scholarly journals Effect of elevated concentration of alkaline phosphatase on cardiac troponin I assays

2001 ◽  
Vol 15 (4) ◽  
pp. 175-177 ◽  
Author(s):  
Amitava Dasgupta ◽  
Leonard Chow ◽  
Alice Wells ◽  
Pradip Datta
2007 ◽  
Vol 30 (4) ◽  
pp. 426-427
Author(s):  
K. Jalinik ◽  
A. Hamela-Olkowska ◽  
P. Wlasienko ◽  
K. Czajkowski ◽  
J. Dangel

2018 ◽  
Vol 12 (1) ◽  
pp. 55-58 ◽  
Author(s):  
Rita Marinheiro ◽  
Pedro Amador ◽  
Leonor Parreira ◽  
Quitéria Rato ◽  
Rui Caria

Introduction: Since there are many manufacturers of cardiac troponin I assays, the true incidence of a false positive result is unknown. The authors report a case of an 18-year-old patient with previous history of recurrent myopericarditis and admitted to hospital twice again with a suspicious of myopericarditis. Conclusion: Troponin I was found to be a false positive and alkaline phosphatase interference was proved to have been the responsible for this.