Novel biodegradable calcium phosphate/polymer composite coating with adjustable mechanical properties formed by hydrothermal process for corrosion protection of magnesium substrate

2015 ◽  
Vol 104 (8) ◽  
pp. 1643-1657 ◽  
Author(s):  
Sara Kaabi Falahieh Asl ◽  
Sandor Nemeth ◽  
Ming Jen Tan
Friction ◽  
2020 ◽  
Author(s):  
Yilong Ren ◽  
Lin Zhang ◽  
Guoxin Xie ◽  
Zhanbo Li ◽  
Hao Chen ◽  
...  

AbstractSelf-lubricating polymer composite coatings, with tailorable tribological and mechanical properties, have been widely employed on mechanical parts to reduce friction and wear, which saves energy and improves the overall performance for applications such as aerospace satellite parts, shafts, gears, and bushings. The addition of functional fillers can overcome the limitations of single-polymer coatings and extend the service life of the coatings by providing a combination of low friction, high wear resistance, high load bearing, high temperature resistance, and high adhesion. This paper compares the heat resistance, and the tribological and mechanical properties of common polymer matrices, as well as the categories of functional fillers that improve the coating performance. Applicable scopes, process parameters, advantages, and limitations of the preparation methods of polymer coatings are discussed in detail. The tribological properties of the composite coatings with different matrices and fillers are compared, and the lubrication mechanisms are analyzed. Fillers reduce friction by promoting the formation of transfer films or liquid shear films. Improvement of the mechanical properties of the composite coatings with fillers of different morphologies is described in terms of strengthening and toughening mechanisms, including a stress transfer mechanism, shear yielding, crack bridging, and interfacial debonding. The test and enhancement methods for the adhesion properties between the coating and substrate are discussed. The coating adhesion can be enhanced through mechanical treatment, chemical treatment, and energy treatment of the substrate. Finally, we propose the design strategies for high-performance polymer composite coating systems adapted to specific operating conditions, and the limitations of current polymer composite coating research are identified.


A study review of aging polymer composite materials (PCM) under different heat-moisture conditions or water exposure with the sequential or parallel influence of static or cyclic loads in laboratory conditions is presented. The influence of tension and bending loads is compared. Conditions of the different load influence on parameters of carbon-reinforced plastics and glass-reinforced plastics are discussed. Equipment and units for climatic tests of PCM under loading are described. Simulation examples of indices of mechanical properties of PCM under the influence of environment and loads are shown.


A study review of aging polymer composite materials (PCM) under different heat-moisture conditions or water exposure with the sequential or parallel influence of static or cyclic loads in laboratory conditions is presented. The influence of tension and bending loads is compared. Conditions of the different load influence on parameters of carbon-reinforced plastics and glass-reinforced plastics are discussed. Equipment and units for climatic tests of PCM under loading are described. Simulation examples of indices of mechanical properties of PCM under the influence of environment and loads are shown.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Lijia Cheng ◽  
Tianchang Lin ◽  
Ahmad Taha Khalaf ◽  
Yamei Zhang ◽  
Hongyan He ◽  
...  

AbstractNowadays, artificial bone materials have been widely applied in the filling of non-weight bearing bone defects, but scarcely ever in weight-bearing bone defects. This study aims to develop an artificial bone with excellent mechanical properties and good osteogenic capability. Firstly, the collagen-thermosensitive hydrogel-calcium phosphate (CTC) composites were prepared as follows: dissolving thermosensitive hydrogel at 4 °C, then mixing with type I collagen as well as tricalcium phosphate (CaP) powder, and moulding the composites at 37 °C. Next, the CTC composites were subjected to evaluate for their chemical composition, micro morphology, pore size, Shore durometer, porosity and water absorption ability. Following this, the CTC composites were implanted into the muscle of mice while the 70% hydroxyapatite/30% β-tricalcium phosphate (HA/TCP) biomaterials were set as the control group; 8 weeks later, the osteoinductive abilities of biomaterials were detected by histological staining. Finally, the CTC and HA/TCP biomaterials were used to fill the large segments of tibia defects in mice. The bone repairing and load-bearing abilities of materials were evaluated by histological staining, X-ray and micro-CT at week 8. Both the CTC and HA/TCP biomaterials could induce ectopic bone formation in mice; however, the CTC composites tended to produce larger areas of bone and bone marrow tissues than HA/TCP. Simultaneously, bone-repairing experiments showed that HA/TCP biomaterials were easily crushed or pushed out by new bone growth as the material has a poor hardness. In comparison, the CTC composites could be replaced gradually by newly formed bone and repair larger segments of bone defects. The CTC composites trialled in this study have better mechanical properties, osteoinductivity and weight-bearing capacity than HA/TCP. The CTC composites provide an experimental foundation for the synthesis of artificial bone and a new option for orthopedic patients.