Wear in molded tibial inserts: Knee simulator study of H1900 and GUR1050 polyethylenes

2008 ◽  
Vol 85B (2) ◽  
pp. 314-319 ◽  
Author(s):  
Riichiro Tsukamoto ◽  
Paul Allen Williams ◽  
Hiromu Shoji ◽  
Kazuo Hirakawa ◽  
Kengo Yamamoto ◽  
...  
2009 ◽  
Vol 24 (7) ◽  
pp. 583-588 ◽  
Author(s):  
Sandra Utzschneider ◽  
Norbert Harrasser ◽  
Christian Schroeder ◽  
Farhad Mazoochian ◽  
Volkmar Jansson

2020 ◽  
Vol 38 (7) ◽  
pp. 1607-1616 ◽  
Author(s):  
Valentina Ngai ◽  
Joachim Kunze ◽  
Johannes Cip ◽  
Michel P. Laurent ◽  
Joshua J. Jacobs ◽  
...  

2013 ◽  
Vol 36 (1) ◽  
pp. 47-55 ◽  
Author(s):  
Carmen Zietz ◽  
Philipp Bergschmidt ◽  
Regina Lange ◽  
Wolfram Mittelmeier ◽  
Rainer Bader

2011 ◽  
Vol 7 (2) ◽  
pp. 710-715 ◽  
Author(s):  
J. Philippe Kretzer ◽  
Eike Jakubowitz ◽  
Jörn Reinders ◽  
Eva Lietz ◽  
Babak Moradi ◽  
...  

2021 ◽  
Vol 787 (1) ◽  
pp. 012116
Author(s):  
Wei Chen ◽  
Qian Zhao ◽  
Weiyuan Peng ◽  
Shengde Di ◽  
Chuanjiao Sun ◽  
...  
Keyword(s):  

Work ◽  
2021 ◽  
Vol 68 (s1) ◽  
pp. S37-S45
Author(s):  
Georg Burkhard ◽  
Tobias Berger ◽  
Erik Enders ◽  
Dieter Schramm

BACKGROUND: With the development of autonomous driving, the occupants’ comfort perception and their activities during the drive are becoming increasingly the focus of research. Especially in one of the first applications, a drive on a motorway, vertical dynamics play a major role. OBJECTIVE: To be able to robustly objectify ride comfort, better models need to be developed. Initial studies have shown, that the current ISO-2631 standard creates good results in the objectification and can be regarded as benchmark. METHODS: To increase the accuracy in objectification, an extended model with the occupants’ head as additional measuring point is introduced. Instead of the known frequency filters, weighting (k-factors) is used to differentiate possible excitations. For comparing the model with the ISO-2631, a simulator study with 5 excitations and 50 inattentive subjects is carried out. RESULTS: Evaluating the study with the ISO-2631, 3 out of 5 excitations indicate a significant difference between the occupant’s impression and the calculated comfort value. In comparison the extended model has no significant difference. CONCLUSION: The results further show, that inattentive occupants move their heads significantly more. By measuring accelerations of the head, the extended model creates equivalent or more accurate comfort values than the ISO-2631.


Sign in / Sign up

Export Citation Format

Share Document