Post silanization improves bond strength of translucent posts to flowable composite resins

2007 ◽  
Vol 82B (2) ◽  
pp. 320-324 ◽  
Author(s):  
Alberto Albaladejo ◽  
Raquel Osorio ◽  
Federica Papacchini ◽  
Cecilia Goracci ◽  
Manuel Toledano ◽  
...  
2013 ◽  
Vol 27 (7) ◽  
pp. 811-819 ◽  
Author(s):  
Maria Lobato ◽  
Javier Montero ◽  
Laura Ceballos ◽  
Raquel Oyagüe ◽  
Victoria Fuentes ◽  
...  

2012 ◽  
Vol 19 (2) ◽  
pp. 102
Author(s):  
Endang Wahyuningtyas ◽  
Suparyono Saleh ◽  
Sri Budi Barunawati

Latar Belakang. Resin komposit merupakan bahan pilihan untuk reparasi Gigi Tiruan Cekat porcelain fused to metal (PFM) Karena estetis baik dan manipulasi mudah. Tujuan penelitian ini adalah mengetahui perbedaan kekuatan geser perlekatan resin komposit pada permukaan logam Gigi Tiruan Cekat dengan menggunakan resin komposit jenis packable dan jenis flowable. Metode penelitian. Subjek penelitian berupa logam NiCr (Noritake, Japan) berbentuk silinder dengan diameter 10 mm dan tinggi 3 mm. Penelitian dibagi menjadi dua kelompok, masing-masing terdiri dari 10 subjek. Kelompok pertama reparasi dengan resin komposit packable (Z250™ 3M ESPE, USA) dan kelompok kedua reparasi dengan resin komposit flowable (Dyad flow, Kerr, USA). Permukaan subjek dikasari dengan wheel diamond bur, dietsa dengan asam fosfat 37 % (Scotchbond™, 3M ESPE, USA) kemudian dicuci dan dikeringkan, selanjutnya diaplikasikan silan (Rely X™ Ceramic Primer, 3M ESPE, USA) dan bonding (Adper™ Single Bond, 3M ESPE, USA). Permukaan kemudian dilapisi dengan resin komposit packable dan flowable, disinari selama 40 detik. Subjek penelitian direndam di dalam distilled water dan dimasukkan ke dalam incubator dengan suhu 37°C selama 7 hari. Uji kekuatan geser dilakukan dengan menggunakan Universal Testing Machine. Data dianalisis dengan uji t. hasil uji t menunjukkan terdapat perbedaan bermakna kekuatan geser reparasi gigi tiruan cekat pada permukaan logam (p<0,05). Kesimpulan penelitian ini adalah kekuatan geser reparasi pada permukaan logam dengan menggunakan resin komposit flowable yang mengandung bahan coupling agent lebih tinggi dibandingkan reparasi pada permukaan porselen dengan menggunakan resin komposit packable. Background. One of selected material by repairing the fixed partial denture was composite resin because of its good aesthetics and low manipulation. The aim. This research was aimed at identifying the differences of shear bond strength of composite resin on metal surface by using different composite resins, namely packable and flowable composite resins. Method. The research subjects were cylinders with 10 mm in diameter and 3 mm in height. The research subjects with metal material of NiCr (Noritke, Japan) involved two groups. The first group comprising 10 repair subjects with composite packable (Z250™, 3M ESPE, USA) and 10 repair subjects with flowable composite (Dyad flow, Kerr, USA). The surface of the subjects were roughned with wheel diamond bur and etched with 37% phosphate acid (Scotbond™, 3M ESPE, USA) were applied. The surface was then coated with packable and flowable composite resins and light-cured for 40 seconds. The research subjects were immersed in distilled water and put into the incubator at temperature of 37°C for 7 days. The shear bond strength test was conducted using the Universal Testing Machine. Data were analyzed using t-test. The result. The research result showed that there were differences of shear bond strength of repair between packable and flowable composite resins. The result of t-test indicated significant diffrences on metal surface (p<0,05). The conclusion of this research is that shear bond strength of repair with flowable composite which contain coupling agent has higher shear bond strength than that of packable composite resin.


2019 ◽  
Vol 4 (1) ◽  
pp. 16-25
Author(s):  
Steven Tanjung ◽  
Rudy Djuanda ◽  
Angela Evelyna

Restoration is a treatment to restore the structure of missing dental hard tissue due to caries. Flowable composite has good adaptability to the cavity wall so that it is widely used as an intermediate layer. Composite resins require an adhesive system to bond chemically with dental hard tissue. Self - adhering flowable composite combining etching, priming, and adhesive in one flowable package. This study was conducted with the aim to determine the difference in shear bond strength between Self – adhering flowable composite and flowable composite with self – etch adhesive system on dentine. The number of samples used was 38 pieces. After dentin was prepared and fixed, samples was divided into 2 groups, each group consisting of 19 samples. First group was applied with self – adhering flowable composite, second group was applied with flowable composite with self – etch adhesive system. Samples was immersed in pH 6.8 normal saline and stored for 24 hours, then dried and shear bond strength was tested using a universal testing machine. The data obtained were analyzed using independent t – test. The statistical analysis using independent t – test showed that there were significant differences in the shear bond strength between the two groups, p=0,000 (p<0.05). The study concluded that there is difference of shear bond strength between self – adhering flowable composite and flowable composite with self – etch adhesive system on dentine.


