA) was proposed to emulate the planning optimization process and achieve a progressively improving IMRT plan, based on the Eclipse Scripting Application Programming Interface (ESAPI). Thirty previously treated cervical cancer cases were selected from the clinical database and comparison was made between the OOTSA-generated plans and clinical treated plans and RapidPlan-based (RP) plans. Results: In clinical evaluation, compared with plan scores of the clinical plans and the RP plans, 22 and 26 of the OOTSA plans were considered as clinically improved in terms of plan quality, respectively. The average conformity index (CI) for the PTV in the OOTSA plans was 0.86 ± 0.01 (mean ± 1 standard deviation), better than those in the RP plans (0.83 ± 0.02) and the clinical plans (0.71 ± 0.11). Compared with the clinical plans, the mean doses of femoral head, rectum, spinal cord and right kidney in the OOTSA plans were reduced by 2.34 ± 2.87 Gy, 1.67 ± 2.10 Gy, 4.12 ± 6.44 Gy and 1.15 ± 2.67 Gy. Compared with the RP plans, the mean doses of femoral head, spinal cord, right kidney and small intestine in the OOTSA plans were reduced by 3.31 ± 1.55 Gy, 4.25 ± 3.69 Gy, 1.54 ± 2.23 Gy and 3.33 ± 1.91 Gy, respectively. In the OOTSA plans, the mean dose of bladder was slightly increased, with 2.33 ± 2.55 Gy (versus clinical plans) and 1.37 ± 1.74 Gy (versus RP plans). The average elapsed time of OOTSA and clinical planning were 59.2 ± 3.47 min and 76.53 ± 5.19 min. Conclusions: The plans created by OOTSA have been shown marginally better than the manual plans, especially in preserving OARs. In addition, the time of automatic treatment planning has shown a reduction compared to a manual planning process, and the variation of plan quality was greatly reduced. Although improvement on the algorithm is warranted, this proof-of-concept study has demonstrated that the proposed approach can be a practical solution for automatic planning. Advances in knowledge: The proposed method is novel in the emulation strategy of the physicists’ iterative operation during the planning process. Based on the existing optimizers, this method can be a simple yet effective solution for automated IMRT treatment planning.


2006 ◽  
Vol 33 (6Part23) ◽  
pp. 2294-2294 ◽  
Author(s):  
V Clark ◽  
I El Naqa ◽  
A Hope ◽  
G Suneja ◽  
J Bradley ◽  
...  

2016 ◽  
Vol 43 (6Part35) ◽  
pp. 3759-3759
Author(s):  
Wenzheng Feng

Sign in / Sign up

Export Citation Format

Share Document