2016 ◽  
Vol 41 (3) ◽  
pp. 322-327
Author(s):  
Mohamed H. Abdelrahman ◽  
Elsayed M. Mahmoud ◽  
Mona M. Ghoneim ◽  
Adel A. Kammar

2017 ◽  
Vol 16 ◽  
pp. 1-8 ◽  
Author(s):  
Leonardo Fernandes da Cunha ◽  
Ana Beatriz Franco Fernandes ◽  
Amanda Mahammad Mushashe ◽  
Gisele Maria Correr ◽  
Carla Castiglia Gonzaga

The objective of this study was to evaluate the mechanical properties of two bis-acryl interim resin materials, such as color stability, flexural strength and shear bond strength to flowable composite resin, simulating clinical situations when this material has to be used for repair as add-on. Two shades of two bis-acryl interim resin materials [Structur 2 SC (shades Bleach and A2); Protemp 4 (shades A1 and A2)] were evaluated. Discs (5 x 1 mm) were fabricated and baseline color was determined after 1 h. Ten specimens were immersed at 37oC in solutions of distilled water (control) and cola-based soft drink (Coca-Cola). Color measurements were performed with a spectrophotometer using CIELab parameters. Color readings were again measured after 2 hours, 4 hours, 24 hours and 7 days. Flexural strength was determined using the three-point bending test (10 x 1 x 2 mm) on a universal testing machine (0.5 mm/min) (n = 10). Discs of bis-acryl resin were embedded in acrylic resin, planned and distributed in 2 groups: G1 - Filtek Z350 Flow/Protemp4 and G2 - Grandio SO Flow/Structure 3 (n = 15). Cylinders (3.5 x 2 mm) were made with the flowable composite resins and polymerized for 20 s. The specimens were stored in distilled water at 37oC for 24 h and subjected to shear bond strength test. Data were analyzed using one-way ANOVA and Tukey’s test ( = 0.05). ΔE values were higher for Structur Bleach (3.08)a compared with Protemp 4 (shade A1, 2.22)b (shade A2, 2.25)b. There were no significant differences between Structur Bleach and Structur A2 (2.62)ab. Coca-Cola presented higher ΔE values (3.08)a than (2.00)b. Regarding time, ΔE values increased from 1.84a after 2 h to 2.31b after 4 h. The higher values were observed after 24 h and 7 days (2.93c and 3.09d, respectively). No significant differences were observed for the flexural strength of Structur (22.05 MPa)a and Protemp 4 (19.01 MPa)a. The repairs executed with Structur/Grandio flow (9.21 MPa)a were similar to those performed with Protemp 4/Z350XT flow (10.71 MPa)a. It can be concluded that the two bis-acyl resins evaluated showed similar physical and mechanical properties.


2020 ◽  
Vol 14 (03) ◽  
pp. 456-461
Author(s):  
Rayhaneh Khalesi ◽  
Mahdi Abbasi ◽  
Zahra Shahidi ◽  
Masoumeh Hasani Tabatabaei ◽  
Zohreh Moradi

Abstract Objectives Advances in laboratory composites and their high wear resistance and fracture toughness have resulted in their growing popularity and increasing use for dental restorations. This study sought to assess the fracture toughness of three indirect composites bonded to dental substrate and polyether ether ketone (PEEK) polymer. Materials and Methods This in vitro study was conducted on two groups of dental and polymer substrates. Each substrate was bonded to three indirect composite resins. Sixty blocks (3 × 3 × 12 mm) were made of sound bovine anterior teeth and PEEK polymer. Sixty blocks (3 × 3 × 12 mm) were fabricated of CRIOS (Coltene, Germany), high impact polymer composite (HIPC; Bredent, Germany), and GRADIA (Indirect; GC, Japan) composite resins. Composites were bonded to dentin using Panavia F 2.0 (Kuraray, Japan). For bonding to PEEK, Combo.lign (Bredent) and Visio.Link (Bredent) luting cements were used. In all samples, a single-edge notch was created by a no. 11 surgical blade at the interface. The samples were subjected to 3,500 thermal cycles, and their fracture toughness was measured in a universal testing machine (Zwick/Roell, Germany) by application of four-point flexural load. Statistical Analysis Data were analyzed using one-way analysis of variance, Kruskal–Wallis. Results The fracture toughness of CRIOS–PEEK interface was significantly higher than HIPC–PEEK. The fracture toughness of GRADIA–PEEK was not significantly different from that of HIPC and CRIOS. The fracture toughness of GRADIA–dentin was significantly higher than HIPC–dentin. Conclusion Considering the limitations of this study, GRADIA has the highest bond strength to dentin, while CRIOS shows the highest bond strength to PEEK.


2002 ◽  
Vol 27 (2) ◽  
pp. 142 ◽  
Author(s):  
Suk-Ho Kang ◽  
Oh-young Kim ◽  
Myung-Hwan Oh ◽  
Byeong-Hoon Cho ◽  
Chung-Moon Um ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document